Description
[{“name”:”Item”,”normalizedValue”:”Interface plug-in relay – Zelio RSB – 1″,”rank”:1,”value”:”Interface plug-in relay – Zelio RSB – 1″},{“name”:”Standards”,”normalizedValue”:”UL 508; EN/IEC 61810-1; CSA C22.2 No 14″,”rank”:17,”value”:”UL 508; EN/IEC 61810-1; CSA C22.2 No 14″},{“name”:”Average Coil Resistance”,”normalizedValue”:”400 Ohm AC 20°C +/- 15%”,”value”:”400 Ohm AC 20°C +/- 15%”},{“name”:”Dielectric Strength”,”normalizedValue”:”1000 V AC between contacts; 2500 V AC between poles; 5000 V AC between coil and contact”,”value”:”1000 V AC between contacts; 2500 V AC between poles; 5000 V AC between coil and contact”},{“name”:”Rated Operational Current”,”normalizedValue”:”16 A AC-1/DC-1) NO IEC; 8 A AC-1/DC-1) NC IEC”,”value”:”16 A AC-1/DC-1) NO IEC; 8 A AC-1/DC-1) NC IEC”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles, 16 A at 250 V, AC-1 NO; 100000 cycles, 8 A at 250 V, AC-1 NC”,”value”:”100000 cycles, 16 A at 250 V, AC-1 NO; 100000 cycles, 8 A at 250 V, AC-1 NC”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”3.6 kV IEC 61000-4-5″,”value”:”3.6 kV IEC 61000-4-5″},{“name”:”Contact Operation”,”normalizedValue”:”Standard”,”value”:”Standard”},{“name”:”Minimum Switching Capacity”,”normalizedValue”:”300 mW 5 mA”,”value”:”300 mW 5 mA”},{“name”:”Operating Rate”,”normalizedValue”:”Less than or Equal to 600 cycles/hour under load; Less than or Equal to 72000 cycles/hour no-load”,”value”:”Less than or Equal to 600 cycles/hour under load; Less than or Equal to 72000 cycles/hour no-load”},{“name”:”Control Type”,”normalizedValue”:”without push-button”,”value”:”Without push-button”},{“name”:”Resistive Rated Load”,”normalizedValue”:”16 A 250 V AC; 16 A 28 V DC”,”value”:”16 A 250 V AC; 16 A 28 V DC”},{“name”:”Operating Position”,”normalizedValue”:”any position”,”value”:”Any position”},{“name”:”Shock Resistance”,”normalizedValue”:”10 gn 11 ms) not operating EN/IEC 60068-2-27; 5 gn 11 ms) in operation EN/IEC 60068-2-27″,”value”:”10 gn 11 ms) not operating EN/IEC 60068-2-27; 5 gn 11 ms) in operation EN/IEC 60068-2-27″},{“name”:”Conventional Enclosed Thermal Current”,”normalizedValue”:”16 A -40 to 104°F (-40 to 40°C)”,”value”:”16 A -40 to 104°F (-40 to 40°C)”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”19.2 to 26.4 V AC 50 Hz; 20.4 to 26.4 V AC 60 Hz”,”value”:”19.2 to 26.4 V AC 50 Hz; 20.4 to 26.4 V AC 60 Hz”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40 to 158°F AC, -40 to 185°F DC”,”value”:”-40 to 158°F (-40 to 70°C) AC); -40 to 185°F (-40 to 85°C) DC)”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40 to 185°F”,”value”:”-40 to 185°F (-40 to 85°C)”},{“name”:”Average Coil Consumption”,”normalizedValue”:”0.75 VA AC 60 Hz”,”value”:”0.75 VA AC 60 Hz”},{“name”:”Protection Category”,”normalizedValue”:”RT I”,”value”:”RT I”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP40 conforming to EN/IEC 60529″,”value”:”IP40 conforming to EN/IEC 60529″},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, GOST”,”value”:”UL; GOST; CSA”},{“name”:”Status LED”,”normalizedValue”:”Without”,”value”:”Without”},{“name”:”Product Or Component Type”,”normalizedValue”:”Plug-in relay”,”value”:”Plug-in relay”},{“name”:”Mechanical Durability”,”normalizedValue”:”30,000,000 cycle”,”value”:”30000000 cycles”},{“name”:”Contacts Material”,”normalizedValue”:”Silver alloy”,”value”:”Silver alloy (Ag/Ni)”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”24 V AC”,”value”:”24 V AC”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”300 V DC, 400 V AC”,”value”:”300 V DC; 400 V AC”},{“name”:”Drop-Out Voltage Threshold”,”normalizedValue”:”Greater than or Equal to 0.15 Uc AC”,”value”:”Greater than or Equal to 0.15 Uc AC”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”400 V EN/IEC 60947″,”value”:”400 V EN/IEC 60947″},{“name”:”Vibration Resistance”,”normalizedValue”:”+/- 1 mm 10 to 55 Hz)EN/IEC 60068-2-6″,”value”:”+/- 1 mm 10 to 55 Hz)EN/IEC 60068-2-6″},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Device Presentation”,”normalizedValue”:”complete product”,”value”:”Complete product”},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”4000 VA AC; 448 W DC”,”value”:”4000 VA AC; 448 W DC”},{“name”:”Contact Type and Composition”,”normalizedValue”:”O, 1 C”,”value”:”1 C/O”},{“name”:”Operating Time”,”normalizedValue”:”10 msec (between coil de-energisation and making of the Off-delay contact), 12 msec (between coil energisation and making of the On-delay contact)”,”value”:”10 ms between coil de-energisation and making of the Off-delay contact; 12 ms between coil energisation and making of the On-delay contact”},{“name”:”Shape Of Pin”,”normalizedValue”:”Flat”,”value”:”Flat”},{“name”:”Series Name”,”normalizedValue”:”interface relay”,”value”:”Interface relay”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”5 V”,”value”:”5 V”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.