Draft Inducer, 115, Aluminized Steel Housing and Blower Wheel, 14 3/4 in W, 17 in H

$772,99

Draft Inducer, Application Boilers, Furnaces, Water Heaters, For Fuel Type Natural Gas, Oil, For Appliance Type Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters, Maximum Vent Pipe Diameter 18 in, Minimum Vent Pipe Diameter 9 in, Maximum Heater BTU Input for Gas Appliance 2,460,000 BtuH, Maximum Heater BTU Input for Oil Appliance 1,900,000 BtuH, Nameplate Voltage 115V AC, Current 5.4 A, Frequency 60 Hz, Maximum Static Pressure 1/8 in wc

9999 in stock

SKU: GRG3403723 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Draft Inducer”,”rank”:2,”value”:”Draft Inducer”},{“name”:”Type”,”normalizedValue”:”In-line”,”rank”:3,”value”:”In-line”},{“name”:”Voltage”,”normalizedValue”:”115 V”,”rank”:4,”value”:”115″},{“name”:”Depth (In.)”,”normalizedValue”:”10″,”rank”:5,”value”:”10 in”},{“name”:”Cut Out Required”,”normalizedValue”:”4-1/4 x 14-3/4″,”rank”:6,”value”:”4-1/4 x 14-3/4″},{“name”:”HP”,”normalizedValue”:”1/4 hp”,”rank”:7,”value”:”1/4 hp”},{“name”:”Construction Material”,”normalizedValue”:”Aluminized Steel Housing and Blower Wheel”,”rank”:8,”value”:”Aluminized Steel Housing and Blower Wheel”},{“name”:”Amps”,”normalizedValue”:”5.4″,”rank”:9,”value”:”5.4″},{“name”:”Includes”,”normalizedValue”:”Fastening Band”,”rank”:10,”value”:”Fastening Band”},{“name”:”Remarks”,”normalizedValue”:”View Catalog Page for Selection Criteria”,”rank”:11,”value”:”View Catalog Page for Selection Criteria”},{“name”:”Height (In.)”,”normalizedValue”:”17″,”rank”:12,”value”:”17 in”},{“name”:”Vent Pipe Dia. (In.)”,”normalizedValue”:”9 to 18″,”rank”:13,”value”:”9 to 18″},{“name”:”Width (In.)”,”normalizedValue”:”14-3/4″,”rank”:18,”value”:”14 3/4 in”},{“name”:”Application”,”normalizedValue”:”Furnaces, Water Heaters, Boilers”,”rank”:19,”value”:”Boilers, Furnaces, Water Heaters”},{“name”:”Heater Btu Input @ 270 (F)”,”normalizedValue”:”1,460,000 2,080,000 1,920,000 1,840,000 900,000 650,000″,”value”:”1,460,000 2,080,000 1,920,000 1,840,000 900,000 650,000″},{“name”:”Heater Btu Input @ 530 (F)”,”normalizedValue”:”1,700,000 1,900,000 1,500,000 825,000 350,000 200,000″,”value”:”1,700,000 1,900,000 1,500,000 825,000 350,000 200,000″},{“name”:”Duct Temp. Deg. (F)”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 0.700-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”BtuH Input”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 530 Deg. (F)”,”normalizedValue”:”9,001,010,789,453,184,000″,”value”:”9001010789453184106″},{“name”:”CFM @ 1.40-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”SP @ 390 Deg. (F)”,”normalizedValue”:”0.1750.1850.1820.1580.1130.095″,”value”:”0.1750.1850.1820.1580.1130.095″},{“name”:”Heater Btu Input @ 390 (F)”,”normalizedValue”:”1,970,000 2,460,000 2,230,000 1,470,000 650,000 440,000″,”value”:”1,970,000 2,460,000 2,230,000 1,470,000 650,000 440,000″},{“name”:”SP @ 270 Deg. (F)”,”normalizedValue”:”0.1450.1700.1600.1590.1200.099″,”value”:”0.1450.1700.1600.1590.1200.099″},{“name”:”CFM @ 270 Deg. (F)”,”normalizedValue”:”1,010,137,013,251,270,639,616″,”value”:”1010137013251270620450″},{“name”:”CFM @ 390 Deg. (F)”,”normalizedValue”:”98,912,401,120,740,343,808″,”value”:”98912401120740340220″},{“name”:”CFM @ 1.000-In. SP”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”CFM @ 0.000-In. SP”,”normalizedValue”:””,”value”:”N/A”},{“name”:”CFM @ 0.500-In. SP”,”normalizedValue”:”N/A.”,”value”:”N/A.”