Description
[{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”600″,”rank”:4,”value”:”600″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”600 V”,”rank”:7,”value”:”600 V”},{“name”:”Max. Ohms”,”normalizedValue”:”40,000,000″,”rank”:8,”value”:”40 megaohm”},{“name”:”Jaw Capacity”,”normalizedValue”:”1 in”,”rank”:9,”value”:”1.0 in (25 mm)”},{“name”:”Safety Rating”,”normalizedValue”:”CAT III 600V”,”rank”:11,”value”:”CAT III 600V”},{“name”:”Display”,”normalizedValue”:”LCD”,”rank”:13,”value”:”LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”0.4 in”,”rank”:14,”value”:”0.4 in”},{“name”:”Max. AC Volts”,”normalizedValue”:”600 V”,”rank”:16,”value”:”600 V”},{“name”:”Calibration Frequency”,”normalizedValue”:”50 to 500 Hz”,”rank”:19,”value”:”50 to 500 Hz”},{“name”:”Capacitance”,”normalizedValue”:”3,000 uF”,”value”:”3,000 uF”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Battery Type”,”normalizedValue”:”CR2032″,”value”:”CR2032″},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Peak Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Counter”,”normalizedValue”:”10 Hz to100 kHz with Test Leads; 40 Hz to 400 Hz with Jaw”,”value”:”10 Hz to100 kHz with Test Leads; 40 Hz to 400 Hz with Jaw”},{“name”:”Operating Temp.”,”normalizedValue”:”32 to 104 deg F”,”value”:”32 Degrees to 104 Degrees F”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0% + 5 Digits”,”value”:”+/-2.0% + 5 Digits”},{“name”:”Counts”,”normalizedValue”:”4,000″,”value”:”4,000″},{“name”:”Special Features”,”normalizedValue”:”Features Continuity Beeper to Quickly Find Opens and Shorts, Measures Frequency, Resistance and Capacitance, Residential/Commercial and Small Industrial Applications, Rubber Over-Molded Case Absorbs Shock”,”value”:”Features Continuity Beeper to Quickly Find Opens and Shorts, Measures Frequency, Resistance and Capacitance, Residential/Commercial and Small Industrial Applications, Rubber Over-Molded Case Absorbs Shock”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Includes”,”normalizedValue”:”Manual, Soft Carrying Pouch, Test Leads”,”value”:”Manual, Soft Carrying Pouch, Test Leads”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”40 Hz”,”value”:”40 Hz”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”1.0 in (25mm)”,”value”:”1.0 in (25mm)”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”87 deg F”,”value”:”87 Degrees F”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Minimum DC Voltage Measurement”,”normalizedValue”:”400 mV”,”value”:”400 mV”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/- 0.5%+4 digits”,”value”:”+/- 0.5%+4 digits”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, Continuity, DC Voltage, Frequency, Resistance”,”value”:”AC Current, AC Voltage, Capacitance, Continuity, DC Voltage, Frequency, Resistance”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/- 1.5% + 8 digits”,”value”:”+/- 1.5% + 8 digits”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Battery Size”,”normalizedValue”:”CR2032″,”value”:”CR2032″},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Instrument Counts”,”normalizedValue”:”4,000″,”value”:”4,000″},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/- 2.0% + 5 digits”,”value”:”+/- 2.0% + 5 digits”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/- 2.0% + 4 digits”,”value”:”+/- 2.0% + 4 digits”},{“name”:”Minimum Resistance Measurement”,”normalizedValue”:”400 microohm”,”value”:”400 microohm”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.001 Hz”,”value”:”0.001 Hz”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Capacitance Measurement”,”normalizedValue”:”500 nF”,”value”:”500 nF”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”400 Hz”,”value”:”400 Hz”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/- 1.0% + 4 digits”,”value”:”+/- 1.0% + 4 digits”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/- 3.5% + 6 digits”,”value”:”+/- 3.5% + 6 digits”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”4 V”,”value”:”4 V”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”39 deg F”,”value”:”39 Degrees F”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”3,000 uF”,”value”:”3,000 uF”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”40 megaohm”,”value”:”40 megaohm”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Taiwan, Province of China”,”value”:”Taiwan, Province of China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.