IEC Control Relay, 4NO, 240VAC, 10A

$49,49

IEC Control Relay, Current Rating 10 A, Contact Form 4NO, Contact Rating (DC) 2 A @ 125/250/600V, Coil Voltage 240V AC, Contact Rating (AC) 10 A @ 120/240/480/600V, Relay Style IEC, Electrical Connection Screw Clamp, Mounting Style DIN Rail and Surface, Power Consumption 4.5 VA, IP Rating IP2X, Compatible with Series TeSys SK Mini Control Relays, Maximum Operating Temperature 122 Degrees F, Frequency 50/60 Hz, Body Depth 2.24 in, Body Height 2.28 in, Body Width 1.77 in

Out of stock

SKU: GRG3198587 Category:

Description

[{“name”:”Item – Relay”,”normalizedValue”:”IEC Style Control Relay”,”rank”:1,”value”:”IEC Style Control Relay”},{“name”:”Coil Volts”,”normalizedValue”:”240 V AC”,”rank”:2,”value”:”240V AC”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”10A @ 120/240/480/600V”,”rank”:3,”value”:”10A @ 120/240/480/600V”},{“name”:”DC Contact Rating – Relay”,”normalizedValue”:”2.00A @ 125/250/600V”,”rank”:4,”value”:”2.00A @ 125/250/600V”},{“name”:”Number of Pins – Relay”,”normalizedValue”:”10″,”rank”:5,”value”:”10″},{“name”:”Contact Form – Relay”,”normalizedValue”:”SPST-NO”,”rank”:6,”value”:”(4) SPST-NO”},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail, Surface”,”rank”:7,”value”:”DIN Rail, Surface”},{“name”:”Hz – Electrical”,”normalizedValue”:”50, 60″,”value”:”50 Hz, 60 Hz”},{“name”:”Mounting”,”normalizedValue”:”Din Rail/Panel”,”value”:”Din Rail/Panel”},{“name”:”Contact Form”,”normalizedValue”:”4NO”,”value”:”4NO”},{“name”:”Overall Height – Relay”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Hz”,”normalizedValue”:”50/60″,”value”:”50/60″},{“name”:”Standards”,”normalizedValue”:”CCC, CSA Certified, EAC, IEC, REACH, RoHS Compliant, UL Listed”,”value”:”CCC, CSA Certified, EAC, IEC, REACH, RoHS Compliant, UL Listed”},{“name”:”Contact Amp Rating (Resistive)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Body Depth – Relay”,”normalizedValue”:”2.24 in”,”value”:”2.24 in”},{“name”:”Contact Material”,”normalizedValue”:”Silver Nickel”,”value”:”Silver Nickel”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.77 in”,”value”:”1.77 in”},{“name”:”Response Time”,”normalizedValue”:”10 to 20 msec (Coil De-Energisation and NO Opening), 10 to 20 msec (Coil Energisation and NO Closing)”,”value”:”10 to 20 msec (Coil De-Energisation and NO Opening), 10 to 20 msec (Coil Energisation and NO Closing)”},{“name”:”Power Consumption – Relay”,”normalizedValue”:”4.5 VA”,”value”:”4.5 VA”},{“name”:”Item”,”normalizedValue”:”IEC Control Relay”,”value”:”IEC Control Relay”},{“name”:”Body Height – Relay”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Coil Rating”,”normalizedValue”:”30VA Inrush, 4.5VA Sealed”,”value”:”30VA Inrush, 4.5VA Sealed”},{“name”:”Operating Time”,”normalizedValue”:”10…20 ms coil de-energisation and NO opening || 10…20 ms coil energisation and NO closing”,”value”:”10…20 ms coil de-energisation and NO opening || 10…20 ms coil energisation and NO closing”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”2 msec”,”value”:”2 ms”},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Non Overlap Distance”,”normalizedValue”:”0.5 mm”,”value”:”0.5 mm”},{“name”:”Tightening Torque”,”normalizedValue”:”1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2″,”value”:”1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2″},{“name”:”Mounting Support”,”normalizedValue”:”rail || plate”,”value”:”rail || plate”},{“name”:”Hold-In Power Consumption In Va”,”normalizedValue”:”4.5-4.5 VA 20°C)”,”value”:”4.5-4.5 VA 20°C)”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”230…240 V AC 50/60 Hz”,”value”:”230…240 V AC 50/60 Hz”},{“name”:”Utilisation Category”,”normalizedValue”:”DC-13 || AC-15″,”value”:”DC-13 || AC-15″},{“name”:”Device Short Name”,”normalizedValue”:”CA2K”,”value”:”CA2K”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end”,”value”:”screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end”},{“name”:”Inrush