IEC Auxiliary Contact

$19,39

Auxiliary Contact Block, Current AC 10 A, Number of Contacts 1, Mounting Front, Number of Normally Open Contacts 0, Maximum Voltage Rating 690V AC, Number of Normally Closed Contacts 1, Terminal Connection Type Screw Clamp Terminals, Compatible with Series TeSys, TeSys Deca, TeSys F, IP Rating IP20

9999 in stock

SKU: GRG0756411 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Auxiliary Contact Block”,”rank”:1,”value”:”Auxiliary Contact Block”},{“name”:”Number of NO Aux. Contacts”,”normalizedValue”:”0″,”rank”:3,”value”:”0″},{“name”:”Number of NC Aux. Contacts”,”normalizedValue”:”1″,”rank”:4,”value”:”1″},{“name”:”Amps”,”normalizedValue”:”10 A”,”rank”:5,”value”:”10 A”},{“name”:”Mounting”,”normalizedValue”:”Front”,”rank”:7,”value”:”Front”},{“name”:”For Use With”,”normalizedValue”:”Schenider LC1F Contactors”,”rank”:8,”value”:”Schenider LC1F Contactors”},{“name”:”Number of Contacts”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Max. Contact Blocks (No.)”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Voltage”,”normalizedValue”:”690V AC”,”value”:”690V AC”},{“name”:”Color”,”normalizedValue”:”Dark Gray”,”value”:”Dark Gray”},{“name”:”Height”,”normalizedValue”:”48 mm”,”value”:”48 mm”},{“name”:”Width”,”normalizedValue”:”13 mm”,”value”:”13 mm”},{“name”:”Depth”,”normalizedValue”:”35 mm”,”value”:”35 mm”},{“name”:”Features”,”normalizedValue”:”Mercury Free, Toxic Heavy Metal Free”,”value”:”Mercury Free, Toxic Heavy Metal Free”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, CB, CCC, EAC, UKCA”,”value”:”EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, CB, CCC, EAC, UKCA”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690 V AC”,”value”:”690V AC”},{“name”:”Compatible with Series”,”normalizedValue”:”TeSys, TeSys Deca, TeSys F”,”value”:”TeSys, TeSys Deca, TeSys F”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Number of Normally Closed Contacts”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Current AC”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Number of Normally Open Contacts”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947-5-1; 600 V UL; 600 V CSA”,”value”:”690 V IEC 60947-5-1; 600 V UL; 600 V CSA”},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1″,”value”:”140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1″},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact”,”value”:”1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-76 to 176°F”,”value”:”-76 to 176°F (-60 to 80°C)”},{“name”:”Environmental Characteristic”,”normalizedValue”:”Normal environment”,”value”:”Normal environment”},{“name”:”Range Compatibility”,”normalizedValue”:”TeSys Deca LC1D80/95 3P; TeSys Deca LC1D80 4P; TeSys Deca LC1D40008; TeSys Deca LC1D65008; TeSys F LC1F; TeSys Deca LC1D115″,”value”:”TeSys Deca LC1D80/95 3P; TeSys Deca LC1D80 4P; TeSys Deca LC1D40008; TeSys Deca LC1D65008; TeSys F LC1F; TeSys Deca LC1D115″},{“name”:”Tightening Torque”,”normalizedValue”:”15.05 lbf.in (1.7 N.m) flat 6 mm; 15.05 lbf.in (1.7 N.m) Philips No 2; 15.05 lbf.in (1.7 N.m) pozidriv No 2″,”value”:”15.05 lbf.in (1.7 N.m) flat 6 mm; 15.05 lbf.in (1.7 N.m) Philips No 2; 15.05 lbf.in (1.7 N.m) pozidriv No 2″},{“name”:”Operating Altitude”,”normalizedValue”:”9,842.52 ft”,”value”:”9842.52 ft (3000 m)”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”23 to 140°F (-5 to 60°C)”,”value”:”23 to 140°F (-5 to 60°C)”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible with cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end”,”value”:”screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible with cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end; screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²)rigid without cable end”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 140°F (60°C))”,”value”:”10 A (at 140°F (60°C))”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”690 V AC 25 to 400 Hz”,”value”:”690 V AC 25 to 400 Hz”},{“name”:”Permissible Short-Time Rating”,”normalizedValue”:”100 A 1 s; 120 A 500 ms; 140 A 100 ms”,”value”:”100 A 1 s; 120 A 500 ms; 140 A 100 ms”},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm”,”value”:”Greater than 10 MOhm”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Pole Contact Composition”,”normalizedValue”:”1 NC”,”value”:”1 NC”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Product Name”,”normalizedValue”:”TeSys Deca”,”value”:”TeSys Deca”},{“name”:”Protection Type”,”normalizedValue”:”GG fuse 10 A”,”value”:”GG fuse 10 A”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, CCC, UKCA, CB, EAC”,”value”:”CB; UL; CSA; CCC; EAC; UKCA”},{“name”:”Protective Treatment”,”normalizedValue”:”TH IEC 60068″,”value”:”TH IEC 60068″},{“name”:”Rated Operational Current”,”normalizedValue”:”6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13″,”value”:”6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13″},{“name”:”Contacts Operation”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Mechanical Durability”,”normalizedValue”:”30 Mcycles”,”value”:”30 Mcycles”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP20 conforming to IEC 60529″,”value”:”IP20 conforming to IEC 60529″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “IEC Auxiliary Contact”