Description
[{“name”:”Item”,”normalizedValue”:”GFCI Receptacle”,”value”:”GFCI Receptacle”},{“name”:”Weather Resistant – Plugs and Receptacles”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Power Indicator”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Mounting Type”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Amps – Plugs and Receptacles”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”NEMA Receptacle Configuration – Plugs and Receptacles”,”normalizedValue”:”5-20R”,”value”:”5-20R”},{“name”:”HP”,”normalizedValue”:”1 hp”,”value”:”1 hp”},{“name”:”Surge Suppression”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Tamper Resistant”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Wiring Method”,”normalizedValue”:”Back, Side”,”value”:”Back, Side”},{“name”:”Reset Type”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Number of Wires”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Amps”,”normalizedValue”:”20″,”value”:”20A”},{“name”:”Color”,”normalizedValue”:”Ivory”,”value”:”Ivory”},{“name”:”Voltage”,”normalizedValue”:”125VAC”,”value”:”125VAC”},{“name”:”Application Environment”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Outlet Type”,”normalizedValue”:”Decorator”,”value”:”Decorator”},{“name”:”Standards”,”normalizedValue”:”NEC”,”value”:”NEC”},{“name”:”Outlet Type – Plugs and Receptacles”,”normalizedValue”:”Decorator Duplex”,”value”:”Decorator Duplex”},{“name”:”Mounting Type – Plugs and Receptacles”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Weather Resistant”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Wiring Method – Plugs and Receptacles”,”normalizedValue”:”Side, Back”,”value”:”Back and Side”},{“name”:”NEMA Configuration”,”normalizedValue”:”5-20″,”value”:”5-20″},{“name”:”Voltage – Plugs and Receptacles”,”normalizedValue”:”125V AC”,”value”:”125V AC”},{“name”:”Color – Plugs and Receptacles”,”normalizedValue”:”Ivory”,”value”:”Ivory”},{“name”:”Item – Plugs and Receptacles”,”normalizedValue”:”Receptacle”,”value”:”Receptacle”},{“name”:”Self-Testing”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Amps – Plugs and Receptacles”,”normalizedValue”:”20″,”value”:”20″},{“name”:”Housing Material”,”normalizedValue”:”Zytel 101″,”value”:”Zytel 101″},{“name”:”Market”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Features”,”normalizedValue”:”Power Indicator, Trip Indicator, Automatically Monitors The Ability to Provide GFCI Protection Every 60 sec., Provides Power Denial If The Unit Can No Longer Provide Protection, Tamper Resistant, Weatherproof”,”value”:”Power Indicator, Trip Indicator, Automatically Monitors The Ability to Provide GFCI Protection Every 60 sec., Provides Power Denial If The Unit Can No Longer Provide Protection, Tamper Resistant, Weatherproof”},{“name”:”Mount Hole Center-to-Center Height”,”normalizedValue”:”3.3 in”,”value”:”3.3 in”},{“name”:”Face Plate Width”,”normalizedValue”:”1.8 in”,”value”:”1.8 in”},{“name”:”Shrouded”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Housing Color”,”normalizedValue”:”Ivory”,”value”:”Ivory”},{“name”:”Cover Type”,”normalizedValue”:”No Cover”,”value”:”No Cover”},{“name”:”GFCI”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Resistance Properties”,”normalizedValue”:”Tamper Resistant, Weather Resistant”,”value”:”Tamper Resistant, Weather Resistant”},{“name”:”Current Rating”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Contact Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Surge Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Polarized”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Wire Connection Type”,”normalizedValue”:”Screw Terminals”,”value”:”Screw Terminals”},{“name”:”Grade”,”normalizedValue”:”General Use”,”value”:”General Use”},{“name”:”Voltage Rating”,”normalizedValue”:”125 V”,”value”:”125V AC”},{“name”:”Receptacle Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Mount Type”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Face Plate Height”,”normalizedValue”:”2.8 in”,”value”:”2.8 in”},{“name”:”Includes”,”normalizedValue”:”Mounting Hardware”,”value”:”Mounting Hardware”},{“name”:”AFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Additional Electrical Protections”,”normalizedValue”:”GFCI”,”value”:”GFCI”},{“name”:”Grounding”,”normalizedValue”:”Grounded”,”value”:”Grounded”},{“name”:”Includes Mounting Hardware”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Connection Orientation”,”normalizedValue”:”Straight”,”value”:”Straight”},{“name”:”Horsepower Rating”,”normalizedValue”:”1 HP”,”value”:”1 hp”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Number of Gangs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-20R”,”value”:”5-20R”},{“name”:”Flange Type”,”normalizedValue”:”Non-Flanged”,”value”:”Non-Flanged”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Self Testing”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Type”,”normalizedValue”:”Tamper-Resistant, Weather Resistant”,”value”:”Tamper-Resistant, Weather Resistant”},{“name”:”Current / Amperage Rating”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Series”,”normalizedValue”:”Heavy Duty”,”value”:”Heavy Duty”},{“name”:”Amperage Rating”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Style”,”normalizedValue”:”Standard”,”value”:”Standard”},{“name”:”Nema Rating”,”normalizedValue”:”5-20R”,”value”:”5-20R”},{“name”:”Voltage Rating Description”,”normalizedValue”:”125 V”,”value”:”125 V”},{“name”:”Industry Standard(s)”,”normalizedValue”:”Meets All NEC® Requirements”,”value”:”Meets All NEC® Requirements”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.