Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Multimeter”,”rank”:1,”value”:”Digital Multimeter”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”rank”:2,”value”:”LCD”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”rank”:3,”value”:”Yes”},{“name”:”Instrument Counts”,”normalizedValue”:”4,000″,”rank”:4,”value”:”4,000″},{“name”:”Includes”,”normalizedValue”:”9V Battery, Adjustable Tilt Stand, Protective Holster, Test Leads, Type K Temperature Probe, Velcro Hanging Strap”,”rank”:5,”value”:”9V Battery, Adjustable Tilt Stand, Protective Holster, Test Leads, Type K Temperature Probe, Velcro Hanging Strap”},{“name”:”Standards”,”normalizedValue”:”CE”,”rank”:6,”value”:”CE”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”rank”:7,”value”:”Yes”},{“name”:”Data Logging”,”normalizedValue”:”No”,”rank”:8,”value”:”No”},{“name”:”Audible Continuity”,”normalizedValue”:”No”,”rank”:9,”value”:”No”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”rank”:10,”value”:”Yes”},{“name”:”Peak Hold”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Temp. Range”,”normalizedValue”:”-4 to 1,382 deg F”,”value”:”-4 Degrees to 1382 Degrees F”},{“name”:”Duty Cycle”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NIST Certification By”,”normalizedValue”:”Not Certified”,”value”:”Not Certified”},{“name”:”Max. Ohms”,”normalizedValue”:”40 megohm”,”value”:”40 megohm”},{“name”:”Max. DC Amps”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Interface”,”normalizedValue”:””,”value”:”None”},{“name”:”Instrument Safety Rating”,”normalizedValue”:”CAT III 600V”,”value”:”CAT III 600V”},{“name”:”Capacitance Range”,”normalizedValue”:”0.01 nF to 100 uF”,”value”:”0.01 nF to 100 uF”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Display”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Instrument Frequency Counter Range”,”normalizedValue”:”0.001 Hz to 10 MHz”,”value”:”0.001 Hz to 10 MHz”},{“name”:”Series”,”normalizedValue”:”EXTECH(R) EX400A”,”value”:”EXTECH(R) EX400A”},{“name”:”Max. AC Amps”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Basic DC Accuracy”,”normalizedValue”:”+/-0.30%”,”value”:”+/-0.30%”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Battery Chemistry”,”normalizedValue”:”Alkaline”,”value”:”Alkaline”},{“name”:”Minimum/Maximum Memory”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”41 deg F”,”value”:”41 Degrees F”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”0.1 uA”,”value”:”0.1 uA”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-1.50%”,”value”:”+/-1.50%”},{“name”:”Minimum DC Current Measurement”,”normalizedValue”:”0.1 uA”,”value”:”0.1 uA”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Overall Height”,”normalizedValue”:”7.4 in”,”value”:”7.4 in”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”0.1 uA”,”value”:”0.1 uA”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”100 uF”,”value”:”100 uF”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-3%”,”value”:”+/-3%”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NIST Certification By Manufacturer”,”normalizedValue”:”FLIR”,”value”:”FLIR”},{“name”:”Computer Interface Connection Type”,”normalizedValue”:””,”value”:”None”},{“name”:”Bar Graph Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.001 Hz”,”value”:”0.001 Hz”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”0.1 V”,”value”:”0.1 V”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”40 megaohm”,”value”:”40 megaohm”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”0.1 uA”,”value”:”0.1 uA”},{“name”:”Overall Width”,”normalizedValue”:”3.2 in”,”value”:”3.2 in”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-1.8%”,”value”:”+/-1.8%”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-3%”,”value”:”+/-3%”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K)”,”value”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K)”},{“name”:”Capacitance Measurement Resolution”,”normalizedValue”:”0.01 nF”,”value”:”0.01 nF”},{“name”:”Depth”,”normalizedValue”:”2 in”,”value”:”2 in”},{“name”:”Software Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”0.1 V”,”value”:”0.1 V”},{“name”:”Battery Size”,”normalizedValue”:”9V”,”value”:”9V”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:”0.1 ohm”,”value”:”0.1 ohm”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”True RMS Bandwidth”,”normalizedValue”:”1 kHz”,”value”:”1 kHz”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-0.30%”,”value”:”+/-0.30%”},{“name”:”Temperature Measurement Accuracy”,”normalizedValue”:”+/-3%”,”value”:”+/-3.00%”},{“name”:”Pulse Width”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Resistance Measurement”,”normalizedValue”:”0.1 ohm”,”value”:”0.1 ohm”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”10 MHz”,”value”:”10 MHz”},{“name”:”Battery Voltage”,”normalizedValue”:”9 V”,”value”:”9V”},{“name”:”Minimum Capacitance Measurement”,”normalizedValue”:”0.01 nF”,”value”:”0.01 nF”},{“name”:”Temperature Measurement Resolution”,”normalizedValue”:”1 deg F”,”value”:”1 Degrees F”},{“name”:”Minimum DC Voltage Measurement”,”normalizedValue”:”0.1 V”,”value”:”0.1 V”},{“name”:”Maximum Temperature Measurement”,”normalizedValue”:”1,382 deg F”,”value”:”1,382 Degrees F”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”+/-1.5%”,”value”:”+/-1.5%”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Weight”,”normalizedValue”:”0.75 lb”,”value”:”0.75 lb”},{“name”:”Minimum Temperature Measurement”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”0.1 V”,”value”:”0.1 V”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-1%”,”value”:”+/-1%”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”0.001 Hz”,”value”:”0.001 Hz”},{“name”:”Fuse Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.