IEC Magnetic Contactor, 3 Poles, 600 V AC, 25 A

$197,99

IEC Magnetic Contactor

9999 in stock

SKU: GRG0850048 Category:

Description

[{“name”:”Item”,”normalizedValue”:”IEC Magnetic Contactor”,”rank”:1,”value”:”IEC Magnetic Contactor”},{“name”:”Auxiliary Contact Form”,”normalizedValue”:”1NO/1NC”,”rank”:2,”value”:”1NO/1NC”},{“name”:”Coil Voltage”,”normalizedValue”:”600 V AC”,”rank”:3,”value”:”600 V AC”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:4,”value”:”3″},{“name”:”Full Load Amps-Inductive”,”normalizedValue”:”25 A”,”rank”:5,”value”:”25 A”},{“name”:”Reversing Capability”,”normalizedValue”:”Non-Reversing”,”rank”:7,”value”:”Non-Reversing”},{“name”:”Number of Auxillary Contacts”,”normalizedValue”:”2″,”rank”:9,”value”:”2″},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, CCC, UL, GL, RINA, DNV, LROS, CSA, GOST, BV, UKCA, THIEC 60068-2-30″,”rank”:10,”value”:”CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, CCC, UL, GL, RINA, DNV, LROS, CSA, GOST, BV, UKCA, THIEC 60068-2-30″},{“name”:”Coil Volts”,”normalizedValue”:”600 V AC”,”value”:”600 V AC”},{“name”:”Depth”,”normalizedValue”:”92 mm”,”value”:”92 mm”},{“name”:”Height”,”normalizedValue”:”85 mm”,”value”:”85 mm”},{“name”:”Series”,”normalizedValue”:”LC1D”,”value”:”LC1D”},{“name”:”HP @ 3 Phase – 575V”,”normalizedValue”:”20 hp”,”value”:”20 hp”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Features”,”normalizedValue”:”Without Built-In Suppressor Module”,”value”:”Without Built-In Suppressor Module”},{“name”:”Application”,”normalizedValue”:”Motor Control, Resistive Load”,”value”:”Motor Control, Resistive Load”},{“name”:”Max. Temperature”,”normalizedValue”:”850°C”,”value”:”850°C”},{“name”:”Rated Short-Time Withstand Current”,”normalizedValue”:”240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”,”value”:”240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”450 A @ 440V”,”value”:”450 A @ 440V”},{“name”:”Fire Rating”,”normalizedValue”:”UL 94 V1″,”value”:”UL 94 V1″},{“name”:”Signalling Circuit Frequency”,”normalizedValue”:”25 to 400 Hz”,”value”:”25 to 400 Hz”},{“name”:”Electrical Durability”,”normalizedValue”:”1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V)”,”value”:”1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V)”},{“name”:”Rated Voltage”,”normalizedValue”:”690V AC, 300V DC”,”value”:”690V AC, 300V DC”},{“name”:”Includes Protective Cover”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Watts Loss”,”normalizedValue”:”2 to 3W”,”value”:”2 to 3W”},{“name”:”Inrush VA”,”normalizedValue”:”70 VA”,”value”:”70 VA”},{“name”:”Working Height”,”normalizedValue”:”Up to 9,842.52 ft”,”value”:”Up to 9842.52 ft”},{“name”:”Max. Operating Watts”,”normalizedValue”:”5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)”,”value”:”5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)”},{“name”:”Operating Time”,”normalizedValue”:”12 to 22 ms (Closing), 4 to 19 ms (Opening)”,”value”:”12 to 22 ms (Closing), 4 to 19 ms (Opening)”},{“name”:”Switching Current”,”normalizedValue”:”5 mA (Signalling Circuit)”,”value”:”5 mA (Signalling Circuit)”},{“name”:”Impulse Withstand Voltage”,”normalizedValue”:”6 kV”,”value”:”6 kV”},{“name”:”Mounts On”,”normalizedValue”:”Plate, Rail”,”value”:”Plate, Rail”},{“name”:”Environmental Attributes”,”normalizedValue”:”Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3″,”value”:”Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3″},{“name”:”Switching Voltage”,”normalizedValue”:”17 V (Signalling Circuit)”,”value”:”17 V (Signalling Circuit)”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Overvoltage Category”,”normalizedValue”:”CAT III”,”value”:”CAT III”},{“name”:”Vibration Resistance”,”normalizedValue”:”4 G (Contactor Closed), 2 G (Contactor Open)”,”value”:”4 G (Contactor Closed), 2 G (Contactor Open)”},{“name”:”Shock Resistance”,”normalizedValue”:”8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)”,”value”:”8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)”},{“name”:”Operating Speed”,”normalizedValue”:”3600 cycles per hr”,”value”:”3600 cycles per hr”},{“name”:”Rated Making