Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”400″,”rank”:4,”value”:”400″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Jaw Capacity”,”normalizedValue”:”1.3 in”,”rank”:9,”value”:”1.3 in (33 mm)”},{“name”:”Safety Rating”,”normalizedValue”:”CAT III 600V”,”rank”:11,”value”:”CAT III 600V”},{“name”:”Display”,”normalizedValue”:”LCD”,”rank”:13,”value”:”LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”1.3 in”,”rank”:14,”value”:”1.3 in”},{“name”:”Calibration Frequency”,”normalizedValue”:”1 yr”,”rank”:19,”value”:”1 yr”},{“name”:”Special Features”,”normalizedValue”:”Fluke 3000 FC DMM, Fluke Connect Mobile app, Fluke Ti200/300/400 Infrared Camera, Inrush Function, Logging Function for Recording and Saving upto 65,000 Readings, Measure upto 400 A AC, PC via optional pc3000 FC Adapter, use as A Standalone Meter or as Part of the System”,”value”:”Fluke 3000 FC DMM, Fluke Connect Mobile app, Fluke Ti200/300/400 Infrared Camera, Inrush Function, Logging Function for Recording and Saving upto 65,000 Readings, Measure upto 400 A AC, PC via optional pc3000 FC Adapter, use as A Standalone Meter or as Part of the System”},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Audible Continuity”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Bar Graph”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Inrush”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Diode Test”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Data Hold”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Operating Temp.”,”normalizedValue”:”50 to 122 deg F”,”value”:”50 Degrees to 122 Degrees F”},{“name”:”Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Memory”,”normalizedValue”:”Max/Min/Avg”,”value”:”Max/Min/Avg”},{“name”:”Includes”,”normalizedValue”:”Quick Start Guide Only”,”value”:”Quick Start Guide Only”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Standards”,”normalizedValue”:”CE, CSA, FCC: T68-FBLE IC: 6627A-FBLE”,”value”:”CE, CSA, FCC: T68-FBLE IC: 6627A-FBLE”},{“name”:”Battery Type”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”Calibration Certificate”,”normalizedValue”:”No”,”value”:”Not Included”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0% + 5 Digits”,”value”:”+/-2.0% + 5 Digits”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Max. Conductor Size”,”normalizedValue”:”1.18 in (30.0mm)”,”value”:”1.18 in (30.0mm)”},{“name”:”Peak Hold”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Thermometer Type”,”normalizedValue”:”Type K Thermocouple”,”value”:”Type K Thermocouple”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bar Graph Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Instrument Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Overall Height”,”normalizedValue”:”2 in”,”value”:”2 in”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”IP Rating”,”normalizedValue”:”IP30″,”value”:”IP30″},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Overall Width”,”normalizedValue”:”3.8 in”,”value”:”3.8 in”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”400 A”,”value”:”400 A”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Battery Size”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”0.1 A”,”value”:”0.1 A”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”0.1 A”,”value”:”0.1 A”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, Inrush AC Current, Temperature (K)”,”value”:”AC Current, Inrush AC Current, Temperature (K)”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”400.0 A: 2% +/- 5 digits (10 Hz to 100 Hz), 2.5% +/- 5 digits (100 Hz to 500 Hz)”,”value”:”400.0 A: 2% +/- 5 digits (10 Hz to 100 Hz), 2.5% +/- 5 digits (100 Hz to 500 Hz)”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”1.18 in (30.0mm)”,”value”:”1.18 in (30.0mm)”},{“name”:”Inrush Current Measurable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.