Description
[{“name”:”Item”,”normalizedValue”:”Flanged Receptacle”,”rank”:1,”value”:”Flanged Receptacle”},{“name”:”Voltage”,”normalizedValue”:”600V AC”,”rank”:3,”value”:”600V AC”},{“name”:”Color”,”normalizedValue”:”Yellow”,”rank”:5,”value”:”Yellow”},{“name”:”Number of Poles”,”normalizedValue”:”3-Pole”,”rank”:6,”value”:”3-Pole”},{“name”:”Phase”,”normalizedValue”:”Multi Phase”,”rank”:8,”value”:”Multi Phase”},{“name”:”IP Rating”,”normalizedValue”:”IP44″,”value”:”IP44″},{“name”:”Material”,”normalizedValue”:”zinc plated Steel”,”value”:”zinc plated Steel”},{“name”:”Flange Material”,”normalizedValue”:”Steel Weldment”,”value”:”Steel Weldment”},{“name”:”Special Features”,”normalizedValue”:”Molded In or Stamped On”,”value”:”Molded In or Stamped On”},{“name”:”Standards”,”normalizedValue”:”Certified for current interrupting at full rated current; UL/CSA”,”value”:”Certified for current interrupting at full rated current; UL/CSA”},{“name”:”Application”,”normalizedValue”:”Heavy Duty Industrial”,”value”:”Heavy Duty Industrial”},{“name”:”Spring Material”,”normalizedValue”:”Bronze”,”value”:”.032″ (.8) Bronze”},{“name”:”Operating Temp.”,”normalizedValue”:”Maximum Continuous 75A Deg C Minimum -40A Deg C (w/o impact)”,”value”:”Maximum Continuous 75A Deg C Minimum -40A Deg C (w/o impact)”},{“name”:”Temp. Rise”,”normalizedValue”:”Max 30C temperature rise at full rated current after 50 cycles of overload at 150% of rated current at a power factor of .75.”,”value”:”Max 30C temperature rise at full rated current after 50 cycles of overload at 150% of rated current at a power factor of .75.”},{“name”:”Wire Size”,”normalizedValue”:”#6 AWG; #8 AWG – #4 AWG solid or stranded copper wire only.”,”value”:”#6 AWG; #8 AWG – #4 AWG solid or stranded copper wire only.”},{“name”:”Terminal Designations”,”normalizedValue”:”Terminals identified in accordance with UL 498 (X, Y, Z, White, Green)”,”value”:”Terminals identified in accordance with UL 498 (X, Y, Z, White, Green)”},{“name”:”Flammability”,”normalizedValue”:”UL 94 VO for Receptacles and Inlets. HB or better for Plugs and Connectors.”,”value”:”UL 94 VO for Receptacles and Inlets. HB or better for Plugs and Connectors.”},{“name”:”Lock Type”,”normalizedValue”:”Hubbellock”,”value”:”Hubbellock”},{“name”:”Weight (Lbs.)”,”normalizedValue”:”2.05″,”value”:”2.05″},{“name”:”Dielectric Strength”,”normalizedValue”:”Withstands 2,000V minimum”,”value”:”Withstands 2,000V minimum”},{“name”:”Amperage Rating”,”normalizedValue”:”60 A”,”value”:”60 A”},{“name”:”Performance”,”normalizedValue”:”Electrical – Current Interrupting – Certified for current interrupting at full rated current Electrical – Dielectric Voltage – 2,000V minimum Environmental – Flammability – UL 94 V0 Environmental – Moisture Resistance – IP30 Suitability Environmental – Operating Temperatures – Maximum Continuous 75°C Minimum -40°C (w/o impact) Mechanical – Terminal Accomodation – #8 AWG – #4 AWG solid or stranded copper wire only. Mechanical – Terminal Identification – Terminals identified in accordance with UL 498″,”value”:”Electrical – Current Interrupting – Certified for current interrupting at full rated currentnElectrical – Dielectric Voltage – 2,000V minimumnEnvironmental – Flammability – UL 94 V0nEnvironmental – Moisture Resistance – IP30 SuitabilitynEnvironmental – Operating Temperatures – Maximum Continuous 75°C Minimum -40°C (w/o impact)nMechanical – Terminal Accomodation – #8 AWG – #4 AWG solid or stranded copper wire only.nMechanical – Terminal Identification – Terminals identified in accordance with UL 498″},{“name”:”Length”,”normalizedValue”:”4.12 in”,”value”:”4.12 in”},{“name”:”Current / Amperage Rating”,”normalizedValue”:”60 A”,”value”:”60 A”},{“name”:”Type”,”normalizedValue”:”Flanged Receptacle”,”value”:”Flanged Receptacle”},{“name”:”Display Size”,”normalizedValue”:”Standard Sized Product”,”value”:”Standard Sized Product”},{“name”:”Current Rating”,”normalizedValue”:”60 A”,”value”:”60 A”},{“name”:”Height”,”normalizedValue”:”4.53 in”,”value”:”4.53 in”},{“name”:”Voltage Rating Description”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Industry Standard(s)”,”normalizedValue”:”Certified to CSA Standard Listed to UL Standard”,”value”:”Certified to CSA StandardnListed to UL Standard”},{“name”:”Number Of Wires”,”normalizedValue”:”4-Wire”,”value”:”4-Wire”},{“name”:”Width”,”normalizedValue”:”2.88 in”,”value”:”2.88 in”},{“name”:”Environmental Conditions”,”normalizedValue”:”Indoor Dry Unless Protected By Additional Means”,”value”:”Indoor Dry Unless Protected By Additional Means”},{“name”:”Connectivity”,”normalizedValue”:”Screw Terminals”,”value”:”Screw Terminals”},{“name”:”Operating Temperature”,”normalizedValue”:”Maximum continuous 75°C and minimum -40°C without Impact”,”value”:”Maximum continuous 75°C and minimum -40°C without Impact”},{“name”:”Material – Mounting Hardware”,”normalizedValue”:”Screw Mounting”,”value”:”Screw Mounting”},{“name”:”Dimensions”,”normalizedValue”:”4.12 in x 2.88 in x 4.53 in”,”value”:”4.12 in x 2.88 in x 4.53 in”},{“name”:”Item Type”,”normalizedValue”:”60A Hubbellock® Receptacle”,”value”:”60A Grounding Hubbellock® Flanged Receptacle”},{“name”:”OEM Brand Name”,”normalizedValue”:”Hubbell Wiring Device-Kellems”,”value”:”Hubbell Wiring Device-Kellems”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.