Expansion Module Ac

$329,99

Expansion Module Ac

9999 in stock

SKU: GRG0862648 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Expansion Module Ac”,”rank”:1,”value”:”Expansion Module Ac”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Height”,”normalizedValue”:”61 mm”,”value”:”61 mm”},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No 14 || IACS E10 || IEC 60947-4-1 || UL 508 || EN 60947-4-1″,”value”:”CSA C22.2 No 14 || IACS E10 || IEC 60947-4-1 || UL 508 || EN 60947-4-1″},{“name”:”Depth”,”normalizedValue”:”120.7 mm”,”value”:”120.7 mm”},{“name”:”Compatibility Code”,”normalizedValue”:”LTME”,”value”:”LTME”},{“name”:”Pollution Degree”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Device Short Name”,”normalizedValue”:”LTME”,”value”:”LTME”},{“name”:”Maximum Operating Frequency”,”normalizedValue”:”2 Hz”,”value”:”2 Hz”},{“name”:”Tightening Torque”,”normalizedValue”:”control circuit 0.5-0.6 N.m flat 3 mm”,”value”:”control circuit 0.5-0.6 N.m flat 3 mm”},{“name”:”Connections – Terminals”,”normalizedValue”:”control circuit connector 1 0.25-2.5 mm² AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24 to AWG 14)solid without cable end”,”value”:”control circuit connector 1 0.25-2.5 mm² AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24 to AWG 14)solid without cable end”},{“name”:”Mechanical Robustness”,”normalizedValue”:”shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 || vibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6″,”value”:”shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 || vibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6″},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Range Compatibility”,”normalizedValue”:”TeSys (TeSys T) LTMR motor controller”,”value”:”TeSys (TeSys T) LTMR motor controller”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1″,”value”:”4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-80°C”,”value”:”-40-80°C”},{“name”:”Operating Altitude”,”normalizedValue”:”<= 6561.68 ft (2000 m) without derating","value":"<= 6561.68 ft (2000 m) without derating"},{"name":"Protective Treatment","normalizedValue":"12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068","value":"12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068"},{"name":"Overvoltage Category","normalizedValue":"III","value":"III"},{"name":"Measurement Accuracy","normalizedValue":"1 % voltage 100 to 830 V) || 3 % power factor || 5 % active and reactive power","value":"1 % voltage 100 to 830 V) || 3 % power factor || 5 % active and reactive power"},{"name":"Product Name","normalizedValue":"TeSys T","value":"TeSys T"},{"name":"[Ui] Rated Insulation Voltage","normalizedValue":"690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508","value":"690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508"},{"name":"Product Certifications","normalizedValue":"LROS (Lloyds register of shipping) || ATEX || NOM || EAC || RMRoS || GL || UL || DNV || BV || RINA || KERI || C-tick || CSA || CCC || ABS","value":"LROS (Lloyds register of shipping) || ATEX || NOM || EAC || RMRoS || GL || UL || DNV || BV || RINA || KERI || C-tick || CSA || CCC || ABS"},{"name":"Maximum Operating Rate","normalizedValue":"1800 cyc/h","value":"1800 cyc/h"},{"name":"Metering Type","normalizedValue":"P3 ||, imbalance voltage || active power P, P1, P2 calculated active and reactive energy || voltage U21, U32, U13, V1, V2, V3 || reactive power Q, Q1, Q2, Q3 || frequency || power factor","value":"imbalance voltage || active power P, P1, P2, P3 || calculated active and reactive energy (+/- W.h, +/- VAR.h) || voltage U21, U32, U13, V1, V2, V3 || reactive power Q, Q1, Q2, Q3 || frequency || power factor"},{"name":"Ip Degree Of Protection","normalizedValue":"IP20","value":"IP20"},{"name":"Device Application","normalizedValue":"equipment monitoring and control","value":"equipment monitoring and control"},{"name":"Connection Pitch","normalizedValue":"5.08 mm","value":"5.08 mm"},{"name":"Electromagnetic Compatibility","normalizedValue":"electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5","value":"electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5"},{"name":"Logic Input Number","normalizedValue":"4","value":"4"},{"name":"Current State 1 Guaranteed","normalizedValue":"logic input 79 to 264 V <= 15 mA 25 ms","value":"logic input 79 to 264 V <= 15 mA 25 ms"},{"name":"Ambient Air Temperature For Operation","normalizedValue":"-20-60°C","value":"-20-60°C"},{"name":"Current State 0 Guaranteed","normalizedValue":"logic input 0 to 40 V 2 to 15 mA 25 ms","value":"logic input 0 to 40 V 2 to 15 mA 25 ms"},{"name":"Input Current","normalizedValue":"3.1 mA 100 V || 7.5 mA 240 V","value":"3.1 mA 100 V || 7.5 mA 240 V"},{"name":"Fire Resistance","normalizedValue":"650°C EN, IEC 60695-2-12 || 960°C UL 94","value":"650°C EN/IEC 60695-2-12 || 960°C UL 94"},{"name":"Product Or Component Type","normalizedValue":"module","value":"extension module"},{"name":"Supply","normalizedValue":"via the controller","value":"via the controller"},{"name":"Country of Origin (subject to change)","normalizedValue":"China","value":"China"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Expansion Module Ac”