Description
[{“name”:”Water Heater Design”,”normalizedValue”:”Point-of-Use”,”rank”:2,”value”:”Point-of-Use”},{“name”:”Voltage – Water Heaters”,”normalizedValue”:”240V/208V”,”rank”:4,”value”:”240V/208V”},{“name”:”Watts – Water Heaters”,”normalizedValue”:”6,000 W”,”rank”:5,”value”:”6,000 W”},{“name”:”Amps – Water Heaters”,”normalizedValue”:”25 A”,”rank”:6,”value”:”25 A”},{“name”:”Phase – Water Heaters”,”normalizedValue”:”1″,”rank”:9,”value”:”1″},{“name”:”Temp. Range – Water Heaters”,”normalizedValue”:”82 to 130 deg F”,”rank”:10,”value”:”82 Degrees to 130 Degrees F”},{“name”:”Min. Flow Activation”,”normalizedValue”:”0.48 gpm”,”rank”:11,”value”:”0.48 gpm”},{“name”:”Water Heater Application”,”normalizedValue”:”General Purpose”,”rank”:12,”value”:”General Purpose”},{“name”:”Commercial / Residential”,”normalizedValue”:”Commercial”,”rank”:13,”value”:”Commercial”},{“name”:”Item”,”normalizedValue”:”Electric Tankless Water Heater”,”rank”:15,”value”:”Electric Tankless Water Heater”},{“name”:”Item – Water Heaters”,”normalizedValue”:”Electric Tankless Water Heater”,”value”:”Electric Tankless Water Heaters”},{“name”:”Elements”,”normalizedValue”:”Copper-Clad”,”value”:”Copper-Clad”},{“name”:”Temp. Rise @ 2.5 GPM – Water Heaters”,”normalizedValue”:”12 deg F”,”value”:”12 Degrees F”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Temp. Rise @ 1.5 GPM”,”normalizedValue”:”28 deg F”,”value”:”28 Degrees F”},{“name”:”Width”,”normalizedValue”:”7-15/16 in”,”value”:”7 15/16 in”},{“name”:”Overall Height”,”normalizedValue”:”14.19 in”,”value”:”14.19 in”},{“name”:”Temp. Rise @ 6.0 GPM”,”normalizedValue”:”7 deg F”,”value”:”7 Degrees F”},{“name”:”Temp. Rise @ 4.0 GPM”,”normalizedValue”:”8 deg F”,”value”:”8 Degrees F”},{“name”:”Temp. Rise @ 0.5 GPM”,”normalizedValue”:”82 deg F”,”value”:”82 Degrees F”},{“name”:”Depth”,”normalizedValue”:”3-7/8 in”,”value”:”3 7/8 in”},{“name”:”Features”,”normalizedValue”:”Cold Water Only Line Needed to Be Run to Lavatory, Compatible with Sensor Actuated or Metered Faucets, Prevents Dry Firing, Flow Switch for Virtually Silent Operation, High Limit Switch with Manual Reset”,”value”:”Cold Water Only Line Needed to Be Run to Lavatory, Compatible with Sensor Actuated or Metered Faucets, Prevents Dry Firing, Flow Switch for Virtually Silent Operation, High Limit Switch with Manual Reset”},{“name”:”Wire Size”,”normalizedValue”:”10/2 AWG”,”value”:”10/2 AWG”},{“name”:”Standards”,”normalizedValue”:”499 and Conform to CAN/CSA E335-1/3E and E335-2-35, ANSI ANSI/UL Standard”,”value”:”499 and Conform to CAN/CSA E335-1/3E and E335-2-35, ANSI ANSI/UL Standard”},{“name”:”Overall Depth”,”normalizedValue”:”3.88 in”,”value”:”3.88 in”},{“name”:”Height”,”normalizedValue”:”14-3/16 in”,”value”:”14 3/16 in”},{“name”:”Water Connection”,”normalizedValue”:”1/2 in NPT”,”value”:”1/2 in NPT”},{“name”:”Overall Width”,”normalizedValue”:”7.94 in”,”value”:”7.94 in”},{“name”:”Thermal Efficiency”,”normalizedValue”:”99 %”,”value”:”99 %”},{“name”:”Element Material”,”normalizedValue”:”Copper-Clad”,”value”:”Copper-Clad”},{“name”:”Current”,”normalizedValue”:”25 A”,”value”:”25 A”},{“name”:”Minimum Delivered Temperature”,”normalizedValue”:”82 deg F”,”value”:”82 Degrees F”},{“name”:”Temperature Rise @ Flow”,”normalizedValue”:”20 to 15 Degrees F @ 2 gpm, 28 to 20 Degrees F @ 1.50 gpm, 41 to 31 Degrees F @ 1 gpm, 54 to 41 Degrees F @ 0.75 gpm, 82 to 61 Degrees F @ 0.50 gpm”,”value”:”20 to 15 Degrees F @ 2 gpm, 28 to 20 Degrees F @ 1.50 gpm, 41 to 31 Degrees F @ 1 gpm, 54 to 41 Degrees F @ 0.75 gpm, 82 to 61 Degrees F @ 0.50 gpm”},{“name”:”Power Consumption”,”normalizedValue”:”6,000 W”,”value”:”6,000 W”},{“name”:”Application”,”normalizedValue”:”Commercial Condominiums, Gas Stations, Hotels, Malls, Manufacturing Facilities, Motels, Office Buildings, Restaurants, Schools, Stores, Warehouses”,”value”:”Commercial Condominiums, Gas Stations, Hotels, Malls, Manufacturing Facilities, Motels, Office Buildings, Restaurants, Schools, Stores, Warehouses”},{“name”:”Cold Inlet Gender”,”normalizedValue”:”Female”,”value”:”Female”},{“name”:”Cold Inlet Size”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”3 yr Parts Warranty, 7 yr Leakage”,”value”:”3 yr Parts Warranty, 7 yr Leakage”},{“name”:”Cord Conductor Gauge”,”normalizedValue”:”10/2 AWG Wire”,”value”:”10/2 AWG Wire”},{“name”:”Operating Voltage”,”normalizedValue”:”240/208V AC”,”value”:”240/208V AC”},{“name”:”Housing Material”,”normalizedValue”:”Copper”,”value”:”Copper”},{“name”:”Maximum Water Pressure”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Environment”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Maximum Flow Rate”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Adjustable Thermostat”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Flow Activation”,”normalizedValue”:”0.48 gpm”,”value”:”0.48 gpm”},{“name”:”Hot Outlet Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Hot Outlet Size”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Cold Inlet Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Mounting Type”,”normalizedValue”:”Wall Mounting”,”value”:”Wall Mounting”},{“name”:”Minimum Water Pressure”,”normalizedValue”:”30 psi”,”value”:”30 psi”},{“name”:”Hot Outlet Connection Gender”,”normalizedValue”:”Female”,”value”:”Female”},{“name”:”Maximum Delivered Temperature”,”normalizedValue”:”130 deg F”,”value”:”130 Degrees F”},{“name”:”Market”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Germany”,”value”:”Germany”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.