Description
[{“name”:”Item”,”normalizedValue”:”Electric Tankless Water Heater”,”rank”:1,”value”:”Electric Tankless Water Heater”},{“name”:”Item – Water Heaters”,”normalizedValue”:”Electric Tankless Water Heater”,”rank”:1,”value”:”Electric Tankless Water Heater”},{“name”:”Water Heater Design”,”normalizedValue”:”Point-of-Use”,”rank”:2,”value”:”Point-of-Use”},{“name”:”Water Heater Application”,”normalizedValue”:”Undersink”,”rank”:3,”value”:”Undersink”},{“name”:”Commercial / Residential”,”normalizedValue”:”Both”,”rank”:4,”value”:”Both”},{“name”:”Watts – Water Heaters”,”normalizedValue”:”3500″,”rank”:5,”value”:”3500″},{“name”:”Amps – Water Heaters”,”normalizedValue”:”29″,”rank”:6,”value”:”29″},{“name”:”Voltage – Water Heaters”,”normalizedValue”:”120″,”rank”:7,”value”:”120″},{“name”:”Min. Flow Activation”,”normalizedValue”:”0.3 gpm”,”rank”:8,”value”:”0.30 gpm”},{“name”:”Phase – Water Heaters”,”normalizedValue”:”1″,”rank”:9,”value”:”1″},{“name”:”Temp. Range – Water Heaters”,”normalizedValue”:”80 to 120 deg F”,”rank”:10,”value”:”80 Degrees to 120 Degrees F”},{“name”:”Max. Flow Rate”,”normalizedValue”:”0.6 gpm”,”value”:”0.6 gpm”},{“name”:”Default Temperature”,”normalizedValue”:”100 deg F”,”value”:”100 Degrees F”},{“name”:”Includes”,”normalizedValue”:”2 ft. Wire Harness, 3/8″ Hose Connector”,”value”:”2 ft. Wire Harness, 3/8″ Hose Connector”},{“name”:”Depth”,”normalizedValue”:”3-1/4 in”,”value”:”3-1/4″”},{“name”:”Standards”,”normalizedValue”:”ANSI/UL Standard 499″,”value”:”ANSI/UL Standard 499″},{“name”:”Mounting”,”normalizedValue”:”Wall”,”value”:”Wall”},{“name”:”Width”,”normalizedValue”:”7-1/2 in”,”value”:”7-1/2″”},{“name”:”Height”,”normalizedValue”:”6-1/2 in”,”value”:”6-1/2″”},{“name”:”Wire Size”,”normalizedValue”:”10 AWG”,”value”:”10 AWG”},{“name”:”Elements”,”normalizedValue”:”Bare Wire Nickel Chrome”,”value”:”Bare Wire Nickel Chrome”},{“name”:”Temp. Rise @ 0.5 GPM”,”normalizedValue”:”48 deg F”,”value”:”48 Degrees F”},{“name”:”Residential / Commercial”,”normalizedValue”:”Both”,”value”:”Both”},{“name”:”Features”,”normalizedValue”:”Compact Design, Reduce Energy Costs, Flow Switch Activation”,”value”:”Compact Design, Reduce Energy Costs, Flow Switch Activation”},{“name”:”Pressure Range”,”normalizedValue”:”30 to 150 psi”,”value”:”30 to 150 psi”},{“name”:”Water Connection”,”normalizedValue”:”3/8″ Compression”,”value”:”3/8″ Compression”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Overall Height”,”normalizedValue”:”6-1/2 in”,”value”:”6.5 in”},{“name”:”Overall Width”,”normalizedValue”:”7-1/2 in”,”value”:”7.5 in”},{“name”:”Overall Depth”,”normalizedValue”:”3-1/4 in”,”value”:”3.25 in”},{“name”:”Application”,”normalizedValue”:”Commercial Condominiums, Gas Stations, Hotels, Malls, Manufacturing Facilities, Motels, Office Buildings, Restaurants, Schools, Stores, Warehouses”,”value”:”Commercial Condominiums, Gas Stations, Hotels, Malls, Manufacturing Facilities, Motels, Office Buildings, Restaurants, Schools, Stores, Warehouses”},{“name”:”Minimum Delivered Temperature”,”normalizedValue”:”86 deg F”,”value”:”86 Degrees F”},{“name”:”Energy Factor”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”Temperature Range”,”normalizedValue”:”86 to 122 deg F”,”value”:”86 Degrees F to 122 Degrees F”},{“name”:”Hot Outlet Type”,”normalizedValue”:”Compression”,”value”:”Compression”},{“name”:”Maximum Delivered Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Current”,”normalizedValue”:”29 A”,”value”:”29 A”},{“name”:”Cord Conductor Gauge”,”normalizedValue”:”10/2 AWG Wire”,”value”:”10/2 AWG Wire”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”10 yr Against Leakage, 3 yr Against Defects in Workmanship and Materials”,”value”:”10 yr Against Leakage, 3 yr Against Defects in Workmanship and Materials”},{“name”:”Cold Inlet Size”,”normalizedValue”:”3/8 in”,”value”:”3/8 in”},{“name”:”Hot Outlet Size”,”normalizedValue”:”3/8 in”,”value”:”3/8 in”},{“name”:”Element Material”,”normalizedValue”:”Nichrome”,”value”:”Nichrome”},{“name”:”Power Consumption”,”normalizedValue”:”3,500 W”,”value”:”3,500 W”},{“name”:”Adjustable Thermostat”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Temperature Rise @ Flow”,”normalizedValue”:”48 Degrees F @ 0.5 gpm”,”value”:”48 Degrees F @ 0.5 gpm”},{“name”:”Operating Voltage”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Maximum Flow Rate”,”normalizedValue”:”0.5 gpm”,”value”:”0.5 gpm”},{“name”:”Mounting Type”,”normalizedValue”:”Wall Mounting”,”value”:”Wall Mounting”},{“name”:”Minimum Flow Activation”,”normalizedValue”:”0.3 gpm”,”value”:”0.3 gpm”},{“name”:”Minimum Water Pressure”,”normalizedValue”:”30 psi”,”value”:”30 psi”},{“name”:”Cold Inlet Type”,”normalizedValue”:”Compression”,”value”:”Compression”},{“name”:”Market”,”normalizedValue”:”Commercial, Industrial”,”value”:”Commercial, Industrial”},{“name”:”Maximum Water Pressure”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Overall Dimensions – H x W x D”,”normalizedValue”:”6-1/2 in x 7-1/2 in x 3-1/4 in”,”value”:”6.5 in x 7.5 in x 3.25 in”},{“name”:”Environment”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Germany”,”value”:”Germany”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.