IEC Control Relay, 1NO/1NC, 480VAC, 10A

$65,49

IEC Control Relay, Current Rating 10 A, Contact Form 1NO/1NC, Contact Rating (DC) 2 A @ 125/250/600V, Coil Voltage 480V AC, Contact Rating (AC) 10 A @ 120/240/480/600V, Relay Style IEC, Electrical Connection Screw Clamp, Mounting Style DIN Rail, Power Consumption 4.5 VA, IP Rating IP2X, Compatible with Series TeSys SK Mini Control Relays, Maximum Operating Temperature 122 Degrees F, Frequency 50/60 Hz, Body Depth 2.19 in, Body Height 2.2 in, Body Width 1.06 in, Contact Material Silver Nickel

9999 in stock

SKU: GRG0518935 Category:

Description

[{“name”:”Item – Relay”,”normalizedValue”:”IEC Style Control Relay”,”rank”:1,”value”:”IEC Style Control Relay”},{“name”:”Coil Volts”,”normalizedValue”:”480 V AC”,”rank”:2,”value”:”480V AC”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”10A @ 120/240/480/600V”,”rank”:3,”value”:”10A @ 120/240/480/600V”},{“name”:”DC Contact Rating – Relay”,”normalizedValue”:”2.00A @ 125/250/600V”,”rank”:4,”value”:”2.00A @ 125/250/600V”},{“name”:”Number of Pins – Relay”,”normalizedValue”:”6″,”rank”:5,”value”:”6″},{“name”:”Contact Form – Relay”,”normalizedValue”:”SPST-NO, SPST-NC”,”rank”:6,”value”:”(1) SPST-NC, (1) SPST-NO”},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail, Surface”,”rank”:7,”value”:”DIN Rail, Surface”},{“name”:”Body Height – Relay”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Body Depth – Relay”,”normalizedValue”:”2.24 in”,”value”:”2.24 in”},{“name”:”Contact Material”,”normalizedValue”:”Silver Nickel”,”value”:”Silver Nickel”},{“name”:”Power Consumption – Relay”,”normalizedValue”:”4.5 VA”,”value”:”4.5 VA”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.77 in”,”value”:”1.77 in”},{“name”:”Item”,”normalizedValue”:”IEC Control Relay”,”value”:”IEC Control Relay”},{“name”:”Contact Form”,”normalizedValue”:”1NO/1NC”,”value”:”1NO/1NC”},{“name”:”Hz – Electrical”,”normalizedValue”:”50, 60″,”value”:”50 Hz, 60 Hz”},{“name”:”Response Time”,”normalizedValue”:”6 to 8 msec (Coil De-Energisation and NO Opening), 7 to 14 msec (Coil Energisation and NO Closing), 8 to 10 msec (Coil De-Energisation and NC Closing), 8 to 16 msec (Coil Energisation and NC Opening)”,”value”:”6 to 8 msec (Coil De-Energisation and NO Opening), 7 to 14 msec (Coil Energisation and NO Closing), 8 to 10 msec (Coil De-Energisation and NC Closing), 8 to 16 msec (Coil Energisation and NC Opening)”},{“name”:”Overall Height – Relay”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Contact Amp Rating (Resistive)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Coil Rating”,”normalizedValue”:”30VA Inrush, 4.5VA Sealed”,”value”:”30VA Inrush, 4.5VA Sealed”},{“name”:”Hz”,”normalizedValue”:”50/60″,”value”:”50/60″},{“name”:”Mounting”,”normalizedValue”:”Din Rail/Panel”,”value”:”Din Rail/Panel”},{“name”:”Standards”,”normalizedValue”:”BS, cULus Listed, IEC, NF C, RoHS Compliant, VDE Approved”,”value”:”BS, cULus Listed, IEC, NF C, RoHS Compliant, VDE Approved”},{“name”:”Width”,”normalizedValue”:”27 mm”,”value”:”27 mm”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”480 V AC 50/60 Hz”,”value”:”480 V AC 50/60 Hz”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP2X”,”value”:”IP2X”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”\u003c= 690 V \u003c= 400 Hz”,”value”:”\u003c= 690 V \u003c= 400 Hz”},{“name”:”Pole Contact Composition”,”normalizedValue”:”1 NO + 1 NC”,”value”:”1 NO + 1 NC”},{“name”:”Heat Dissipation”,”normalizedValue”:”1.4 to 1.4 W”,”value”:”1.4-1.4 W”},{“name”:”Mechanical Durability”,”normalizedValue”:”10 Mcycles”,”value”:”10 Mcycles”},{“name”:”Operating Time”,”normalizedValue”:”6…8 ms coil de-energisation and NO opening || 7…14 ms coil energisation and NO closing || 8…10 ms coil de-energisation and NC closing || 8…16 ms coil energisation and NC opening”,”value”:”6…8 ms coil de-energisation and NO opening || 7…14 ms coil energisation and NO closing || 8…10 ms coil de-energisation and NC closing || 8…16 ms coil energisation and NC opening”},{“name”:”Product Name”,”normalizedValue”:”TeSys CASK”,”value”:”TeSys CASK”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gL VDE 0660 || 10 A gL IEC 60947″,”value”:”10 A gL VDE 0660 || 10 A gL IEC 60947″},{“name”:”Product Certifications”,”normalizedValue”:”CB Scheme || cULus || EAC || CE || UKCA”,”value”:”CB Scheme || cULus || EAC || CE || UKCA”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947 || 690 V VDE 0110 group C || 