Inline Draft Inducer Blower For 4 in x 12-3/4 in Cut Out, 115V, 1/4 hp

$618,99

Draft Inducer, Application Boilers, Furnaces, Water Heaters, For Fuel Type Natural Gas, Oil, For Appliance Type Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters, Maximum Vent Pipe Diameter 12 in, Minimum Vent Pipe Diameter 8 in, Maximum Heater BTU Input for Gas Appliance 1,330,000 BtuH, Maximum Heater BTU Input for Oil Appliance 1,100,000 BtuH, Nameplate Voltage 115V AC, Current 5.4 A, Frequency 60 Hz, Maximum Static Pressure 1/8 in wc

9999 in stock

SKU: GRG0357052 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Draft Inducer”,”rank”:2,”value”:”Draft Inducer”},{“name”:”Type”,”normalizedValue”:”In-line”,”rank”:3,”value”:”In-line”},{“name”:”Voltage”,”normalizedValue”:”115 V”,”rank”:4,”value”:”115″},{“name”:”Depth (In.)”,”normalizedValue”:”8-3/4″,”rank”:5,”value”:”8 3/4 in”},{“name”:”Cut Out Required”,”normalizedValue”:”4\” x 12-3/4\””,”rank”:6,”value”:”4\” x 12-3/4\””},{“name”:”HP”,”normalizedValue”:”1/4 hp”,”rank”:7,”value”:”1/4 hp”},{“name”:”Construction Material”,”normalizedValue”:”Aluminized Steel”,”rank”:8,”value”:”Aluminized Steel”},{“name”:”Amps”,”normalizedValue”:”5.4″,”rank”:9,”value”:”5.4A”},{“name”:”Includes”,”normalizedValue”:”Fastening Band”,”rank”:10,”value”:”Fastening Band”},{“name”:”Remarks”,”normalizedValue”:”View Catalog Page for Selection Criteria”,”rank”:11,”value”:”View Catalog Page for Selection Criteria”},{“name”:”Height (In.)”,”normalizedValue”:”14-1/2″,”rank”:12,”value”:”14 1/2 in”},{“name”:”Vent Pipe Dia. (In.)”,”normalizedValue”:”8 to 12\””,”rank”:13,”value”:”8 to 12\””},{“name”:”For Use With Mfr. Model Number”,”normalizedValue”:”PS1505″,”rank”:14,”value”:”PS1505″},{“name”:”Width (In.)”,”normalizedValue”:”13-1/2″,”rank”:18,”value”:”13 1/2 in”},{“name”:”Application”,”normalizedValue”:”Furnaces, Water Heaters, Boilers”,”rank”:19,”value”:”Boilers, Furnaces, Water Heaters”},{“name”:”RPM”,”normalizedValue”:”1,725″,”rank”:24,”value”:”1725″},{“name”:”Overload Protection”,”normalizedValue”:”Thermal”,”rank”:32,”value”:”Thermal”},{“name”:”CFM @ 1.000-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Heater Btu Input @ 530 (F)”,”normalizedValue”:”1,100,000 1,100,000 840,000 400,000″,”value”:”1,100,000 1,100,000 840,000 400,000″},{“name”:”CFM @ 390 Deg. (F)”,”normalizedValue”:”603,653,615,357″,”value”:”603653615357″},{“name”:”Duct Temp. Deg. (F)”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 1.40-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”SP @ 270 Deg. (F)”,”normalizedValue”:”0.1250.1350.1400.128″,”value”:”0.1250.1350.1400.128″},{“name”:”SP @ 390 Deg. (F)”,”normalizedValue”:”0.1430.1500.1450.115″,”value”:”0.1430.1500.1450.115″},{“name”:”CFM @ 0.700-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”SP @ 530 Deg. (F)”,”normalizedValue”:”0.1470.1480.1360.100″,”value”:”0.1470.1480.1360.100″},{“name”:”BtuH Input”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 530 Deg. (F)”,”normalizedValue”:”566,566,440,211″,”value”:”566566440211″},{“name”:”Heater Btu Input @ 270 (F)”,”normalizedValue”:”900,000 1,110,000 1,250,000 1,030,000″,”value”:”900,000 1,110,000 1,250,000 1,030,000″},{“name”:”CFM @ 0.000-In. SP”,”normalizedValue”:””,”value”:”N/A”},{“name”:”CFM @ 0.500-In. SP”,”normalizedValue”:”N/A.”,”value”:”N/A.”