IEC Auxiliary Contact

$28,45

Auxiliary Contact Block, Current AC 10 A, Number of Contacts 2, Mounting Front, Number of Normally Open Contacts 0, Maximum Voltage Rating 690V AC, Number of Normally Closed Contacts 2, Terminal Connection Type Screw Clamp Terminals, Compatible with Series TeSys, TeSys Deca, TeSys F, IP Rating IP20

9999 in stock

SKU: GRG2286672 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Auxiliary Contact Block”,”rank”:1,”value”:”Auxiliary Contact Block”},{“name”:”Number of NO Aux. Contacts”,”normalizedValue”:”0″,”rank”:3,”value”:”0″},{“name”:”Number of NC Aux. Contacts”,”normalizedValue”:”2″,”rank”:4,”value”:”2″},{“name”:”Amps”,”normalizedValue”:”10 A”,”rank”:5,”value”:”10 A”},{“name”:”Mounting”,”normalizedValue”:”Front”,”rank”:7,”value”:”Front”},{“name”:”For Use With”,”normalizedValue”:”Schenider LC1F Contactors”,”rank”:8,”value”:”Schenider LC1F Contactors”},{“name”:”Number of Contacts”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Max. Contact Blocks (No.)”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Voltage”,”normalizedValue”:”690V AC”,”value”:”690V AC”},{“name”:”Color”,”normalizedValue”:”Dark Gray”,”value”:”Dark Gray”},{“name”:”Height”,”normalizedValue”:”48 mm”,”value”:”48 mm”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, CB, CCC, EAC, UKCA”,”value”:”EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, CB, CCC, EAC, UKCA”},{“name”:”Depth”,”normalizedValue”:”42 mm”,”value”:”42 mm”},{“name”:”Width”,”normalizedValue”:”26 mm”,”value”:”26 mm”},{“name”:”Features”,”normalizedValue”:”Mercury Free, Toxic Heavy Metal Free”,”value”:”Mercury Free, Toxic Heavy Metal Free”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Number of Normally Closed Contacts”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Current AC”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Number of Normally Open Contacts”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690 V AC”,”value”:”690V AC”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Compatible with Series”,”normalizedValue”:”TeSys, TeSys Deca, TeSys F”,”value”:”TeSys, TeSys Deca, TeSys F”},{“name”:”Environmental Characteristic”,”normalizedValue”:”Normal environment”,”value”:”Normal environment”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, CCC, UKCA, CB, EAC”,”value”:”CB; UL; CSA; CCC; EAC; UKCA”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP20 conforming to IEC 60529″,”value”:”IP20 conforming to IEC 60529″},{“name”:”Contacts Operation”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Product Name”,”normalizedValue”:”TeSys Deca”,”value”:”TeSys Deca”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-76 to 176°F”,”value”:”-76 to 176°F (-60 to 80°C)”},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm”,”value”:”Greater than 10 MOhm”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Tightening Torque”,”normalizedValue”:”15.05 lbf.in (1.7 N.m) flat 6 mm; 15.05 lbf.in (1.7 N.m) Philips No 2; 15.05 lbf.in (1.7 N.m) pozidriv No 2″,”value”:”15.05 lbf.in (1.7 N.m) flat 6 mm; 15.05 lbf.in (1.7 N.m) Philips No 2; 15.05 lbf.in (1.7 N.m) pozidriv No 2″},{“name”:”Rated Operational Voltage”,”normalizedValue”:”690 V AC 25 to 400 Hz”,”value”:”690 V AC 25 to 400 Hz”},{“name”:”Operating Altitude”,”normalizedValue”:”9,842.52 ft”,”value”:”9842.52 ft (3000 m)”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact”,”value”:”1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact”},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1″,”value”:”140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1″},{“name”:”Mechanical Durability”,”normalizedValue”:”30 Mcycles”,”value”:”30 Mcycles”},{“name”:”Protective Treatment”,”normalizedValue”:”TH IEC 60068″,”value”:”TH IEC 60068″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”23 to 140°F (-5 to 60°C)”,”value”:”23 to 140°F (-5 to 60°C)”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 140°F (60°C))”,”value”:”10 A (at 140°F (60°C))”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Pole Contact Composition”,”normalizedValue”:”2 NC”,”value”:”2 NC”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible with cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end”,”value”:”screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible with cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end”},{“name”:”Permissible Short-Time Rating”,”normalizedValue”:”100 A 1 s; 120 A 500 ms; 140 A 100 ms”,”value”:”100 A 1 s; 120 A 500 ms; 140 A 100 ms”},{“name”:”Protection Type”,”normalizedValue”:”GG fuse 10 A”,”value”:”GG fuse 10 A”},{“name”:”Rated Operational Current”,”normalizedValue”:”6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13″,”value”:”6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13″},{“name”:”Range Compatibility”,”normalizedValue”:”TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D”,”value”:”TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947-5-1; 600 V UL; 600 V CSA”,”value”:”690 V IEC 60947-5-1; 600 V UL; 600 V CSA”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “IEC Auxiliary Contact”