Description
[{“name”:”Item”,”normalizedValue”:”IEC Magnetic Contactor”,”rank”:1,”value”:”IEC Magnetic Contactor”},{“name”:”Full Load Amps-Inductive”,”normalizedValue”:”25 A”,”rank”:1,”value”:”25 A”},{“name”:”Number of Poles”,”normalizedValue”:”4″,”rank”:3,”value”:”4″},{“name”:”Coil Volts”,”normalizedValue”:”240 V AC”,”rank”:4,”value”:”240 V AC”},{“name”:”Height”,”normalizedValue”:”85 mm”,”rank”:7,”value”:”85 mm”},{“name”:”Width”,”normalizedValue”:”45 mm”,”rank”:8,”value”:”45 mm”},{“name”:”Depth”,”normalizedValue”:”92 mm”,”rank”:9,”value”:”92 mm”},{“name”:”Aux. Contact Configuration”,”normalizedValue”:”1NO, 1NC”,”rank”:13,”value”:”1NO/1NC”},{“name”:”Series”,”normalizedValue”:”LC1D”,”value”:”LC1D”},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, GL, DNV, GOST, CSA, RINA, LROS, BV, CCC, UL, THIEC 60068-2-30″,”value”:”CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, GL, DNV, GOST, CSA, RINA, LROS, BV, CCC, UL, THIEC 60068-2-30″},{“name”:”Working Height”,”normalizedValue”:”Up to 9,842.52 ft”,”value”:”Up to 9842.52 ft”},{“name”:”Fuse Amps”,”normalizedValue”:”10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)”,”value”:”10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)”},{“name”:”Switching Voltage”,”normalizedValue”:”17 V (Signalling Circuit)”,”value”:”17 V (Signalling Circuit)”},{“name”:”Operating Time”,”normalizedValue”:”4 to 19 ms (Opening), 12 to 22 ms (Closing)”,”value”:”4 to 19 ms (Opening), 12 to 22 ms (Closing)”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”250 A @ 440V”,”value”:”250 A @ 440V”},{“name”:”Application”,”normalizedValue”:”Resistive Load”,”value”:”Resistive Load”},{“name”:”Includes Protective Cover”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 msec”,”value”:”1.5 ms”},{“name”:”Watts Loss”,”normalizedValue”:”2 to 3W”,”value”:”2 to 3W”},{“name”:”Mechanical Durability”,”normalizedValue”:”15 Mcycles”,”value”:”15 Mcycles”},{“name”:”Signalling Circuit Frequency”,”normalizedValue”:”25 to 400 Hz”,”value”:”25 to 400 Hz”},{“name”:”Impulse Withstand Voltage”,”normalizedValue”:”6 kV”,”value”:”6 kV”},{“name”:”Rated Short-Time Withstand Current”,”normalizedValue”:”30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”,”value”:”30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”},{“name”:”Overvoltage Category”,”normalizedValue”:”CAT III”,”value”:”CAT III”},{“name”:”Max. Temperature”,”normalizedValue”:”850°C”,”value”:”850°C”},{“name”:”Operating Speed”,”normalizedValue”:”3600 cycles per hr”,”value”:”3600 cycles per hr”},{“name”:”Switching Current”,”normalizedValue”:”5 mA (Signalling Circuit)”,”value”:”5 mA (Signalling Circuit)”},{“name”:”Thermal Amperage”,”normalizedValue”:”10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)”,”value”:”10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)”},{“name”:”Net Weight”,”normalizedValue”:”0.365 kg”,”value”:”0.365 kg”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Inrush VA”,”normalizedValue”:”70 VA”,”value”:”70 VA”},{“name”:”Insulation Resistance Range”,”normalizedValue”:”Greater Than 10 MOhms (Signalling Circuit)”,”value”:”Greater Than 10 MOhms (Signalling Circuit)”},{“name”:”Fire Rating”,”normalizedValue”:”UL 94 V1″,”value”:”UL 94 V1″},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)”,”value”:”Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)”},{“name”:”Environmental Attributes”,”normalizedValue”:”Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3″,”value”:”Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3″},{“name”:”Shock Resistance”,”normalizedValue”:”10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)”,”value”:”10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)”},{“name”:”Impedance”,”normalizedValue”:”2.5 mOhm”,”value”:”2.5 mOhm”},{“name”:”Vibration Resistance”,”normalizedValue”:”4 G (Contactor Closed), 2 G (Contactor Open)”,”value”:”4 G (Contactor Closed), 2 G (Contactor Open)”},{“name”:”Hold VA”,”normalizedValue”:”7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)”,”value”:”7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Rated Insulation Volts”,”normalizedValue”:”600/690V”,”value”:”600/690V”},{“name”:”Rated Making Capacity”,”normalizedValue”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 250 A @ 440V (Power Circuit)”,”value”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 250 A @ 440V (Power Circuit)”},{“name”:”Tightening Torque”,”normalizedValue”:”1.7 Nm”,”value”:”1.7 Nm”},{“name”:”Mounts On”,”normalizedValue”:”Plate, Rail”,”value”:”Plate, Rail”},{“name”:”Features”,”normalizedValue”:”Without Built-In Suppressor Module”,”value”:”Without Built-In Suppressor Module”},{“name”:”Rated Voltage”,”normalizedValue”:”690V AC, 300V DC”,”value”:”690V AC, 300V DC”},{“name”:”Electrical Durability”,”normalizedValue”:”0.8 Mcycles (25 A, AC-1, Less than 440 V)”,”value”:”0.8 Mcycles (25 A, AC-1, Less than 440 V)”},{“name”:”Safety Reliability Level”,”normalizedValue”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″,”value”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC”,”value”:”Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC”},{“name”:”Product Certifications”,”normalizedValue”:”GL, DNV, GOST, CSA, RINA, LROS (Lloyds register of shipping), BV, CCC, UL”,”value”:”GL, DNV, GOST, CSA, RINA, LROS (Lloyds register of shipping), BV, CCC, UL”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V