Gas Valve, NG/LP, Air Mixtures, 750 mV, 3.5 in wc, Standard Opening, Robertshaw, Mfr#: 710-501

$159,99

Gas Valve, Application Space Heaters, Current 0.2 A, Flow Direction Straight-Thru, For Media Liquid Propane, Natural Gas, Heating Capacity – Maximum 70,000 BtuH, Includes Conversion Kit Conversion Kit Not Included, Includes On/Off Switch On/Pilot/Off Switch Included, Includes Pilot Generator Kit Pilot Generator Kit Not Included, Includes Pressure Regulator Pressure Regulator Not Included, Includes Pressure Tap Pressure Tap Inlet Included, Includes Side Taps Side Taps Included

9999 in stock

SKU: GRG2957333 Categories: ,

Description

[{“name”:”BtuH Capacity”,”normalizedValue”:”70,000 BtuH”,”rank”:1,”value”:”70,000 BtuH”},{“name”:”Coil Volts”,”normalizedValue”:”750 mV”,”rank”:2,”value”:”750 mV”},{“name”:”Gas Type”,”normalizedValue”:”NG/LP, Air Mixtures”,”rank”:3,”value”:”NG/LP, Air Mixtures”},{“name”:”Inlet Size”,”normalizedValue”:”1/2 in”,”rank”:5,”value”:”1/2 in”},{“name”:”Outlet Size”,”normalizedValue”:”1/2 in”,”rank”:6,”value”:”1/2 in”},{“name”:”Reducer Bushing Kit”,”normalizedValue”:”1/2 X 3/8 in”,”rank”:7,”value”:”(2) 1/2 X 3/8 in”},{“name”:”Valve Type”,”normalizedValue”:”Standard Opening”,”rank”:8,”value”:”Standard Opening”},{“name”:”For Use With”,”normalizedValue”:”RV’s And Other Applications With Limited Space”,”rank”:9,”value”:”RV’s And Other Applications With Limited Space”},{“name”:”Amps AC”,”normalizedValue”:”0.2 A”,”rank”:10,”value”:”0.2 A”},{“name”:”Ambient Temp. Range”,”normalizedValue”:”-40 to 175 deg F”,”rank”:11,”value”:”-40 to 175 Degrees F”},{“name”:”Item”,”normalizedValue”:”Gas Valve”,”rank”:12,”value”:”Gas Valve”},{“name”:”LP Conversion Kit”,”normalizedValue”:”No”,”rank”:13,”value”:”No”},{“name”:”Pressure Setting Range”,”normalizedValue”:”3.5 in wc”,”rank”:14,”value”:”3.5 in wc”},{“name”:”Flow Direction”,”normalizedValue”:”Straight-Thru”,”rank”:20,”value”:”Straight-Thru”},{“name”:”Includes”,”normalizedValue”:”(2) 1/2 X 3/8 in Reducer Bushings”,”rank”:21,”value”:”(2) 1/2 X 3/8 in Reducer Bushings”},{“name”:”Inlet Pressure Tap”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Side Taps”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Max. Inlet Pressure”,”normalizedValue”:”0.5 psi”,”value”:”1/2 psi”},{“name”:”Standards”,”normalizedValue”:”RoHS compliant, NEMA, CSA”,”value”:”RoHS compliant, NEMA, CSA”},{“name”:”Port Connection Gender”,”normalizedValue”:”Female”,”value”:”Female”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Heating Capacity – Maximum”,”normalizedValue”:”70,000 BtuH”,”value”:”70,000 BtuH”},{“name”:”Includes Thermostat”,”normalizedValue”:”Mechanical Thermostat Not Included”,”value”:”Mechanical Thermostat Not Included”},{“name”:”Port Connection Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Pilot Port Connection Size”,”normalizedValue”:”1/4 in”,”value”:”1/4 in”},{“name”:”Manufacturer Series”,”normalizedValue”:”710″,”value”:”710″},{“name”:”Sensing Type”,”normalizedValue”:”Flame Sensor”,”value”:”Flame Sensor”},{“name”:”Application”,”normalizedValue”:”Space Heaters”,”value”:”Space Heaters”},{“name”:”Port Connection Size”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Includes On/Off Switch”,”normalizedValue”:”Off, On Switch Included, Pilot”,”value”:”On/Pilot/Off Switch Included”},{“name”:”Includes Pressure Tap”,”normalizedValue”:”Pressure Tap Inlet Included”,”value”:”Pressure Tap Inlet Included”},{“name”:”Includes Conversion Kit”,”normalizedValue”:”Conversion Kit Not Included”,”value”:”Conversion Kit Not Included”},{“name”:”Current”,”normalizedValue”:”0.2 A”,”value”:”0.2 A”},{“name”:”Installation Orientation”,”normalizedValue”:”Versatile”,”value”:”Versatile”},{“name”:”Reducer Bushings Included”,”normalizedValue”:”(2) 1/2 x 3/8 in”,”value”:”(2) 1/2 x 3/8 in”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”175 deg F”,”value”:”175 Degrees F”},{“name”:”Includes Pressure Regulator”,”normalizedValue”:”Pressure Regulator Not Included”,”value”:”Pressure Regulator Not Included”},{“name”:”Pilot Port Connection Type”,”normalizedValue”:”Compression”,”value”:”Compression”},{“name”:”Includes Side Taps”,”normalizedValue”:”Side Taps Included”,”value”:”Side Taps Included”},{“name”:”For Media”,”normalizedValue”:”Liquid Propane, Natural Gas”,”value”:”Liquid Propane, Natural Gas”},{“name”:”Includes Pilot Generator Kit”,”normalizedValue”:”Pilot Generator Kit Not Included”,”value”:”Pilot Generator Kit Not Included”},{“name”:”Voltage”,”normalizedValue”:”0.75 V”,”value”:”750mV”},{“name”:”Pilot Type”,”normalizedValue”:”Standing Pilot”,”value”:”Standing Pilot”},{“name”:”Valve Design”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Opening Characteristic”,”normalizedValue”:”Fast Opening”,”value”:”Fast Opening”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Gas Valve, NG/LP, Air Mixtures, 750 mV, 3.5 in wc, Standard Opening, Robertshaw, Mfr#: 710-501”