},{“name”:”SP @ 530 Deg. (F)”,”normalizedValue”:”0.1800.1800.1700.1350.0950.075″,”value”:”0.1800.1800.1700.1350.0950.075″},{“name”:”Overall Height”,”normalizedValue”:”17 in”,”value”:”17 in”},{“name”:”Overall Width”,”normalizedValue”:”14-3/4 in”,”value”:”14 3/4 in”},{“name”:”Maximum Static Pressure”,”normalizedValue”:”0.125 in wc”,”value”:”1/8 in wc”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Power Consumption”,”normalizedValue”:”0.2 HP”,”value”:”0.2 hp”},{“name”:”Maximum Heater BTU Input for Oil Appliance”,”normalizedValue”:”1,900,000 BtuH”,”value”:”1,900,000 BtuH”},{“name”:”Maximum Heater BTU Input for Gas Appliance”,”normalizedValue”:”2,460,000 BtuH”,”value”:”2,460,000 BtuH”},{“name”:”Current”,”normalizedValue”:”5.4 A”,”value”:”5.4 A”},{“name”:”Maximum Heat Input”,”normalizedValue”:”1,900,000 Btu (Oil/Barometric), 2,080,000 Btu (Gas/Draft Hood), 2,460,000 Btu (Gas/Barometric)”,”value”:”1,900,000 Btu (Oil/Barometric), 2,080,000 Btu (Gas/Draft Hood), 2,460,000 Btu (Gas/Barometric)”},{“name”:”For Appliance Type”,”normalizedValue”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”,”value”:”Boilers, Furnaces, Non-Condensing Chimney Vented Gas and Oil Fueled Heating Equipment, Ovens, Water Heaters”},{“name”:”For Fuel Type”,”normalizedValue”:”Natural Gas, Oil”,”value”:”Natural Gas, Oil”},{“name”:”Overall Depth”,”normalizedValue”:”13 in”,”value”:”13 in”},{“name”:”Nameplate Voltage”,”normalizedValue”:”115V AC”,”value”:”115V AC”},{“name”:”Airflow at Temperature”,”normalizedValue”:”1010 cfm @ 270 Degrees F, 1370 cfm @ 270 Degrees F, 1325 cfm @ 270 Degrees F, 1270 cfm @ 270 Degrees F, 620 cfm @ 270 Degrees F, 450 cfm @ 270 Degrees F, 900 cfm @ 530 Degrees F, 1010 cfm @ 530 Degrees F, 789 cfm @ 530 Degrees F, 453 cfm @ 530 Degrees F, 184 cfm @ 530 Degrees F, 106 cfm @ 530 Degrees F, 989 cfm @ 390 Degrees F, 1240 cfm @ 390 Degrees F, 1120 cfm @ 390 Degrees F, 740 cfm @ 390 Degrees F, 340 cfm @ 390 Degrees F, 220 cfm @ 390 Degrees F”,”value”:”1010 cfm @ 270 Degrees F, 1370 cfm @ 270 Degrees F, 1325 cfm @ 270 Degrees F, 1270 cfm @ 270 Degrees F, 620 cfm @ 270 Degrees F, 450 cfm @ 270 Degrees F, 900 cfm @ 530 Degrees F, 1010 cfm @ 530 Degrees F, 789 cfm @ 530 Degrees F, 453 cfm @ 530 Degrees F, 184 cfm @ 530 Degrees F, 106 cfm @ 530 Degrees F, 989 cfm @ 390 Degrees F, 1240 cfm @ 390 Degrees F, 1120 cfm @ 390 Degrees F, 740 cfm @ 390 Degrees F, 340 cfm @ 390 Degrees F, 220 cfm @ 390 Degrees F”},{“name”:”Cutout Size”,”normalizedValue”:”4 1/4 in x 14 3/4 in”,”value”:”4 1/4 in x 14 3/4 in”},{“name”:”Maximum Vent Pipe Diameter”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Minimum Heat Input”,”normalizedValue”:”200,000 Btu (Oil/Barometric), 440,000 Btu (Gas/Barometric), 650,000 Btu (Gas/Draft Hood)”,”value”:”200,000 Btu (Oil/Barometric), 440,000 Btu (Gas/Barometric), 650,000 Btu (Gas/Draft Hood)”},{“name”:”Minimum Vent Pipe Diameter”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”Blower Type”,”normalizedValue”:”Induced Draft Blower”,”value”:”Induced Draft Blower”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Draft Inducer, 115, Aluminized Steel Housing and Blower Wheel, 14 3/4 in W, 17 in H”