Power In Va”,”normalizedValue”:”30-30 VA 20°C)”,”value”:”30-30 VA 20°C)”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”drop-out 0.2…0.75 Uc 50°C) || operational 0.8…1.15 Uc 50°C)”,”value”:”drop-out 0.2…0.75 Uc 50°C) || operational 0.8…1.15 Uc 50°C)”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Product Certifications”,”normalizedValue”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”,”value”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14″,”value”:”690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14″},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG IEC 60947 || 10 A gG VDE 0660″,”value”:”10 A gG IEC 60947 || 10 A gG VDE 0660″},{“name”:”Maximum Operating Rate”,”normalizedValue”:”10000 cyc/h”,”value”:”10000 cyc/h”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 10 MOhm”,”value”:”\u003e 10 MOhm”},{“name”:”Irms Rated Making Capacity”,”normalizedValue”:”110 A IEC 60947″,”value”:”110 A IEC 60947″},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m) without derating”,”value”:”6561.68 ft (2000 m) without derating”},{“name”:”Contactor Application”,”normalizedValue”:”control circuit”,”value”:”control circuit”},{“name”:”Heat Dissipation”,”normalizedValue”:”1.3 to 1.3 W”,”value”:”1.3-1.3 W”},{“name”:”Mechanical Durability”,”normalizedValue”:”10 Mcycles”,”value”:”10 Mcycles”},{“name”:”Protective Treatment”,”normalizedValue”:”TC IEC 60068″,”value”:”TC IEC 60068″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP2X”,”value”:”IP2X”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-50-80°C”,”value”:”-50-80°C”},{“name”:”Depth”,”normalizedValue”:”57 mm”,”value”:”57 mm”},{“name”:”Pole Contact Composition”,”normalizedValue”:”4 NO”,”value”:”4 NO”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-50°C”,”value”:”-25-50°C”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Product Name”,”normalizedValue”:”TeSys CAK”,”value”:”TeSys CAK”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”10 A 50°C”,”value”:”10 A 50°C”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”\u003c= 690 V \u003c= 400 Hz”,”value”:”\u003c= 690 V \u003c= 400 Hz”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102″,”value”:”V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102″},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Height”,”normalizedValue”:”58 mm”,”value”:”58 mm”},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations contactor open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″,”value”:”vibrations contactor open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″},{“name”:”Number of Pins”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp”,”value”:”Screw Clamp”},{“name”:”Compatible with Series”,”normalizedValue”:”Mini Control Relays”,”value”:”TeSys SK Mini Control Relays”},{“name”:”Weight”,”normalizedValue”:”0.4 lb”,”value”:”0.4 lb”},{“name”:”Power Consumption”,”normalizedValue”:”4.5 VA”,”value”:”4.5 VA”},{“name”:”Body Height”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Body Depth”,”normalizedValue”:”2.24 in”,”value”:”2.24 in”},{“name”:”Current Rating”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”10 A @ 120/240/480/600V”,”value”:”10 A @ 120/240/480/600V”},{“name”:”Input Voltage”,”normalizedValue”:”230-240V AC”,”value”:”230-240V AC”},{“name”:”IP Rating”,”normalizedValue”:”IP2X”,”value”:”IP2X”},{“name”:”Contact Rating (DC)”,”normalizedValue”:”2 A @ 125/250/600V”,”value”:”2 A @ 125/250/600V”},{“name”:”Relay Style”,”normalizedValue”:”IEC”,”value”:”IEC”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail and Surface”,”value”:”DIN Rail and Surface”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Body Width”,”normalizedValue”:”1.77 in”,”value”:”1.77 in”},{“name”:”Overall Height”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Coil Voltage”,”normalizedValue”:”240 V AC”,”value”:”240V AC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “IEC Control Relay, 4NO, 240VAC, 10A”