HVAC Circulating Pump, 1 hp, 115/208-230, 1 Phase, Flange Connection

$2356,90

Hydronic Circulating Pump, Compatible Intake Pipe Size 1 in, Connection Type FNPT, Face to Face Dimension 11 in, Flange or Union Included Not Applicable, For Use With Potable Systems No, Horsepower 1, Maximum Feet of Head 53 ft, Maximum Flow Rate @ 10 Feet of Head Not Applicable, Maximum Flow Rate @ 50 Feet of Head 37 gpm, Maximum Flow Rate @ 15 Feet of Head Not Applicable, Maximum Flow Rate @ 1 Foot of Head Not Applicable, Nameplate Voltage 115/208 to 230V AC, Phase Single, Series Family E90

9999 in stock

SKU: GRG9108145 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Hydronic Circulating Pump”,”rank”:1,”value”:”Hydronic Circulating Pump”},{“name”:”Voltage”,”normalizedValue”:”115/208-240V AC”,”rank”:2,”value”:”115/208-240V AC”},{“name”:”Phase”,”normalizedValue”:”Single”,”rank”:3,”value”:”Single”},{“name”:”Horsepower”,”normalizedValue”:”1″,”rank”:4,”value”:”1″},{“name”:”Inlet/Outlet Size”,”normalizedValue”:”1 in”,”rank”:5,”value”:”1 in”},{“name”:”Series”,”normalizedValue”:”E9020S”,”rank”:5,”value”:”E9020S”},{“name”:”Pump Type”,”normalizedValue”:”Closed Couple In Line Centrifugal Pump”,”rank”:6,”value”:”Closed Couple In Line Centrifugal Pump”},{“name”:”Max. GPM @ Head”,”normalizedValue”:”67 gpm @ 33 ft”,”rank”:8,”value”:”67 gpm @ 33 ft”},{“name”:”Maximum Feet of Head”,”normalizedValue”:”53 ft”,”rank”:8,”value”:”53 ft”},{“name”:”Connection Type”,”normalizedValue”:”FNPT”,”rank”:9,”value”:”FNPT”},{“name”:”Shaft Material”,”normalizedValue”:”Stainless Steel”,”value”:”Stainless Steel”},{“name”:”Frame”,”normalizedValue”:”NEMA 56J”,”value”:”NEMA 56J”},{“name”:”Shut-Off”,”normalizedValue”:”53 ft”,”value”:”53 ft”},{“name”:”Motor Type”,”normalizedValue”:”56J”,”value”:”56J”},{“name”:”Impeller Material”,”normalizedValue”:”ASTM”,”value”:”ASTM”},{“name”:”Motor Ambient Temp. Rating”,”normalizedValue”:”40 Degrees C”,”value”:”40 Degrees C”},{“name”:”Impeller Type”,”normalizedValue”:”Closed”,”value”:”Closed”},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Amps”,”normalizedValue”:”6.8 to 6.6/13.2″,”value”:”6.8 to 6.6/13.2″},{“name”:”Duty”,”normalizedValue”:”Continuous”,”value”:”Continuous”},{“name”:”Standards”,”normalizedValue”:”NEMA”,”value”:”NEMA”},{“name”:”Face to Face Dimension”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”Overall Height”,”normalizedValue”:”16-1/2 in”,”value”:”16.5 in”},{“name”:”Overall Length”,”normalizedValue”:”12-1/2 in”,”value”:”12.5 in”},{“name”:”Overall Width”,”normalizedValue”:”7-1/2 in”,”value”:”7.5 in”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Compatible Intake Pipe Size”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Maximum Media Temperature”,”normalizedValue”:”200 deg F”,”value”:”200 Degrees F”},{“name”:”For Use With Potable Systems”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Nameplate Voltage”,”normalizedValue”:”115/208 to 230V AC”,”value”:”115/208 to 230V AC”},{“name”:”Series Family”,”normalizedValue”:”E90″,”value”:”E90″},{“name”:”Motor Enclosure Design”,”normalizedValue”:”Open Drip-Proof”,”value”:”Open Drip-Proof”},{“name”:”Minimum Media Temperature”,”normalizedValue”:”100 deg F”,”value”:”100 Degrees F”},{“name”:”Compatible Discharge Pipe Size”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Compatible Media Type”,”normalizedValue”:”Water”,”value”:”Water”},{“name”:”Pump Mounting Position”,”normalizedValue”:”Horizontal, Vertical”,”value”:”Vertical/Horizontal”},{“name”:”Maximum Operating Pressure”,”normalizedValue”:”175 psi”,”value”:”175 psi”},{“name”:”Pipe to Flange or Union Connection Type”,”normalizedValue”:”FNPT”,”value”:”FNPT”},{“name”:”Flange or Union Included”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Flow Rate @ 20 Feet of Head”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Flow Rate @ 10 Feet of Head”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Flow Rate @ 15 Feet of Head”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Flow Rate @ 50 Feet of Head”,”normalizedValue”:”37 gpm”,”value”:”37 gpm”},{“name”:”Maximum Flow Rate @ 5 Feet of Head”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Flow Rate @ 1 Feet of Head”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Flow Rate @ 25 Feet of Head”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Flow Rate @ 40 Feet of Head”,”normalizedValue”:”57 gpm”,”value”:”57 gpm”},{“name”:”Maximum Flow Rate @ 30 Feet of Head”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Pump Housing Material”,”normalizedValue”:”Bronze Fitted”,”value”:”Bronze Fitted”},{“name”:”Maximum RPM”,”normalizedValue”:”3450″,”value”:”3450″},{“name”:”Body Gasket Material”,”normalizedValue”:”Carbon, EPR, Silicon Carbide”,”value”:”EPR, Carbon, Silicon Carbide”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “HVAC Circulating Pump, 1 hp, 115/208-230, 1 Phase, Flange Connection”