Description
[{“name”:”Item”,”normalizedValue”:”Metal Clad Building Cable”,”rank”:1,”value”:”Metal Clad Building Cable”},{“name”:”Trade Designation”,”normalizedValue”:”MC”,”rank”:2,”value”:”MC”},{“name”:”Wire Size”,”normalizedValue”:”12 AWG”,”rank”:3,”value”:”12 AWG”},{“name”:”Conductor Material”,”normalizedValue”:”Copper”,”rank”:4,”value”:”Copper”},{“name”:”Number of Conductors”,”normalizedValue”:”2C with Ground”,”rank”:5,”value”:”2C with Ground”},{“name”:”Wire Color”,”normalizedValue”:”Black/Green/White”,”rank”:6,”value”:”Black/Green/White”},{“name”:”Jacket Color”,”normalizedValue”:”Silver”,”rank”:7,”value”:”Silver”},{“name”:”Jacket Material”,”normalizedValue”:”Aluminum”,”rank”:8,”value”:”Aluminum”},{“name”:”Conductor Design”,”normalizedValue”:”Stranded”,”rank”:10,”value”:”Stranded”},{“name”:”Insulation Material”,”normalizedValue”:”PVC”,”rank”:11,”value”:”PVC”},{“name”:”Voltage”,”normalizedValue”:”600V”,”rank”:12,”value”:”600V”},{“name”:”Length”,”normalizedValue”:”100 ft”,”rank”:13,”value”:”100 ft”},{“name”:”Temp. Rating”,”normalizedValue”:”-14 Degrees to 90 Degrees C Dry”,”rank”:14,”value”:”-14 Degrees to 90 Degrees C Dry”},{“name”:”Standards”,”normalizedValue”:”UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems”,”rank”:15,”value”:”UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems”},{“name”:”Nominal Outside Dia.”,”normalizedValue”:”0.494 in”,”value”:”0.494 in”},{“name”:”Max. Amps”,”normalizedValue”:”20″,”value”:”20″},{“name”:”Application”,”normalizedValue”:”Commercial, Industrial, Institutional, Multiresidential Buildings”,”value”:”Commercial, Industrial, Institutional, Multiresidential Buildings”},{“name”:”Stranding”,”normalizedValue”:”19″,”value”:”19″},{“name”:”Conductor Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Packaging”,”normalizedValue”:”Coil”,”value”:”Coil”},{“name”:”Overall Length”,”normalizedValue”:”100 ft”,”value”:”100 ft”},{“name”:”Construction”,”normalizedValue”:”ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.”,”value”:”ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.”},{“name”:”Insulation Thickness (Mils)”,”normalizedValue”:”15 mil”,”value”:”15mils”},{“name”:”Applications”,”normalizedValue”:”ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.”,”value”:”ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.”},{“name”:”Number of Ground Conductors”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Trade Designation – Conductors”,”normalizedValue”:”THHN, THWN”,”value”:”THHN, THWN”},{“name”:”Nominal Outside Diameter”,”normalizedValue”:”1/2 in”,”value”:”0.5 in”},{“name”:”Conductor Insulation Color”,”normalizedValue”:”White, Black”,”value”:”Black, White”},{“name”:”Grounding Conductor Material”,”normalizedValue”:”Copper”,”value”:”Copper”},{“name”:”Grounding Conductor Insulation Color”,”normalizedValue”:”Green”,”value”:”Green”},{“name”:”Temperature Rating – Maximum Dry”,”normalizedValue”:”194 deg F”,”value”:”194 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.