Description
[{“name”:”Item”,”normalizedValue”:”Electronic protection module – 28..28.8″,”rank”:1,”value”:”Electronic protection module – 28..28.8″},{“name”:”Input Voltage”,”normalizedValue”:”24…28.8 V DC”,”value”:”24…28.8 V DC”},{“name”:”Standards”,”normalizedValue”:”UL 508 || CSA C22.2 No 60950-1″,”value”:”UL 508 || CSA C22.2 No 60950-1″},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m)”,”value”:”6561.68 ft (2000 m)”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-85 DegC”,”value”:”-40-85 DegC”},{“name”:”Fixing Mode”,”normalizedValue”:”by clips 35 mm symmetrical DIN rail vertical || on panel”,”value”:”by clips 35 mm symmetrical DIN rail vertical || on panel”},{“name”:”Input Current”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Connections – Terminals”,”normalizedValue”:”input connection screw type terminals 4 x 0.5…4 x 10 mm² AWG 20…AWG 8 || diagnostic relay removable screw terminal block 1 x 2.5 mm² AWG 14 || output connection screw type terminals 8 x 0.5…8 x 4 mm² AWG 20…AWG 10″,”value”:”input connection screw type terminals 4 x 0.5…4 x 10 mm² AWG 20…AWG 8 || diagnostic relay removable screw terminal block 1 x 2.5 mm² AWG 14 || output connection screw type terminals 8 x 0.5…8 x 4 mm² AWG 20…AWG 10″},{“name”:”Dielectric Strength”,”normalizedValue”:”500 V between input and ground || 500 V between output and ground”,”value”:”500 V between input and ground || 500 V between output and ground”},{“name”:”Relative humidity”,”normalizedValue”:”0-90 % during operation || 0-95 % during storage”,”value”:”0-90 % during operation || 0-95 % during storage”},{“name”:”Number Of Output Channels”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Product Certifications”,”normalizedValue”:”RCM || EAC”,”value”:”RCM || EAC”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Vibration Resistance”,”normalizedValue”:”2 gn 11.9-150 Hz)EN/IEC 61131-2 || 3.5 mm 3-11.9 Hz)EN/IEC 61131-2″,”value”:”2 gn 11.9-150 Hz)EN/IEC 61131-2 || 3.5 mm 3-11.9 Hz)EN/IEC 61131-2″},{“name”:”Output Voltage”,”normalizedValue”:”(Uin-0.3) V DC”,”value”:”(Uin-0.3) V DC”},{“name”:”Complementary Function”,”normalizedValue”:”2-pole breaking by channel”,”value”:”2-pole breaking by channel”},{“name”:”Breaking Capacity”,”normalizedValue”:”1000 A 32 V DC by fuse”,”value”:”1000 A 32 V DC by fuse”},{“name”:”Maximum Output Current”,”normalizedValue”:”10 A per channel, rating: 1/2.5/4/5/7/8/10″,”value”:”10 A per channel, rating: 1/2.5/4/5/7/8/10″},{“name”:”Overvoltage Category”,”normalizedValue”:”class II VDE 0106-1″,”value”:”class II VDE 0106-1″},{“name”:”Environmental Characteristic”,”normalizedValue”:”EMC EN 61000-6-3 || EMC EN/IEC 61000-6-2 || safety EN/IEC 60950-1 || safety EN/IEC 61204-3″,”value”:”EMC EN 61000-6-3 || EMC EN/IEC 61000-6-2 || safety EN/IEC 60950-1 || safety EN/IEC 61204-3″},{“name”:”Input Voltage Limits”,”normalizedValue”:”19…32 V”,”value”:”19…32 V”},{“name”:”Name Of Test”,”normalizedValue”:”electrostatic discharges EN/IEC 61000-4-2 || emission EN 61000-6-3 || induced electromagnetic field EN/IEC 61000-4-6 level 3 || radiated electromagnetic field EN/IEC 61000-4-3 level 3 || rapid transient IEC 61000-4-4 level 3 || surge EN/IEC 61000-4-5 level 2 || conducted/radiated emissions EN 55022 Class B || emission EN 50081-1″,”value”:”electrostatic discharges EN/IEC 61000-4-2 || emission EN 61000-6-3 || induced electromagnetic field EN/IEC 61000-4-6 level 3 || radiated electromagnetic field EN/IEC 61000-4-3 level 3 || rapid transient IEC 61000-4-4 level 3 || surge EN/IEC 61000-4-5 level 2 || conducted/radiated emissions EN 55022 Class B || emission EN 50081-1″},{“name”:”Output Protection Type”,”normalizedValue”:”against overload 1.3 x In || against short-circuits automatic reset || line protection 1 x 15 A integrated fuse per channel”,”value”:”against overload 1.3 x In || against short-circuits automatic reset || line protection 1 x 15 A integrated fuse per channel”},{“name”:”Product Or Component Type”,”normalizedValue”:”electronic protection module”,”value”:”electronic protection module”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-60 DegC”,”value”:”-25-60 DegC”},{“name”:”Local Signalling”,”normalizedValue”:”for channel status 1 LED per channel (green/red) || for channel status 1 relay”,”value”:”for channel status 1 LED per channel (green/red) || for channel status 1 relay”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 conforming to EN/IEC 60529″,”value”:”IP20 conforming to EN/IEC 60529″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Philippines”,”value”:”Philippines”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.