Description
[{“name”:”Item”,”normalizedValue”:”IEC Power Contactor”,”rank”:1,”value”:”IEC Power Contactor”},{“name”:”Full Load Amps-Inductive”,”normalizedValue”:”17 A”,”rank”:2,”value”:”17 A”},{“name”:”Full Load Amps-Resistive”,”normalizedValue”:”40 A”,”rank”:3,”value”:”40 A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:4,”value”:”3″},{“name”:”Coil Volts”,”normalizedValue”:”110 V AC”,”rank”:5,”value”:”110 V AC”},{“name”:”HP @ 1 Phase – 120V”,”normalizedValue”:”1 hp”,”rank”:7,”value”:”1 hp”},{“name”:”HP @ 1 Phase – 240V”,”normalizedValue”:”3 hp”,”rank”:8,”value”:”3 hp”},{“name”:”HP @ 3 Phase – 208V”,”normalizedValue”:”3 hp”,”rank”:9,”value”:”3 hp”},{“name”:”HP @ 3 Phase – 240V”,”normalizedValue”:”5 hp”,”rank”:10,”value”:”5 hp”},{“name”:”HP @ 3 Phase – 480V”,”normalizedValue”:”10 hp”,”rank”:11,”value”:”10 hp”},{“name”:”HP @ 3 Phase – 575V”,”normalizedValue”:”15 hp”,”rank”:12,”value”:”15 hp”},{“name”:”Aux. Contact Configuration”,”normalizedValue”:”1NO, 1NC”,”rank”:13,”value”:”1NO/1NC”},{“name”:”Hz”,”normalizedValue”:”50″,”rank”:15,”value”:”50″},{“name”:”Standards”,”normalizedValue”:”REACH Art 33, WEEE (2012/19/EU)”,”value”:”REACH Art 33, WEEE (2012/19/EU)”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Depth”,”normalizedValue”:”97 mm”,”value”:”97 mm”},{“name”:”Height”,”normalizedValue”:”85 mm”,”value”:”85 mm”},{“name”:”Frame / Series / Class / Code”,”normalizedValue”:”S0″,”value”:”S0″},{“name”:”Watts Loss”,”normalizedValue”:”0.6W (Current Dependent); 7.6W (Current Independent)”,”value”:”0.6W (Current Dependent); 7.6W (Current Independent)”},{“name”:”Electrical Connection”,”normalizedValue”:”Screws”,”value”:”Screws”},{“name”:”Max. Operating Watts”,”normalizedValue”:”8 kW (at 400V, AC-3), 23 kW (at 400V, AC-1)”,”value”:”8 kW (at 400V, AC-3), 23 kW (at 400V, AC-1)”},{“name”:”Series”,”normalizedValue”:”SIRIUS 3RT20″,”value”:”SIRIUS 3RT20″},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”NEMA Size”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Horsepower @ Single Phase – 240V AC”,”normalizedValue”:”3 HP”,”value”:”3 hp”},{“name”:”Full Load Current – Inductive”,”normalizedValue”:”17 A”,”value”:”17 A”},{“name”:”Reversing Capability”,”normalizedValue”:”Non-Reversing”,”value”:”Non-Reversing”},{“name”:”Mounting Hole Diameter”,”normalizedValue”:”0.19 in”,”value”:”0.19 in”},{“name”:”Horsepower @ Three Phase – 208V AC”,”normalizedValue”:”3 HP”,”value”:”3 hp”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”10,000,000″,”value”:”10,000,000″},{“name”:”Auxiliary Contact Form”,”normalizedValue”:”1NO, 1NC”,”value”:”1NO/1NC”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail, Surface”,”value”:”DIN Rail, Surface”},{“name”:”Coil Voltage”,”normalizedValue”:”110 V AC”,”value”:”110 V AC”},{“name”:”Horsepower @ Three Phase – 480V AC”,”normalizedValue”:”10 HP”,”value”:”10 hp”},{“name”:”Number of Auxillary Contacts”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Mounting Postion”,”normalizedValue”:”Vertical”,”value”:”Vertical”},{“name”:”Frame Size”,”normalizedValue”:”S0″,”value”:”S0″},{“name”:”Overall Width”,”normalizedValue”:”2.13 in”,”value”:”2.13 in”},{“name”:”Horsepower @ Three Phase – 240V AC”,”normalizedValue”:”5 HP”,”value”:”5 hp”},{“name”:”Number of Normally Open Main Contacts”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Terminals”,”value”:”Screw Terminals”},{“name”:”Overall Depth”,”normalizedValue”:”3.63 in”,”value”:”3.63 in”},{“name”:”Response Time”,”normalizedValue”:”10 to 18 msec (AC Operation Closing Delay Operation Opening Delay Operating Times for 1.0 x Us1), 15 to 17.5 msec (DC Operation Opening Delay Operating Times For 0.8 … 1.1 X Us1), 16 to 17 msec (DC Operation Opening Delay Operating Times for 1.0 x Us), 4 to 16 msec (AC Operation Opening Delay Operating Times for 0.8 … 1.1 X Us1), 4 to 16 msec (AC Operation Opening Delay Operating Times for 1.0 x Us), 50 to 170 msec (DC Operation Closing Delay Operating Times for 0.8 … 1.1 X Us1), 55 to 80 msec (DC Operation Closing Delay Operating Times for 1.0 x Us), 9 to 38 msec (AC Operation Closing Delay)”,”value”:”10 to 18 msec (AC Operation Closing Delay Operation Opening Delay Operating Times for 1.0 x Us1), 15 to 17.5 msec (DC Operation Opening Delay Operating Times For 0.8 … 1.1 X Us1), 16 to 17 msec (DC Operation Opening Delay Operating Times for 1.0 x Us), 4 to 16 msec (AC Operation Opening Delay Operating Times for 0.8 … 1.1 X Us1), 4 to 16 msec (AC Operation Opening Delay Operating Times for 1.0 x Us), 50 to 170 msec (DC Operation Closing Delay Operating Times for 0.8 … 1.1 X Us1), 55 to 80 msec (DC Operation Closing Delay Operating Times for 1.0 x Us), 9 to 38 msec (AC Operation Closing Delay)”},{“name”:”Overall Height”,”normalizedValue”:”4.18 in”,”value”:”4.18 in”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Horsepower @ Single Phase – 120V AC”,”normalizedValue”:”1 HP”,”value”:”1 hp”},{“name”:”Frequency”,”normalizedValue”:”50 Hz”,”value”:”50 Hz”},{“name”:”Includes Auxiliary Contacts”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Embedded Surge Suppressor”,”normalizedValue”:”No”,”value”:”No”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”No Enclosure”,”value”:”No Enclosure”},{“name”:”Horsepower @ Three Phase – 600V AC”,”normalizedValue”:”15 HP”,”value”:”15 hp”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”Mounting Hole Distance – Height”,”normalizedValue”:”2.36 in”,”value”:”2.36 in”},{“name”:”Full Load Current – Resistive”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Contactor Style”,”normalizedValue”:”IEC”,”value”:”IEC”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690 V AC”,”value”:”690V AC”},{“name”:”Mounting Hole Distance – Width”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Germany”,”value”:”Germany”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.