Description
[{“name”:”Item”,”normalizedValue”:”Draft Inducer”,”rank”:2,”value”:”Draft Inducer”},{“name”:”Type”,”normalizedValue”:”In-line”,”rank”:3,”value”:”In-line”},{“name”:”Voltage”,”normalizedValue”:”115 V”,”rank”:4,”value”:”115″},{“name”:”Depth (In.)”,”normalizedValue”:”5-7/8″,”rank”:5,”value”:”5 7/8 in”},{“name”:”Cut Out Required”,”normalizedValue”:”2-5/8 x 7-1/8″,”rank”:6,”value”:”2-5/8 x 7-1/8″},{“name”:”HP”,”normalizedValue”:”1/70 hp”,”rank”:7,”value”:”1/70 hp”},{“name”:”Construction Material”,”normalizedValue”:”Aluminized Steel Housing and Blower Wheel”,”rank”:8,”value”:”Aluminized Steel Housing and Blower Wheel”},{“name”:”Amps”,”normalizedValue”:”0.43″,”rank”:9,”value”:”0.43″},{“name”:”Remarks”,”normalizedValue”:”View Catalog Page for Selection Criteria”,”rank”:11,”value”:”View Catalog Page for Selection Criteria”},{“name”:”Height (In.)”,”normalizedValue”:”7-5/8″,”rank”:12,”value”:”7 5/8 in”},{“name”:”Vent Pipe Dia. (In.)”,”normalizedValue”:”3 to 6″,”rank”:13,”value”:”3 to 6″},{“name”:”Width (In.)”,”normalizedValue”:”9″,”rank”:18,”value”:”9 in”},{“name”:”Application”,”normalizedValue”:”Furnaces, Water Heaters, Boilers”,”rank”:19,”value”:”Boilers, Furnaces, Water Heaters”},{“name”:”Watts”,”normalizedValue”:”35″,”rank”:20,”value”:”35 W”},{“name”:”Heater Btu Input @ 270 (F)”,”normalizedValue”:”69,000 105,000 111,000 100,000″,”value”:”69,000 105,000 111,000 100,000″},{“name”:”BtuH Input”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 0.000-In. SP”,”normalizedValue”:””,”value”:”N/A”},{“name”:”CFM @ 270 Deg. (F)”,”normalizedValue”:”48,727,268″,”value”:”48727268″},{“name”:”CFM @ 530 Deg. (F)”,”normalizedValue”:”33,483,913″,”value”:”33483913″},{“name”:”CFM @ 0.700-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 1.40-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Heater Btu Input @ 390 (F)”,”normalizedValue”:”72,000 109,000 104,000 34,000″,”value”:”72,000 109,000 104,000 34,000″},{“name”:”SP @ 270 Deg. (F)”,”normalizedValue”:”0.0340.0420.0430.041″,”value”:”0.0340.0420.0430.041″},{“name”:”Duct Temp. Deg. (F)”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 390 Deg. (F)”,”normalizedValue”:”36,555,217″,”value”:”36555217″},{“name”:”Heater Btu Input @ 530 (F)”,”normalizedValue”:”58,000 92,000 74,000 25,000″,”value”:”58,000 92,000 74,000 25,000″},{“name”:”SP @ 530 Deg. (F)”,”normalizedValue”:”0.0480.0570.0520.035″,”value”:”0.0480.0570.0520.035″},{“name”:”CFM @ 0.500-In. SP”,”normalizedValue”:”N/A.”,”value”:”N/A.”},{“name”:”CFM @ 1.000-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”SP @ 390 Deg. (F)”,”normalizedValue”:”0.0470.0530.0520.042″,”value”:”0.0470.0530.0520.042″},{“name”:”Overall Height”,”normalizedValue”:”8-3/4 in”,”value”:”8 3/4 in”},{“name”:”Overall Width”,”normalizedValue”:”8 in”,”value”:”8 in”},{“name”:”Minimum Vent Pipe Diameter”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Maximum Vent Pipe Diameter”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Current”,”normalizedValue”:”0.43 A”,”value”:”0.43 A”},{“name”:”Maximum Motor Horsepower”,”normalizedValue”:”1/70 hp”,”value”:”1/70 hp”},{“name”:”Nameplate Voltage”,”normalizedValue”:”115V AC”,”value”:”115V AC”},{“name”:”Minimum Heat Input”,”normalizedValue”:”25,000 Btu (Oil/Barometric), 34,000 Btu (Gas/Barometric), 69,000 Btu (Gas/Draft Hood)”,”value”:”25,000 Btu (Oil/Barometric), 34,000 Btu (Gas/Barometric), 69,000 Btu (Gas/Draft Hood)”},{“name”:”Maximum Heat Input”,”normalizedValue”:”109,000 Btu (Gas/Barometric), 111,000 Btu (Gas/Draft Hood), 92,000 Btu (Oil/Barometric)”,”value”:”109,000 Btu (Gas/Barometric), 111,000 Btu (Gas/Draft Hood), 92,000 Btu (Oil/Barometric)”},{“name”:”Maximum Heater BTU Input for Oil Appliance”,”normalizedValue”:”300,000 BtuH”,”value”:”300,000 BtuH”},{“name”:”Power Consumption”,”normalizedValue”:”34 W”,”value”:”34 W”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Overall Depth”,”normalizedValue”:”8-7/8 in”,”value”:”8 7/8 in”},{“name”:”Cutout Size”,”normalizedValue”:”2 5/8 in x 7 1/8 in”,”value”:”2 5/8 in x 7 1/8 in”},{“name”:”Maximum Heater BTU Input for Gas Appliance”,”normalizedValue”:”377,000 BtuH”,”value”:”377,000 BtuH”},{“name”:”For Fuel Type”,”normalizedValue”:”Natural Gas, Oil, Coal”,”value”:”Coal, Natural Gas, Oil”},{“name”:”For Appliance Type”,”normalizedValue”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”,”value”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”},{“name”:”Maximum Static Pressure”,”normalizedValue”:”0 in wc”,”value”:”0 in wc”},{“name”:”Airflow at Temperature”,”normalizedValue”:”33 cfm @ 530 Degrees F, 48 cfm @ 530 Degrees F, 39 cfm @ 530 Degrees F, 13 cfm @ 530 Degrees F, 36 cfm @ 390 Degrees F, 55 cfm @ 390 Degrees F, 52 cfm @ 390 Degrees F, 17 cfm @ 390 Degrees F, 48 cfm @ 270 Degrees F, 72 cfm @ 270 Degrees F, 72 cfm @ 270 Degrees F, 68 cfm @ 270 Degrees F”,”value”:”33 cfm @ 530 Degrees F, 48 cfm @ 530 Degrees F, 39 cfm @ 530 Degrees F, 13 cfm @ 530 Degrees F, 36 cfm @ 390 Degrees F, 55 cfm @ 390 Degrees F, 52 cfm @ 390 Degrees F, 17 cfm @ 390 Degrees F, 48 cfm @ 270 Degrees F, 72 cfm @ 270 Degrees F, 72 cfm @ 270 Degrees F, 68 cfm @ 270 Degrees F”},{“name”:”Blower Type”,”normalizedValue”:”Induced Draft Blower”,”value”:”Induced Draft Blower”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.