690 V BS 5424 || 690 V UL 508 || 690 V CSA C22.2 No 14″,”value”:”690 V IEC 60947 || 690 V VDE 0110 group C || 690 V BS 5424 || 690 V UL 508 || 690 V CSA C22.2 No 14″},{“name”:”Inrush Power In Va”,”normalizedValue”:”16-16 VA 20°C)”,”value”:”16-16 VA 20°C)”},{“name”:”Hold-In Power Consumption In Va”,”normalizedValue”:”4.2-4.2 VA 20°C)”,”value”:”4.2-4.2 VA 20°C)”},{“name”:”Mounting Support”,”normalizedValue”:”rail || plate”,”value”:”rail || plate”},{“name”:”Device Short Name”,”normalizedValue”:”CA2SK”,”value”:”CA2SK”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”10 A 55°C”,”value”:”10 A 55°C”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”1200 cyc/h”,”value”:”1200 cyc/h”},{“name”:”Contactor Application”,”normalizedValue”:”control circuit”,”value”:”control circuit”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Tightening Torque”,”normalizedValue”:”0.8 N.m screw clamp terminals pozidriv No 1″,”value”:”0.8 N.m screw clamp terminals pozidriv No 1″},{“name”:”Utilisation Category”,”normalizedValue”:”AC-15 || DC-13″,”value”:”AC-15 || DC-13″},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”drop-out 0.2…0.75 Uc 50°C) || operational 0.85…1.1 Uc 50°C)”,”value”:”drop-out 0.2…0.75 Uc 50°C) || operational 0.85…1.1 Uc 50°C)”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m) without derating”,”value”:”6561.68 ft (2000 m) without derating”},{“name”:”Height”,”normalizedValue”:”56 mm”,”value”:”56 mm”},{“name”:”Depth”,”normalizedValue”:”55.5 mm”,”value”:”55.5 mm”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 1.5-6 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.5-6 mm²flexible without cable end || screw clamp terminals 1 0.35-6 mm²flexible with cable end || screw clamp terminals 2 0.35-1.5 mm²flexible with cable end || screw clamp terminals 2 0.35-2.5 mm²flexible without cable end”,”value”:”screw clamp terminals 1 1.5-6 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.5-6 mm²flexible without cable end || screw clamp terminals 1 0.35-6 mm²flexible with cable end || screw clamp terminals 2 0.35-1.5 mm²flexible with cable end || screw clamp terminals 2 0.35-2.5 mm²flexible without cable end”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-50-70°C”,”value”:”-50-70°C”},{“name”:”Protective Treatment”,”normalizedValue”:”TC IEC 60068″,”value”:”TC IEC 60068″},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Coil Voltage”,”normalizedValue”:”480 V AC”,”value”:”480V AC”},{“name”:”Contact Rating (DC)”,”normalizedValue”:”2 A @ 125/250/600V”,”value”:”2 A @ 125/250/600V”},{“name”:”Body Width”,”normalizedValue”:”1.06 in”,”value”:”1.06 in”},{“name”:”Relay Style”,”normalizedValue”:”IEC”,”value”:”IEC”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp”,”value”:”Screw Clamp”},{“name”:”Current Rating”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Input Voltage”,”normalizedValue”:”480V AC”,”value”:”480V AC”},{“name”:”Body Depth”,”normalizedValue”:”2.19 in”,”value”:”2.19 in”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”10 A @ 120/240/480/600V”,”value”:”10 A @ 120/240/480/600V”},{“name”:”Overall Height”,”normalizedValue”:”2.2 in”,”value”:”2.2 in”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”IP Rating”,”normalizedValue”:”IP2X”,”value”:”IP2X”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”Power Consumption”,”normalizedValue”:”4.5 VA”,”value”:”4.5 VA”},{“name”:”Body Height”,”normalizedValue”:”2.2 in”,”value”:”2.2 in”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Number of Pins”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Weight”,”normalizedValue”:”0.29 lb”,”value”:”0.29 lb”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Compatible with Series”,”normalizedValue”:”Mini Control Relays”,”value”:”TeSys SK Mini Control Relays”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Less than or Equal to 690 V Less than or Equal to 400 Hz”,”value”:”Less than or Equal to 690 V Less than or Equal to 400 Hz”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 131°F (55°C))”,”value”:”10 A (at 131°F (55°C))”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947; 690 V VDE 0110 group C; 690 V BS 5424; 690 V UL 508; 690 V CSA C22.2 No 14″,”value”:”690 V IEC 60947; 690 V VDE 0110 group C; 690 V BS 5424; 690 V UL 508; 690 V CSA C22.2 No 14″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Czechia”,”value”:”Czechia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “IEC Control Relay, 1NO/1NC, 480VAC, 10A”