GFCI Rceptcle, Commer., Brwn, 15A, 0.5 HP

$41,35

AUTOGUARD® Self Test Technology 1st introduced by Hubbell over 10 years ago…self test monitoring now required in 2015 UL 943 GFCI Safety Standard… Hubbell AUTOGUARD® GFCI receptacles continually test and monitor for “people protection capability” automatically. This patented safety feature includes disconnecting power to the receptacle if critical components are damaged and GFCI protection is lost. GFCI auto-monitoring is conducted continuously within every 30 seconds. Also, clear visual indicators are provided on the device face representing power status, trip condition, ground fault condition and end of life status. In addition, for added safety, power will be denied to the receptacle face if reverse wiring of line and load was to occur.
• Audible SNAP, indicates solid connection
• Patented shutter design for tamper-resistant protection
• Meets NEC requirements for TR (517-18c) and WR (406.9), UV and corrosion resistance for harsh and damp applications
• Patented AUTOGUARD® self test technology
• Protects against line and load reversal, no power to the face or downstream if device is miswired

9999 in stock

SKU: GRG4843496 Category:

Description

[{“name”:”Item”,”normalizedValue”:”GFCI Receptacle”,”rank”:1,”value”:”GFCI Receptacle”},{“name”:”Connection Orientation”,”normalizedValue”:”Straight”,”rank”:2,”value”:”Straight”},{“name”:”Cover Type”,”normalizedValue”:”No Cover”,”rank”:3,”value”:”No Cover”},{“name”:”Current Rating”,”normalizedValue”:”15 A”,”rank”:4,”value”:”15 A”},{“name”:”Phase”,”normalizedValue”:”Single”,”rank”:5,”value”:”Single”},{“name”:”GFCI”,”normalizedValue”:”Yes”,”rank”:5,”value”:”Yes”},{“name”:”Grounding”,”normalizedValue”:”Grounded”,”rank”:6,”value”:”Grounded”},{“name”:”Housing Color”,”normalizedValue”:”Brown”,”rank”:7,”value”:”Brown”},{“name”:”Housing Material”,”normalizedValue”:”Nylon”,”rank”:8,”value”:”Nylon”},{“name”:”Mounting Type”,”normalizedValue”:”Flush”,”rank”:9,”value”:”Flush”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”rank”:10,”value”:”1″},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”rank”:11,”value”:”5-15R”},{“name”:”Material”,”normalizedValue”:”Nylon”,”rank”:11,”value”:”Nylon”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:12,”value”:”2″},{“name”:”Number of Wires”,”normalizedValue”:”3″,”rank”:13,”value”:”3″},{“name”:”Polarized”,”normalizedValue”:”Yes”,”rank”:14,”value”:”Yes”},{“name”:”Standards”,”normalizedValue”:”NEC”,”rank”:15,”value”:”NEC”},{“name”:”Amps”,”normalizedValue”:”15″,”value”:”15A”},{“name”:”Weather Resistant”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Wiring Method – Plugs and Receptacles”,”normalizedValue”:”Modular”,”value”:”Modular”},{“name”:”Color”,”normalizedValue”:”Brown”,”value”:”Brown”},{“name”:”Voltage – Plugs and Receptacles”,”normalizedValue”:”125 V”,”value”:”125V AC”},{“name”:”Weather Resistant – Plugs and Receptacles”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”HP”,”normalizedValue”:”0.5 hp”,”value”:”0.5 hp”},{“name”:”Wiring Method”,”normalizedValue”:”Back, Side”,”value”:”Back, Side”},{“name”:”NEMA Receptacle Configuration – Plugs and Receptacles”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Outlet Type – Plugs and Receptacles”,”normalizedValue”:”Decorator Duplex”,”value”:”Decorator Duplex”},{“name”:”Surge Suppression”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Amps – Plugs and Receptacles”,”normalizedValue”:”15 A”,”value”:”15 A”},{“name”:”Item – Plugs and Receptacles”,”normalizedValue”:”Receptacle”,”value”:”Receptacle”},{“name”:”Self-Testing”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Reset Type”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Tamper Resistant”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Voltage”,”normalizedValue”:”125VAC”,”value”:”125VAC”},{“name”:”Color – Plugs and Receptacles”,”normalizedValue”:”Brown”,”value”:”Brown”},{“name”:”NEMA