Description
[{“name”:”Item”,”normalizedValue”:”Draft Inducer”,”rank”:2,”value”:”Draft Inducer”},{“name”:”Type”,”normalizedValue”:”In-line”,”rank”:3,”value”:”In-line”},{“name”:”Voltage”,”normalizedValue”:”115 V”,”rank”:4,”value”:”115″},{“name”:”Depth (In.)”,”normalizedValue”:”7″,”rank”:5,”value”:”7 in”},{“name”:”Cut Out Required”,”normalizedValue”:”3-1/8 x 8-5/8″,”rank”:6,”value”:”3-1/8 x 8-5/8″},{“name”:”HP”,”normalizedValue”:”1/20 HP”,”rank”:7,”value”:”1/20 hp”},{“name”:”Construction Material”,”normalizedValue”:”Aluminized Steel Housing and Blower Wheel”,”rank”:8,”value”:”Aluminized Steel Housing and Blower Wheel”},{“name”:”Amps”,”normalizedValue”:”0.96″,”rank”:9,”value”:”0.96″},{“name”:”Remarks”,”normalizedValue”:”View Catalog Page for Selection Criteria”,”rank”:11,”value”:”View Catalog Page for Selection Criteria”},{“name”:”Height (In.)”,”normalizedValue”:”9-1/8″,”rank”:12,”value”:”9 1/8 in”},{“name”:”Vent Pipe Dia. (In.)”,”normalizedValue”:”5 to 8″,”rank”:13,”value”:”5 to 8″},{“name”:”Width (In.)”,”normalizedValue”:”9-1/2″,”rank”:18,”value”:”9 1/2 in”},{“name”:”Application”,”normalizedValue”:”Furnaces, Water Heaters, Boilers”,”rank”:19,”value”:”Boilers, Furnaces, Water Heaters”},{“name”:”Watts”,”normalizedValue”:”74″,”rank”:20,”value”:”74 W”},{“name”:”SP @ 390 Deg. (F)”,”normalizedValue”:”0.0850.0900.0850.075″,”value”:”0.0850.0900.0850.075″},{“name”:”CFM @ 1.000-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”SP @ 270 Deg. (F)”,”normalizedValue”:”0.0630.0730.0750.068″,”value”:”0.0630.0730.0750.068″},{“name”:”Heater Btu Input @ 390 (F)”,”normalizedValue”:”330,000 377,000 330,000 222,000″,”value”:”330,000 377,000 330,000 222,000″},{“name”:”Heater Btu Input @ 530 (F)”,”normalizedValue”:”295,000 300,000 230,000 123,000″,”value”:”295,000 300,000 230,000 123,000″},{“name”:”CFM @ 270 Deg. (F)”,”normalizedValue”:”190,246,259,217″,”value”:”190246259217″},{“name”:”Heater Btu Input @ 270 (F)”,”normalizedValue”:”270,000 356,000 360,000 320,000″,”value”:”270,000 356,000 360,000 320,000″},{“name”:”BtuH Input”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 0.000-In. SP”,”normalizedValue”:””,”value”:”N/A”},{“name”:”CFM @ 1.40-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 0.700-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 390 Deg. (F)”,”normalizedValue”:”166,190,166,110″,”value”:”166190166110″},{“name”:”SP @ 530 Deg. (F)”,”normalizedValue”:”0.0920.0930.0800.065″,”value”:”0.0920.0930.0800.065″},{“name”:”Duct Temp. Deg. (F)”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 530 Deg. (F)”,”normalizedValue”:”16,316,911,865″,”value”:”16316911865″},{“name”:”CFM @ 0.500-In. SP”,”normalizedValue”:”N/A.”,”value”:”N/A.”},{“name”:”Overall Width”,”normalizedValue”:”9-1/2 in”,”value”:”9 1/2 in”},{“name”:”Overall Height”,”normalizedValue”:”9-1/2 in”,”value”:”9 1/2 in”},{“name”:”Nameplate Voltage”,”normalizedValue”:”115V AC”,”value”:”115V AC”},{“name”:”Maximum Vent Pipe Diameter”,”normalizedValue”:”8 in”,”value”:”8 in”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Cutout Size”,”normalizedValue”:”3 1/8 in x 8 5/8 in”,”value”:”3 1/8 in x 8 5/8 in”},{“name”:”For Appliance Type”,”normalizedValue”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”,”value”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”},{“name”:”Maximum Heater BTU Input for Oil Appliance”,”normalizedValue”:”92,000 BtuH”,”value”:”92,000 BtuH”},{“name”:”For Fuel Type”,”normalizedValue”:”Natural Gas, Oil”,”value”:”Natural Gas, Oil”},{“name”:”Power Consumption”,”normalizedValue”:”74 W”,”value”:”74 W”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Maximum Heat Input”,”normalizedValue”:”300,000 Btu (Oil/Barometric), 360,000 Btu (Gas/Draft Hood), 377,000 Btu (Gas/Barometric)”,”value”:”300,000 Btu (Oil/Barometric), 360,000 Btu (Gas/Draft Hood), 377,000 Btu (Gas/Barometric)”},{“name”:”Maximum Heater BTU Input for Gas Appliance”,”normalizedValue”:”111,000 BtuH”,”value”:”111,000 BtuH”},{“name”:”Maximum Static Pressure”,”normalizedValue”:”0 in wc”,”value”:”0 in wc”},{“name”:”Overall Depth”,”normalizedValue”:”8-7/8 in”,”value”:”8 7/8 in”},{“name”:”Maximum Motor Horsepower”,”normalizedValue”:”1/20 hp”,”value”:”1/20 hp”},{“name”:”Airflow at Temperature”,”normalizedValue”:”163 cfm @ 530 Degrees F, 169 cfm @ 530 Degrees F, 118 cfm @ 530 Degrees F, 65 cfm @ 530 Degrees F, 166 cfm @ 390 Degrees F, 190 cfm @ 390 Degrees F, 166 cfm @ 390 Degrees F, 110 cfm @ 390 Degrees F, 190 cfm @ 270 Degrees F, 246 cfm @ 270 Degrees F, 259 cfm @ 270 Degrees F, 217 cfm @ 270 Degrees F”,”value”:”163 cfm @ 530 Degrees F, 169 cfm @ 530 Degrees F, 118 cfm @ 530 Degrees F, 65 cfm @ 530 Degrees F, 166 cfm @ 390 Degrees F, 190 cfm @ 390 Degrees F, 166 cfm @ 390 Degrees F, 110 cfm @ 390 Degrees F, 190 cfm @ 270 Degrees F, 246 cfm @ 270 Degrees F, 259 cfm @ 270 Degrees F, 217 cfm @ 270 Degrees F”},{“name”:”Current”,”normalizedValue”:”0.96 A”,”value”:”0.96 A”},{“name”:”Minimum Vent Pipe Diameter”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Minimum Heat Input”,”normalizedValue”:”123,000 Btu (Oil/Barometric), 222,000 Btu (Gas/Barometric), 270,000 Btu (Gas/Draft Hood)”,”value”:”123,000 Btu (Oil/Barometric), 222,000 Btu (Gas/Barometric), 270,000 Btu (Gas/Draft Hood)”},{“name”:”Blower Type”,”normalizedValue”:”Induced Draft Blower”,”value”:”Induced Draft Blower”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.