Description
[{“name”:”Item”,”normalizedValue”:”Enclosed Power Supply”,”value”:”Enclosed Power Supply”},{“name”:”Max. Amps”,”normalizedValue”:”300VA”,”value”:”300VA”},{“name”:”Length (In.)”,”normalizedValue”:”12-1/8″,”value”:”12.125″},{“name”:”Width (In.)”,”normalizedValue”:”12-1/8″,”value”:”12.125″},{“name”:”Voltage”,”normalizedValue”:”120 Vac to 24 Vac @ 100 VA”,”value”:”120 Vac to 24 Vac @ 100 VA”},{“name”:”Primary”,”normalizedValue”:”120 Vac to 24 Vac”,”value”:”120 Vac to 24 Vac”},{“name”:”Approvals”,”normalizedValue”:”Class 2 (UL Approved UL5085-3), UL916, C-UL, CE”,”value”:”Class 2 (UL Approved UL5085-3), UL916, C-UL, CE”},{“name”:”Dimensions”,”normalizedValue”:”12-1/8 in H x 12-1/8 in W x 6 in D”,”value”:”12.125\” H x 12.125\”” W x 6.000\”” D””},{“”name””:””Standby Wattage””,””normalizedValue””:””16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac””,””value””:””16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac””},{“”name””:””24 Vac ON/OFF””,””normalizedValue””:””On / Off Switch \u0026 Breaker””,””value””:””On / Off Switch \u0026 Breaker””},{“”name””:””Full Load Primary Current””,””normalizedValue””:””2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac””,””value””:””2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac””},{“”name””:””Transformer””,””normalizedValue””:””One (1) 300 VA””,””value””:””One (1) 300 VA””},{“”name””:””3 Secondaries””,””normalizedValue””:””24 Vac, with LED Indicators 4 Amp breaker for each output””,””value””:””24 Vac, with LED Indicators 4 Amp breaker for each output””},{“”name””:””Input””,””normalizedValue””:””120 Vac to 24 Vac””,””value””:””120 Vac to 24 Vac””},{“”name””:””Secondary Output Voltage vs. Load””,””normalizedValue””:””24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp””,””value””:””24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp””},{“”name””:””Housing””,””normalizedValue””:””NEMA1 Metal Enclosure””,””value””:””NEMA1 Metal Enclosure””},{“”name””:””Ambient Temperature Derating””,””normalizedValue””:””4A up to 40? C , 3A up to 50? C , 2A up to 55? C””,””value””:””4A up to 40? C , 3A up to 50? C , 2A up to 55? C””},{“”name””:””Over Current Protection””,””normalizedValue””:””Circuit Breaker””,””value””:””Circuit Breaker””},{“”name””:””Output””,””normalizedValue””:””3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire.””,””value””:””3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire.””},{“”name””:””Frequency””,””normalizedValue””:””50/60 Hz””,””value””:””50/60 Hz””},{“”name””:””Country of Origin (subject to change)””,””normalizedValue””:””United States””,””value””:””United States””},{“”name””:””Package Quantity””,””normalizedValue””:””1″”,””value””:””1″”}]”

Reviews
There are no reviews yet.