Ignition Module

$176,99

Ignition Control, Product Type Ignition Control, Maximum Operating Temperature 175 Degrees F, Minimum Operating Temperature -40 Degrees F, Lock Out Time 1 min, Pre-Purge Time 5 min, Number of Retries 3, Main Valve Current Output 1.5 A, Flame Sensor Current Output 0.7 mA, Ignition Cycle Time 60 seconds, Automatic Reset Time Not Applicable, Compatible with Series Universal

9999 in stock

SKU: GRG2500565 Category:

Description

[{“name”:”Type”,”normalizedValue”:”Lockout, 1 Rod or 2 Rod Sensing”,”value”:”Lockout, 1 Rod or 2 Rod Sensing”},{“name”:”Item”,”normalizedValue”:”Ignition Control”,”value”:”Ignition Control”},{“name”:”Retries”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Control Volts”,”normalizedValue”:”24 V”,”value”:”24 V”},{“name”:”Gas Type”,”normalizedValue”:”LP”,”value”:”LP”},{“name”:”Amps AC”,”normalizedValue”:”1.5 A”,”value”:”1.5 A”},{“name”:”Electrical Connections”,”normalizedValue”:”1/4 in (Spades and Molex plug)”,”value”:”1/4 in Spades and Molex plug”},{“name”:”Includes”,”normalizedValue”:”780-845 Module, Mounting Kit, Wiring Harness”,”value”:”780-845 Module, Mounting Kit, Wiring Harness”},{“name”:”For Use With”,”normalizedValue”:”Residential, Commercial Heating Equipment, Universal Replacement Spark Control Designed For Maximum Compatibility”,”value”:”Residential, Commercial Heating Equipment, Universal Replacement Spark Control Designed For Maximum Compatibility”},{“name”:”Operation Description”,”normalizedValue”:”Lockout Feature To Shut Off All Gas To The Furnace, Should Pilot Ignition Fail To Occur After A Predetermined Time Period. The 780-002 Provides 3 Tries For Ignition, Each Ignition Period Is 90 Seconds Followed By A 6 Minute Time Delay Between Ignition Attempts. After 3 Tries If No Pilot Flame Is Sensed, Unit Goes Into Lockout And Must Be Reset At The Thermostat.”,”value”:”Lockout Feature To Shut Off All Gas To The Furnace, Should Pilot Ignition Fail To Occur After A Predetermined Time Period. The 780-002 Provides 3 Tries For Ignition, Each Ignition Period Is 90 Seconds Followed By A 6 Minute Time Delay Between Ignition Attempts. After 3 Tries If No Pilot Flame Is Sensed, Unit Goes Into Lockout And Must Be Reset At The Thermostat.”},{“name”:”Prepurge Time (Sec.)”,”normalizedValue”:”360″,”value”:”360 sec”},{“name”:”Voltage”,”normalizedValue”:”24 V”,”value”:”24″},{“name”:”Electrical Ratings”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Standards”,”normalizedValue”:”cCSAus”,”value”:”cCSAus”},{“name”:”Product Type”,”normalizedValue”:”Ignition Control”,”value”:”Ignition Control”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 Degrees F”,”value”:”-40 Degrees F”},{“name”:”For Fuel Type”,”normalizedValue”:”LP”,”value”:”LP”},{“name”:”Automatic Reset Time”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Compatible with Series”,”normalizedValue”:”Universal”,”value”:”Universal”},{“name”:”Maximum Input Current”,”normalizedValue”:”1.5 A”,”value”:”1.5 A”},{“name”:”Thermostat Anticipator Setting”,”normalizedValue”:”Thermostat Anticipator”,”value”:”Thermostat Anticipator”},{“name”:”Number of Retries”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Compatible with Brand”,”normalizedValue”:”Airflow, Alco Food, Binet, Bradford-White, Cabell, Carrier, Chamberlain, Ed PAC/AC, Edison, Eisco Limited, Electro-Home, Electro-Therm, Elixier, Elkay, Ellis \u0026 Watts, Elmet, Embassy Industries, General Steel Wares, Honeywell, International, Johnson Controls, Johnstone Supply, Kool-Fire, Leemco, Lennox, Robertshaw, Uni-Line, Westward”,”value”:”Airflow, Alco Food, Binet, Bradford-White, Cabell, Carrier, Chamberlain, Ed PAC/AC, Edison, Eisco Limited, Electro-Home, Electro-Therm, Elixier, Elkay, Ellis \u0026 Watts, Elmet, Embassy Industries, General Steel Wares, Honeywell, International, Johnson Controls, Johnstone Supply, Kool-Fire, Leemco, Lennox, Robertshaw, Uni-Line, Westward”},{“name”:”Input Voltage”,”normalizedValue”:”24 V AC”,”value”:”24V AC”},{“name”:”Series”,”normalizedValue”:”780″,”value”:”780″},{“name”:”Flame Sensor Current Output”,”normalizedValue”:”0.7 mA”,”value”:”0.7 mA”},{“name”:”Replacement Type”,”normalizedValue”:”Universal”,”value”:”Universal”},{“name”:”Lock Out Time”,”normalizedValue”:”1 min”,”value”:”1 min”},{“name”:”Pre-Purge Time”,”normalizedValue”:”5 min”,”value”:”5 min”},{“name”:”Control Voltage”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Electrical Connection Type”,”normalizedValue”:”1/4 in Spade Terminals, Molex Plug”,”value”:”1/4 in Spade Terminals, Molex Plug”},{“name”:”Ignition Cycle Time”,”normalizedValue”:”60 seconds”,”value”:”60 seconds”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”175 deg F”,”value”:”175 Degrees F”},{“name”:”Main Valve Current Output”,”normalizedValue”:”1.5 A”,”value”:”1.5 A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Ignition Module”