Hot Water Circulating Pump, 1/2 hp, 208-230/460VAC, 3 Phase, Flange Connection, Bell & Gossett, Mfr#: 1EF047LF

$2962,40

Hydronic Circulating Pump, Compatible Intake Pipe Size 1 1/2 in, Connection Type Flange, Face to Face Dimension 11 1/2 in, Flange or Union Included Yes, For Use With Potable Systems Yes, Horsepower 1/2, Maximum Feet of Head 24 ft, Maximum Flow Rate @ 10 Feet of Head 90 gpm, Maximum Flow Rate @ 15 Feet of Head 85 gpm, Nameplate Voltage 208-230/460V AC, Number of Speeds 1, Phase Three, Pump Type 3-Piece, Series Family E-60, Maximum Flow Rate @ 20 Feet of Head 52 gpm, Series E608T, Amps 1.1/2.1 A

9999 in stock

Description

[{“name”:”Voltage”,”normalizedValue”:”208-240/460V AC”,”rank”:1,”value”:”208-240/460V AC”},{“name”:”Item”,”normalizedValue”:”Hydronic Circulating Pump”,”rank”:1,”value”:”Hydronic Circulating Pump”},{“name”:”HP”,”normalizedValue”:”1/2 hp”,”rank”:2,”value”:”1/2 hp”},{“name”:”Housing Material”,”normalizedValue”:”Cast iron”,”rank”:3,”value”:”Cast iron”},{“name”:”Phase – Pumps”,”normalizedValue”:”3″,”rank”:4,”value”:”3″},{“name”:”Phase”,”normalizedValue”:”Three”,”rank”:4,”value”:”Three”},{“name”:”Inlet/Outlet Size”,”normalizedValue”:”1-1/2 in”,”rank”:5,”value”:”1-1/2 in”},{“name”:”Pump Type”,”normalizedValue”:”3-Piece”,”rank”:6,”value”:”3-Piece”},{“name”:”Connection Style”,”normalizedValue”:”Flange”,”rank”:7,”value”:”Flange”},{“name”:”Max. GPM @ Head”,”normalizedValue”:”80 gpm @ 13 ft”,”rank”:8,”value”:”80 gpm @ 13 ft”},{“name”:”Min. GPM @ Head”,”normalizedValue”:”15 gpm @ 24 ft”,”rank”:9,”value”:”15 gpm @ 24 ft”},{“name”:”Series”,”normalizedValue”:”E608T”,”rank”:10,”value”:”E608T”},{“name”:”Loop Configuration”,”normalizedValue”:”Closed”,”value”:”Closed”},{“name”:”Drive Type”,”normalizedValue”:”Direct”,”value”:”Direct”},{“name”:”Width”,”normalizedValue”:”7-7/8 in”,”value”:”7 7/8 in”},{“name”:”Mechanical Seal”,”normalizedValue”:”EPR/Carbon/Silicon Carbide”,”value”:”EPR/Carbon/Silicon Carbide”},{“name”:”Compliance”,”normalizedValue”:”NSF-372, CSA”,”value”:”CSA, NSF-372″},{“name”:”Standards”,”normalizedValue”:”ISO 9001″,”value”:”ISO 9001″},{“name”:”Height”,”normalizedValue”:”11-1/2 in”,”value”:”11 1/2 in”},{“name”:”RPM”,”normalizedValue”:”1,750″,”value”:”1,750 RPM”},{“name”:”Amps”,”normalizedValue”:”1.1/2.1 A”,”value”:”1.1/2.1 A”},{“name”:”Shaft Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Max. Operating Pressure”,”normalizedValue”:”175 psi”,”value”:”175 psi”},{“name”:”Flange/Union Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Length”,”normalizedValue”:”21-1/2 in”,”value”:”21 1/2 in”},{“name”:”Impeller Material”,”normalizedValue”:”Bronze”,”value”:”Bronze”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Max. Temp.”,”normalizedValue”:”250 deg F”,”value”:”250 Degrees F”},{“name”:”Housing Material – Pumps”,”normalizedValue”:”Cast Iron”,”value”:”Cast Iron”},{“name”:”Shut-Off”,”normalizedValue”:”24 ft”,”value”:”24 ft”},{“name”:”Features”,”normalizedValue”:”Dimensional Interchangeability with