Capacity”,”normalizedValue”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)”,”value”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)”},{“name”:”Impedance”,”normalizedValue”:”2 mOhm”,”value”:”2 mOhm”},{“name”:”Thermal Amperage”,”normalizedValue”:”10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)”,”value”:”10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 msec”,”value”:”1.5 ms”},{“name”:”Mechanical Durability”,”normalizedValue”:”15 Mcycles”,”value”:”15 Mcycles”},{“name”:”Fuse Amps”,”normalizedValue”:”10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)”,”value”:”10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)”},{“name”:”Rated Insulation Volts”,”normalizedValue”:”600/690V”,”value”:”600/690V”},{“name”:”Net Weight”,”normalizedValue”:”0.37 kg”,”value”:”0.37 kg”},{“name”:”Tightening Torque”,”normalizedValue”:”1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)”,”value”:”1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)”},{“name”:”Insulation Resistance Range”,”normalizedValue”:”Greater Than 10 MOhms (Signalling Circuit)”,”value”:”Greater Than 10 MOhms (Signalling Circuit)”},{“name”:”Hold VA”,”normalizedValue”:”7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)”,”value”:”7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)”,”value”:”Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)”},{“name”:”Motor Power Kw”,”normalizedValue”:”5.5 kW at 220…230 V AC 50/60 Hz (AC-3), 11 kW at 380…400 V AC 50/60 Hz (AC-3), 11 kW at 415…440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660…690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220…230 V AC 50/60 Hz (AC-3e), 11 kW at 380…400 V AC 50/60 Hz (AC-3e), 11 kW at 415…440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660…690 V AC 50/60 Hz (AC-3e)”,”value”:”5.5 kW at 220…230 V AC 50/60 Hz (AC-3), 11 kW at 380…400 V AC 50/60 Hz (AC-3), 11 kW at 415…440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660…690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220…230 V AC 50/60 Hz (AC-3e), 11 kW at 380…400 V AC 50/60 Hz (AC-3e), 11 kW at 415…440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660…690 V AC 50/60 Hz (AC-3e)”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94″,”value”:”V1 conforming to UL 94″},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit","value":"10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit"},{"name":"[Icw] Rated Short-Time Withstand Current","normalizedValue":"240 A 40°C - 10 s for power circuit, 380 A 40°C - 1 s for power circuit, 50 A 40°C - 10 min for power circuit, 120 A 40°C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit","value":"240 A 40°C - 10 s for power circuit, 380 A 40°C - 1 s for power circuit, 50 A 40°C - 10 min for power circuit, 120 A 40°C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit"},{"name":"Maximum Operating Rate","normalizedValue":"3600 cyc/h 60°C","value":"3600 cyc/h 60°C"},{"name":"Minimum Switching Voltage","normalizedValue":"17 V for signalling circuit","value":"17 V for signalling circuit"},{"name":"Heat Dissipation","normalizedValue":"2-3 W at 50/60 Hz","value":"2-3 W at 50/60 Hz"},{"name":"Product or Component Type","normalizedValue":"contactor","value":"contactor"},{"name":"Control Circuit Type","normalizedValue":"AC 50/60 Hz","value":"AC 50/60 Hz"},{"name":"[Ith] Conventional Free Air Thermal Current","normalizedValue":"10 A (at 60°C) for signalling circuit, 40 A (at 60°C) for power circuit","value":"10 A (at 60°C) for signalling circuit, 40 A (at 60°C) for power circuit"},{"name":"Contactor Application","normalizedValue":"Motor control Resistive load","value":"motor control, resistive load"},{"name":"Average Impedance","normalizedValue":"2 mOhm - Ith 40 A 50 Hz for power circuit","value":"2 mOhm - Ith 40 A 50 Hz for power circuit"},{"name":"Connections - Terminals","normalizedValue":"control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end","value":"control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end"},{"name":"Protective Treatment","normalizedValue":"THIEC 60068-2-30","value":"THIEC 60068-2-30"},{"name":"Range of Product","normalizedValue":"TeSys Deca","value":"TeSys Deca"},{"name":"Fire