Description
[{“name”:”Item”,”normalizedValue”:”Force”,”rank”:1,”value”:”Force”},{“name”:”Input Voltage”,”normalizedValue”:”100 to 240 V AC”,”rank”:2,”value”:”100 to 240 V AC”},{“name”:”Phase – Electrical”,”normalizedValue”:”Single”,”rank”:3,”value”:”Single”},{“name”:”Output Voltage”,”normalizedValue”:”12V DC”,”rank”:4,”value”:”12V DC”},{“name”:”Amps”,”normalizedValue”:”1.5 to 2.3 A”,”rank”:5,”value”:”1.5 to 2.3 A”},{“name”:”Power Rating”,”normalizedValue”:”100 W”,”rank”:5,”value”:”100W”},{“name”:”Output Amps”,”normalizedValue”:”8.5″,”rank”:6,”value”:”8.5″},{“name”:”Mounting”,”normalizedValue”:”Panel”,”rank”:7,”value”:”Panel”},{“name”:”Style”,”normalizedValue”:”Switching”,”rank”:8,”value”:”Switching”},{“name”:”Case Material”,”normalizedValue”:”Aluminum Case”,”rank”:9,”value”:”Aluminum Case”},{“name”:”Height”,”normalizedValue”:”30 mm”,”rank”:10,”value”:”30 mm”},{“name”:”NEMA Rating”,”normalizedValue”:”Not Applicable”,”value”:”Not Applicable”},{“name”:”Ripple Volts Regulation”,”normalizedValue”:”Less Than 120mV”,”value”:”Less Than 120mV”},{“name”:”Status Indicator”,”normalizedValue”:”Green LED”,”value”:”Green LED”},{“name”:”Load Regulation”,”normalizedValue”:”Less Than 0.5%”,”value”:”Less Than 0.5%”},{“name”:”Connection”,”normalizedValue”:”Screw”,”value”:”Screw”},{“name”:”Width”,”normalizedValue”:”97 mm”,”value”:”97 mm”},{“name”:”Temp. Range”,”normalizedValue”:”-30 to 50°C (without Derating), 50 to 70°C (with Current Derating)”,”value”:”-30 to 50°C (without Derating), 50 to 70°C (with Current Derating)”},{“name”:”Hold Up Time”,”normalizedValue”:”Greater Than 20 msec at 115 V AC, Greater Than 40 msec at 230 V AC”,”value”:”Greater Than 20 msec at 115 V AC, Greater Than 40 msec at 230 V AC”},{“name”:”Peak Amps”,”normalizedValue”:”45 A at 115 V AC, 85 A at 230 V AC”,”value”:”45 A at 115 V AC, 85 A at 230 V AC”},{“name”:”Operating Temp. Range”,”normalizedValue”:”-30 to 70 deg C”,”value”:”-30 Degrees to 70 Degrees C”},{“name”:”Protection”,”normalizedValue”:”Overload and Short-Circuits Automatic Reset, Over Temperature Manual Reset , Overvoltage Manual Reset”,”value”:”Overload and Short-Circuits Automatic Reset, Over Temperature Manual Reset , Overvoltage Manual Reset”},{“name”:”Standards”,”normalizedValue”:”CB Scheme, CE, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, CSA C22.2 No 62368-1, CULus, EAC, EN 55016-1-2, EN 55016-2-3, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61010-1, EN 61010-2-201, EN 61204-3, EN 62368-1, EN/IEC 61000-4-11, EN/IEC 62368-1, IEC 60068-2-6, IEC 60721-3-3, KC, RCM, REACH Complaint, RoHS Complaint, UL 61010-1, UL 61010-2-201, UL 62368-1″,”value”:”CB Scheme, CE, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, CSA C22.2 No 62368-1, CULus, EAC, EN 55016-1-2, EN 55016-2-3, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61010-1, EN 61010-2-201, EN 61204-3, EN 62368-1, EN/IEC 61000-4-11, EN/IEC 62368-1, IEC 60068-2-6, IEC 60721-3-3, KC, RCM, REACH Complaint, RoHS Complaint, UL 61010-1, UL 61010-2-201, UL 62368-1″},{“name”:”Hz”,”normalizedValue”:”50 to 60 Hz”,”value”:”50 to 60 Hz”},{“name”:”Depth”,”normalizedValue”:”129 mm”,”value”:”129 mm”},{“name”:”Output Noise”,”normalizedValue”:”Less than 120 mV”,”value”:”Less Than 120 mV”},{“name”:”Line Regulation”,”normalizedValue”:”Less Than 1%”,”value”:”Less Than 1%”},{“name”:”IP Rating”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Features”,”normalizedValue”:”Efficiency 88% at 230 V AC, Green Premium Product, Integrated Fuse, Mercury Free, Parallel and Serial Output Coupling, Relative Humidity 95% Without Condensation”,”value”:”Efficiency 88% at 230 V AC, Green Premium Product, Integrated Fuse, Mercury Free, Parallel and Serial Output Coupling, Relative Humidity 95% Without Condensation”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.