Legacy Series 60, Leading Hydraulic Efficiency, Upgraded Unitized Mechanical Seal”,”value”:”Dimensional Interchangeability with Legacy Series 60, Leading Hydraulic Efficiency, Upgraded Unitized Mechanical Seal”},{“name”:”Thermal Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”HVAC Circulating Pump Type”,”normalizedValue”:”Hot Water Circulating Pump”,”value”:”Hot Water Circulating Pump”},{“name”:”Face to Face Dimension”,”normalizedValue”:”11-1/2 in”,”value”:”11 1/2 in”},{“name”:”Pump Mount”,”normalizedValue”:”In Line”,”value”:”In Line”},{“name”:”Number of Speeds”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Best Efficiency GPM @ Head”,”normalizedValue”:”52 gpm @ 20 ft”,”value”:”52 gpm @ 20 ft”},{“name”:”Voltage – Pumps”,”normalizedValue”:”208 to 230/460V AC”,”value”:”208 to 230/460V AC”},{“name”:”For Use With”,”normalizedValue”:”Potable Systems”,”value”:”Potable Systems”},{“name”:”Overall Width”,”normalizedValue”:”7.88 in”,”value”:”7.88 in”},{“name”:”Overall Length”,”normalizedValue”:”21-1/2 in”,”value”:”21.5 in”},{“name”:”Overall Height”,”normalizedValue”:”11-1/2 in”,”value”:”11.5 in”},{“name”:”Maximum Feet of Head”,”normalizedValue”:”24 ft”,”value”:”24 ft”},{“name”:”Connection Type”,”normalizedValue”:”Flange”,”value”:”Flange”},{“name”:”Compatible Media Type”,”normalizedValue”:”Water”,”value”:”Water”},{“name”:”Maximum Media Temperature”,”normalizedValue”:”225 deg F”,”value”:”225 Degrees F”},{“name”:”Compatible Intake Pipe Size”,”normalizedValue”:”1-1/2 in”,”value”:”1 1/2 in”},{“name”:”Series Family”,”normalizedValue”:”E-60″,”value”:”E-60″},{“name”:”Maximum RPM”,”normalizedValue”:”1,750 rpm”,”value”:”1,750 RPM”},{“name”:”Maximum Operating Pressure”,”normalizedValue”:”175 psi”,”value”:”175 psi”},{“name”:”Pump Housing Material”,”normalizedValue”:”Cast Iron”,”value”:”Cast Iron”},{“name”:”Maximum Flow Rate @ 20 Feet of Head”,”normalizedValue”:”52 gpm”,”value”:”52 gpm”},{“name”:”Minimum Media Temperature”,”normalizedValue”:”-10 deg F”,”value”:”-10 Degrees F”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Maximum Flow Rate @ 15 Feet of Head”,”normalizedValue”:”85 gpm”,”value”:”85 gpm”},{“name”:”Horsepower”,”normalizedValue”:”1/2″,”value”:”1/2″},{“name”:”Body Gasket Material”,”normalizedValue”:”Cellulose Fiber”,”value”:”Cellulose Fiber”},{“name”:”Flange or Union Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”For Use With Potable Systems”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Nameplate Voltage”,”normalizedValue”:”208-230/460V AC”,”value”:”208-230/460V AC”},{“name”:”Maximum Flow Rate @ 1 Feet of Head”,”normalizedValue”:”85 gpm”,”value”:”85 gpm”},{“name”:”Phase and Brand”,”normalizedValue”:”BELL u0026 GOSSETT Three Phase”,”value”:”BELL u0026 GOSSETT Three Phase”},{“name”:”Maximum Flow Rate @ 10 Feet of Head”,”normalizedValue”:”90 gpm”,”value”:”90 gpm”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Hot Water Circulating Pump, 1/2 hp, 208-230/460VAC, 3 Phase, Flange Connection, Bell & Gossett, Mfr#: 1EF047LF”