Resistance","normalizedValue":"850°C IEC 60695-2-1","value":"850°C IEC 60695-2-1"},{"name":"[Uc] Control Circuit Voltage","normalizedValue":"600 V AC 50/60 Hz","value":"600 V AC 50/60 Hz"},{"name":"Power Dissipation Per Pole","normalizedValue":"3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e","value":"3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e"},{"name":"[Ue] Rated Operational Voltage","normalizedValue":"power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC","value":"power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC"},{"name":"Hold-In Power Consumption In Va","normalizedValue":"7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C), 7-7 VA 50 Hz cos phi 0.3 (at 20°C)","value":"7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C), 7-7 VA 50 Hz cos phi 0.3 (at 20°C)"},{"name":"Protective Cover","normalizedValue":"With","value":"with"},{"name":"Operating Altitude","normalizedValue":"0...9842.52 ft (0...3000 m)","value":"0...9842.52 ft (0...3000 m)"},{"name":"Auxiliary Contacts Type","normalizedValue":"mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1","value":"mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1"},{"name":"Mounting Support","normalizedValue":"Rail, Plate","value":"plate, rail"},{"name":"Mechanical Robustness","normalizedValue":"vibrations contactor open 2 Gn, 5...300 Hz) , vibrations contactor closed 4 Gn, 5...300 Hz) , shocks contactor closed 15 Gn for 11 ms) , shocks contactor open 8 Gn for 11 ms)","value":"vibrations contactor open 2 Gn, 5...300 Hz) , vibrations contactor closed 4 Gn, 5...300 Hz) , shocks contactor closed 15 Gn for 11 ms) , shocks contactor open 8 Gn for 11 ms)"},{"name":"Irms Rated Making Capacity","normalizedValue":"140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947","value":"140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947"},{"name":"Permissible Ambient Air Temperature Around The Device","normalizedValue":"-40-60°C, 60-70°C with derating","value":"-40-60°C, 60-70°C with derating"},{"name":"Poles Description","normalizedValue":"3P","value":"3P"},{"name":"Inrush Power In Va","normalizedValue":"70-70 VA 60 Hz cos phi 0.75 (at 20°C), 70-70 VA 50 Hz cos phi 0.75 (at 20°C)","value":"70-70 VA 60 Hz cos phi 0.75 (at 20°C), 70-70 VA 50 Hz cos phi 0.75 (at 20°C)"},{"name":"[Ie] Rated Operational Current","normalizedValue":"25 A (at <60°C) at <= 440 V AC AC-3 for power circuit, 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60°C) at <= 440 V AC AC-3e for power circuit","value":"25 A (at <60°C) at <= 440 V AC AC-3 for power circuit, 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60°C) at <= 440 V AC AC-3e for power circuit"},{"name":"Ip Degree of Protection","normalizedValue":"IP20 front face IEC 60529","value":"IP20 front face IEC 60529"},{"name":"Insulation Resistance","normalizedValue":"> 10 MOhm for signalling circuit”,”value”:”> 10 MOhm for signalling circuit”},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL”,”value”:”power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-4, AC-3, AC-1, AC-3e”,”value”:”AC-4, AC-3, AC-1, AC-3e”},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat”,”value”:”IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat”},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors”,”value”:”3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947″,”value”:”6 kV IEC 60947″},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA (for signalling circuit)”,”value”:”5 mA for signalling circuit”},{“name”:”Horsepower @ Single Phase – 240V AC”,”normalizedValue”:”3 HP”,”value”:”3 hp”},{“name”:”Full Load Current – Resistive”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Horsepower @ Three Phase – 240V AC”,”normalizedValue”:”7.5 HP”,”value”:”7 1/2 hp”},{“name”:”Horsepower @ Three Phase – 480V AC”,”normalizedValue”:”15 HP”,”value”:”15 hp”},{“name”:”Horsepower @ Three Phase – 208V AC”,”normalizedValue”:”7.5 HP”,”value”:”7 1/2 hp”},{“name”:”Full Load Current – Inductive”,”normalizedValue”:”25 A”,”value”:”25 A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “IEC Magnetic Contactor, 3 Poles, 600 V AC, 25 A”