Description
[{“name”:”Item”,”normalizedValue”:”Auxiliary Contact Block”,”rank”:1,”value”:”Auxiliary Contact Block”},{“name”:”Number of NO Aux. Contacts”,”normalizedValue”:”2″,”rank”:3,”value”:”2″},{“name”:”Number of NC Aux. Contacts”,”normalizedValue”:”0″,”rank”:4,”value”:”0″},{“name”:”Amps”,”normalizedValue”:”10 A”,”rank”:5,”value”:”10 A”},{“name”:”Mounting”,”normalizedValue”:”Front”,”rank”:7,”value”:”Front”},{“name”:”For Use With”,”normalizedValue”:”LC1K06; LC1K09; LC1K12; LP1K06; LP1K09; LP1K12 Magnetic Contactors”,”rank”:8,”value”:”LC1K06; LC1K09; LC1K12; LP1K06; LP1K09; LP1K12 Magnetic Contactors”},{“name”:”Number of Contacts”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Code”,”normalizedValue”:”X to Z”,”value”:”X to Z”},{“name”:”Voltage”,”normalizedValue”:”690V AC”,”value”:”690V AC”},{“name”:”Width”,”normalizedValue”:”38 mm”,”value”:”38 mm”},{“name”:”Height”,”normalizedValue”:”30 mm”,”value”:”30 mm”},{“name”:”Features”,”normalizedValue”:”Mercury Free, Toxic Heavy Metal Free”,”value”:”Mercury Free, Toxic Heavy Metal Free”},{“name”:”Depth”,”normalizedValue”:”35 mm”,”value”:”35 mm”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, JIS C8201-5-1, CB, CCC, CE, UKCA”,”value”:”EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, JIS C8201-5-1, CB, CCC, CE, UKCA”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Number of Normally Open Contacts”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Number of Normally Closed Contacts”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690 V AC”,”value”:”690V AC”},{“name”:”Compatible with Series”,”normalizedValue”:”TeSys, TeSys K”,”value”:”TeSys, TeSys K”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Current AC”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Frame Size”,”normalizedValue”:”X, Y, Z”,”value”:”X, Y, Z”},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”110 A at Less than or Equal to 690 V AC conforming to IEC 60947″,”value”:”110 A at Less than or Equal to 690 V AC conforming to IEC 60947″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 176°F”,”value”:”-58 to 176°F (-50 to 80°C)”},{“name”:”Operating Altitude”,”normalizedValue”:”6,561.68 ft”,”value”:”6561.68 ft (2000 m)”},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm”,”value”:”Greater than 10 MOhm”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947-5-1; 600 V UL 60947-5-1; 600 V CSA C22.2 No 60947-5-1″,”value”:”690 V IEC 60947-5-1; 600 V UL 60947-5-1; 600 V CSA C22.2 No 60947-5-1″},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 122°F (50°C))”,”value”:”10 A (at 122°F (50°C))”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, CCC, UKCA, CB Scheme, CE”,”value”:”CB Scheme; CCC; UL; CSA; CE; UKCA”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG at Less than or Equal to 690 V conforming to IEC 60947″,”value”:”10 A gG at Less than or Equal to 690 V conforming to IEC 60947″},{“name”:”Protective Treatment”,”normalizedValue”:”TC IEC 60068″,”value”:”TC IEC 60068″},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP20 conforming to IEC 60529″,”value”:”IP20 conforming to IEC 60529″},{“name”:”Tightening Torque”,”normalizedValue”:”11.51 lbf.in (1.3 N.m) Philips No 2; 11.51 lbf.in (1.3 N.m) pozidriv No 2″,”value”:”11.51 lbf.in (1.3 N.m) Philips No 2; 11.51 lbf.in (1.3 N.m) pozidriv No 2″},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-13 to 122°F (-25 to 50°C)”,”value”:”-13 to 122°F (-25 to 50°C)”},{“name”:”Permissible Short-Time Rating”,”normalizedValue”:”80 A 1 s; 60 A 500 ms; 110 A 100 ms”,”value”:”80 A 1 s; 60 A 500 ms; 110 A 100 ms”},{“name”:”Range Compatibility”,”normalizedValue”:”TeSys K LC1K; TeSys K CA2K; TeSys K CA3K; TeSys K CA4K”,”value”:”TeSys K LC1K; TeSys K CA2K; TeSys K CA3K; TeSys K CA4K”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”690 V AC 25 to 400 Hz”,”value”:”690 V AC 25 to 400 Hz”},{“name”:”Pole Contact Composition”,”normalizedValue”:”2 NO”,”value”:”2 NO”},{“name”:”Non Overlap Distance”,”normalizedValue”:”0.02 in (0.5 mm)”,”value”:”0.02 in (0.5 mm)”},{“name”:”Product Name”,”normalizedValue”:”TeSys K”,”value”:”TeSys K”},{“name”:”Contacts Operation”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)rigid; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)rigid”,”value”:”screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)rigid; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)rigid”},{“name”:”Environmental Characteristic”,”normalizedValue”:”Normal environment”,”value”:”Normal environment”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.