},{“name”:”CFM @ 270 Deg. (F)”,”normalizedValue”:”590,765,850,710″,”value”:”590765850710″},{“name”:”Heater Btu Input @ 390 (F)”,”normalizedValue”:”1,200,000 1,330,000 1,260,000 710,000″,”value”:”1,200,000 1,330,000 1,260,000 710,000″},{“name”:”Overall Height”,”normalizedValue”:”14-1/2 in”,”value”:”14 1/2 in”},{“name”:”Overall Width”,”normalizedValue”:”13-1/2 in”,”value”:”13 1/2 in”},{“name”:”Maximum Vent Pipe Diameter”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”Minimum Heat Input”,”normalizedValue”:”400,000 Btu (Oil/Barometric), 710,000 Btu (Gas/Barometric), 900,000 Btu (Gas/Draft Hood)”,”value”:”400,000 Btu (Oil/Barometric), 710,000 Btu (Gas/Barometric), 900,000 Btu (Gas/Draft Hood)”},{“name”:”Minimum Vent Pipe Diameter”,”normalizedValue”:”8 in”,”value”:”8 in”},{“name”:”Cutout Size”,”normalizedValue”:”4 in x 12 3/4 in”,”value”:”4 in x 12 3/4 in”},{“name”:”Maximum Heater BTU Input for Gas Appliance”,”normalizedValue”:”1,330,000 BtuH”,”value”:”1,330,000 BtuH”},{“name”:”Maximum Heater BTU Input for Oil Appliance”,”normalizedValue”:”1,100,000 BtuH”,”value”:”1,100,000 BtuH”},{“name”:”Airflow at Temperature”,”normalizedValue”:”566 cfm @ 530 Degrees F, 566 cfm @ 530 Degrees F, 440 cfm @ 530 Degrees F, 211 cfm @ 530 Degrees F, 590 cfm @ 270 Degrees F, 765 cfm @ 270 Degrees F, 850 cfm @ 270 Degrees F, 710 cfm @ 270 Degrees F, 603 cfm @ 390 Degrees F, 653 cfm @ 390 Degrees F, 615 cfm @ 390 Degrees F, 357 cfm @ 390 Degrees F”,”value”:”566 cfm @ 530 Degrees F, 566 cfm @ 530 Degrees F, 440 cfm @ 530 Degrees F, 211 cfm @ 530 Degrees F, 590 cfm @ 270 Degrees F, 765 cfm @ 270 Degrees F, 850 cfm @ 270 Degrees F, 710 cfm @ 270 Degrees F, 603 cfm @ 390 Degrees F, 653 cfm @ 390 Degrees F, 615 cfm @ 390 Degrees F, 357 cfm @ 390 Degrees F”},{“name”:”Overall Depth”,”normalizedValue”:”11-3/4 in”,”value”:”11 3/4 in”},{“name”:”Maximum Heat Input”,”normalizedValue”:”1,100,000 Btu (Oil/Barometric), 1,250,000 Btu (Gas/Draft Hood), 1,330,000 Btu (Gas/Barometric)”,”value”:”1,100,000 Btu (Oil/Barometric), 1,250,000 Btu (Gas/Draft Hood), 1,330,000 Btu (Gas/Barometric)”},{“name”:”Current”,”normalizedValue”:”5.4 A”,”value”:”5.4 A”},{“name”:”Power Consumption”,”normalizedValue”:”0.2 HP”,”value”:”0.2 hp”},{“name”:”Nameplate Voltage”,”normalizedValue”:”115V AC”,”value”:”115V AC”},{“name”:”For Appliance Type”,”normalizedValue”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”,”value”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”},{“name”:”Maximum Static Pressure”,”normalizedValue”:”0.125 in wc”,”value”:”1/8 in wc”},{“name”:”For Fuel Type”,”normalizedValue”:”Natural Gas, Oil”,”value”:”Natural Gas, Oil”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Blower Type”,”normalizedValue”:”Induced Draft Blower”,”value”:”Induced Draft Blower”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Inline Draft Inducer Blower For 4 in x 12-3/4 in Cut Out, 115V, 1/4 hp”