for signalling circuit”,”value”:”17 V for signalling circuit”},{“name”:”Auxiliary Contacts Type”,”normalizedValue”:”Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1″,”value”:”Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1″},{“name”:”Pollution Degree”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Rated Short Time Withstand Current”,”normalizedValue”:”30 A 104°F (40°C) – 10 min for power circuit, 61 A 104°F (40°C) – 1 min for power circuit, 105 A 104°F (40°C) – 10 s for power circuit, 210 A 104°F (40°C) – 1 s for power circuit, 100 A – 1 s for signalling circuit, 120 A – 500 ms for signalling circuit, 140 A – 100 ms for signalling circuit”,”value”:”30 A 104°F (40°C) – 10 min for power circuit, 61 A 104°F (40°C) – 1 min for power circuit, 105 A 104°F (40°C) – 10 s for power circuit, 210 A 104°F (40°C) – 1 s for power circuit, 100 A – 1 s for signalling circuit, 120 A – 500 ms for signalling circuit, 140 A – 100 ms for signalling circuit”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-3, AC-1, AC-3e, AC-4″,”value”:”AC-1, AC-3, AC-3e, AC-4″},{“name”:”Mounting Support”,”normalizedValue”:”Rail, Plate”,”value”:”Plate, Rail”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947″,”value”:”6 kV IEC 60947″},{“name”:”Mechanical Robustness”,”normalizedValue”:”Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms)”,”value”:”Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms)”},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat”,”value”:”IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat”},{“name”:”Power Dissipation Per Pole”,”normalizedValue”:”1.56 W AC to 1″,”value”:”1.56 W AC-1″},{“name”:”Protective Cover”,”normalizedValue”:”With”,”value”:”With”},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A at 440 V for power circuit conforming to IEC 60947″,”value”:”140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A at 440 V for power circuit conforming to IEC 60947″},{“name”:”Poles Description”,”normalizedValue”:”4P”,”value”:”4P”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 25 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”,”value”:”10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 25 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 140°F (60°C)) for signalling circuit, 25 A (at 140°F (60°C)) for power circuit”,”value”:”10 A (at 140°F (60°C)) for signalling circuit, 25 A (at 140°F (60°C)) for power circuit”},{“name”:”Fire Resistance”,”normalizedValue”:”1562°F IEC 60695-2-1″,”value”:”1562°F (850°C) IEC 60695-2-1″},{“name”:”Hold-In Power Consumption in VA”,”normalizedValue”:”7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))”,”value”:”7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”240 V AC 50/60 Hz”,”value”:”240 V AC 50/60 Hz”},{“name”:”Protective Treatment”,”normalizedValue”:”THIEC 60068-2-30″,”value”:”THIEC 60068-2-30″},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1″,”value”:”Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1″},{“name”:”Contact Compatibility”,”normalizedValue”:”M6″,”value”:”M6″},{“name”:”Average Impedance”,”normalizedValue”:”2.5 mOhm – Ith 25 A 50 Hz for power circuit”,”value”:”2.5 mOhm – Ith 25 A 50 Hz for power circuit”},{“name”:”Auxiliary Contact Composition”,”normalizedValue”:”1 NO + 1 NC”,”value”:”1 NO + 1 NC”},{“name”:”Product Or Component Type”,”normalizedValue”:”Contactor”,”value”:”Contactor”},{“name”:”Operating Altitude”,”normalizedValue”:”0 to 9842.52 ft (0 to 3000 m)”,”value”:”0 to 9842.52 ft (0 to 3000 m)”},{“name”:”Permissible Ambient Air Temperature Around The Device”,”normalizedValue”:”-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating”,”value”:”-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP20 front face IEC 60529″,”value”:”IP20 front face IEC 60529″},{“name”:”Pole Contact Composition”,”normalizedValue”:”4 NO”,”value”:”4 NO”},{“name”:”Heat Dissipation”,”normalizedValue”:”2 to 3 W at 50/60 Hz”,”value”:”2 to 3 W at 50/60 Hz”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”3600 cyc/h 140°F (60°C)”,”value”:”3600 cyc/h 140°F (60°C)”},{“name”:”Rated Operational Current”,”normalizedValue”:”25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit”,”value”:”25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit”},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm for signalling circuit”,”value”:”Greater than 10 MOhm for signalling circuit”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA (for signalling circuit)”,”value”:”5 mA for signalling circuit”},{“name”:”Inrush Power in VA”,”normalizedValue”:”70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))”,”value”:”70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94″,”value”:”V1 conforming to UL 94″},{“name”:”Connections – Terminals”,”normalizedValue”:”Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) – cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) – cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end”,”value”:”Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) – cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) – cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) – cable stiffness: solid without cable end”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Multiple”,”value”:”Multiple”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.