Configuration”,”normalizedValue”:”5-15″,”value”:”5-15″},{“name”:”Amps – Plugs and Receptacles”,”normalizedValue”:”15″,”value”:”15″},{“name”:”Power Indicator”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Outlet Type”,”normalizedValue”:”Decorator”,”value”:”Decorator”},{“name”:”Mounting Type – Plugs and Receptacles”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Special Features”,”normalizedValue”:”Ground Fault Indicator”,”value”:”Ground Fault Indicator”},{“name”:”Application Environment”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Receptacle Type”,”normalizedValue”:”Decorator Duplex”,”value”:”Decorator Duplex”},{“name”:”Surge Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Self Testing”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Features”,”normalizedValue”:”Tamper and Weather Resistant SnapConnect”,”value”:”Tamper and Weather Resistant SnapConnect”},{“name”:”Resistance Properties”,”normalizedValue”:”Tamper Resistant, Weather Resistant”,”value”:”Tamper Resistant, Weather Resistant”},{“name”:”Maximum Wire Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Hub Type”,”normalizedValue”:”Feed Through”,”value”:”Feed Through”},{“name”:”Face Plate Width”,”normalizedValue”:”1.8 in”,”value”:”1.8 in”},{“name”:”Face Plate Height”,”normalizedValue”:”2.8 in”,”value”:”2.8 in”},{“name”:”Includes”,”normalizedValue”:”Mounting Hardware, Wall Plate”,”value”:”Mounting Hardware, Wall Plate”},{“name”:”Contact Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Market”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Includes Mounting Hardware”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Mount Hole Center-to-Center Height”,”normalizedValue”:”3.3 in”,”value”:”3.3 in”},{“name”:”Number of Gangs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Horsepower Rating”,”normalizedValue”:”0.5 HP”,”value”:”1/2 hp”},{“name”:”AFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Voltage Rating”,”normalizedValue”:”125 V AC”,”value”:”125V AC”},{“name”:”Shrouded”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Mount Type”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Overall Depth”,”normalizedValue”:”1-1/2 in”,”value”:”1.5 in”},{“name”:”Flange Type”,”normalizedValue”:”Non-Flanged”,”value”:”Non-Flanged”},{“name”:”Grade”,”normalizedValue”:”General Use”,”value”:”General Use”},{“name”:”Type”,”normalizedValue”:”Standard”,”value”:”Standard”},{“name”:”Height”,”normalizedValue”:”1.47 in”,”value”:”1.47 in”},{“name”:”Style”,”normalizedValue”:”Standard”,”value”:”Standard”},{“name”:”Horsepower – Maximum”,”normalizedValue”:”0.5″,”value”:”0.5″},{“name”:”Series”,”normalizedValue”:”Hospital Grade”,”value”:”Hospital Grade”},{“name”:”Industry Standard(s)”,”normalizedValue”:”Meets All NEC® Requirements”,”value”:”Meets All NEC® Requirements”},{“name”:”Width”,”normalizedValue”:”1.77 in”,”value”:”1.77 in”},{“name”:”Wire Size”,”normalizedValue”:”#12 AWG”,”value”:”#12 AWG”},{“name”:”Nema Rating”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Item Type”,”normalizedValue”:”Self test GFCI receptacle”,”value”:”Self test GFCI receptacle”},{“name”:”Amperage Rating”,”normalizedValue”:”15 A”,”value”:”15 A”},{“name”:”Current / Amperage Rating”,”normalizedValue”:”15 A”,”value”:”15 A”},{“name”:”Application”,”normalizedValue”:”Commercial Hospital Grade”,”value”:”Commercial Hospital Grade”},{“name”:”Dimensions”,”normalizedValue”:”3.28 in x 1.77 in x 1.47 in”,”value”:”3.28 in x 1.77 in x 1.47 in”},{“name”:”Voltage Rating Description”,”normalizedValue”:”125 V”,”value”:”125 V”},{“name”:”Wattage”,”normalizedValue”:”1875 W”,”value”:”1875 W”},{“name”:”Length”,”normalizedValue”:”3.28 in”,”value”:”3.28 in”},{“name”:”Environmental Conditions”,”normalizedValue”:”Weather Resistant”,”value”:”Weather Resistant”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “GFCI Rceptcle, Commer., Brwn, 15A, 0.5 HP”