Digital Clamp Meter, LCD, 600 A, 1.0 in (25 mm) Jaw Capacity, CAT III 600V Safety Rating

$177,99

Digital Clamp Meter, Audible Continuity Yes, Safety Rating CAT III 600V, AC Response Calculation TRMS, Maximum AC Current Measurement 600 A, Maximum AC Voltage Measurement 600 V, Maximum DC Current Measurement Not Applicable, Maximum DC Voltage Measurement 600 V, Current Leakage Testing No, Parameters Measured AC Current, AC Voltage, Capacitance, Continuity, DC Voltage, Frequency, Resistance, Intrinsically Safe No, Dustproof No, Waterproof No, Data Logging Yes, Thermal Imaging No

9999 in stock

SKU: GRG2943263 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”600″,”rank”:4,”value”:”600″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”600 V”,”rank”:7,”value”:”600 V”},{“name”:”Max. Ohms”,”normalizedValue”:”40,000,000″,”rank”:8,”value”:”40 megaohm”},{“name”:”Jaw Capacity”,”normalizedValue”:”1 in”,”rank”:9,”value”:”1.0 in (25 mm)”},{“name”:”Safety Rating”,”normalizedValue”:”CAT III 600V”,”rank”:11,”value”:”CAT III 600V”},{“name”:”Display”,”normalizedValue”:”LCD”,”rank”:13,”value”:”LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”0.4 in”,”rank”:14,”value”:”0.4 in”},{“name”:”Max. AC Volts”,”normalizedValue”:”600 V”,”rank”:16,”value”:”600 V”},{“name”:”Calibration Frequency”,”normalizedValue”:”50 to 500 Hz”,”rank”:19,”value”:”50 to 500 Hz”},{“name”:”Capacitance”,”normalizedValue”:”3,000 uF”,”value”:”3,000 uF”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Battery Type”,”normalizedValue”:”CR2032″,”value”:”CR2032″},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Peak Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Counter”,”normalizedValue”:”10 Hz to100 kHz with Test Leads; 40 Hz to 400 Hz with Jaw”,”value”:”10 Hz to100 kHz with Test Leads; 40 Hz to 400 Hz with Jaw”},{“name”:”Operating Temp.”,”normalizedValue”:”32 to 104 deg F”,”value”:”32 Degrees to 104 Degrees F”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0% + 5 Digits”,”value”:”+/-2.0% + 5 Digits”},{“name”:”Counts”,”normalizedValue”:”4,000″,”value”:”4,000″},{“name”:”Special Features”,”normalizedValue”:”Features Continuity Beeper to Quickly Find Opens and Shorts, Measures Frequency, Resistance and Capacitance, Residential/Commercial and Small Industrial Applications, Rubber Over-Molded Case Absorbs Shock”,”value”:”Features Continuity Beeper to Quickly Find Opens and Shorts, Measures Frequency, Resistance and Capacitance, Residential/Commercial and Small Industrial Applications, Rubber Over-Molded Case Absorbs Shock”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Includes”,”normalizedValue”:”Manual, Soft Carrying Pouch, Test Leads”,”value”:”Manual, Soft Carrying Pouch, Test Leads”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”40 Hz”,”value”:”40 Hz”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”1.0 in (25mm)”,”value”:”1.0 in (25mm)”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”87 deg F”,”value”:”87 Degrees F”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Minimum DC Voltage Measurement”,”normalizedValue”:”400 mV”,”value”:”400 mV”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/- 0.5%+4 digits”,”value”:”+/- 0.5%+4 digits”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, Continuity, DC Voltage, Frequency, Resistance”,”value”:”AC Current, AC Voltage, Capacitance, Continuity, DC Voltage, Frequency, Resistance”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/- 1.5% + 8 digits”,”value”:”+/- 1.5% + 8 digits”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Battery Size”,”normalizedValue”:”CR2032″,”value”:”CR2032″},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Instrument Counts”,”normalizedValue”:”4,000″,”value”:”4,000″},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/- 2.0% + 5 digits”,”value”:”+/- 2.0% + 5 digits”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/- 2.0% + 4 digits”,”value”:”+/- 2.0% + 4 digits”},{“name”:”Minimum Resistance Measurement”,”normalizedValue”:”400 microohm”,”value”:”400 microohm”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.001 Hz”,”value”:”0.001 Hz”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Capacitance Measurement”,”normalizedValue”:”500 nF”,”value”:”500 nF”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”400 Hz”,”value”:”400 Hz”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/- 1.0% + 4 digits”,”value”:”+/- 1.0% + 4 digits”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/- 3.5% + 6 digits”,”value”:”+/- 3.5% + 6 digits”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”4 V”,”value”:”4 V”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”39 deg F”,”value”:”39 Degrees F”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”3,000 uF”,”value”:”3,000 uF”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”40 megaohm”,”value”:”40 megaohm”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Taiwan, Province of China”,”value”:”Taiwan, Province of China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Digital Clamp Meter, LCD, 600 A, 1.0 in (25 mm) Jaw Capacity, CAT III 600V Safety Rating”