Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Split”,”rank”:6,”value”:”Split”},{“name”:”Jaw Capacity”,”normalizedValue”:”2-1/2 in”,”rank”:9,”value”:”2.5 in (64 mm)”},{“name”:”Safety Rating”,”normalizedValue”:”CAT IV 600V, CAT III 1000V”,”rank”:11,”value”:”CAT III 1000V, CAT IV 600V”},{“name”:”Display”,”normalizedValue”:”LCD”,”rank”:13,”value”:”LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”2-1/2 in”,”rank”:14,”value”:”2.5 in”},{“name”:”Max. DC Amps”,”normalizedValue”:”2,000″,”rank”:15,”value”:”2,000″},{“name”:”Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Battery Type”,”normalizedValue”:”AA”,”value”:”(2) AA”},{“name”:”Bar Graph”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Operating Temp.”,”normalizedValue”:”50 to 122 deg F”,”value”:”50 Degrees to 122 Degrees F”},{“name”:”Includes”,”normalizedValue”:”Hanging Strap, Magnet, Quick Start Guide Only”,”value”:”Hanging Strap, Magnet, Quick Start Guide Only”},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Peak Hold”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Audible Continuity”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Max. Conductor Size”,”normalizedValue”:”2.50 in (25.4mm)”,”value”:”2.50 in (25.4mm)”},{“name”:”Diode Test”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Data Hold”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Standards”,”normalizedValue”:”CE, CSA, FCC: T68-FBLE IC: 6627A-FBLE”,”value”:”CE, CSA, FCC: T68-FBLE IC: 6627A-FBLE”},{“name”:”Special Features”,”normalizedValue”:”Logging”,”value”:”Logging”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0% + 5 Digits”,”value”:”+/-2.0% + 5 Digits”},{“name”:”Calibration Certificate”,”normalizedValue”:”No”,”value”:”Not Included”},{“name”:”Inrush”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Thermometer Type”,”normalizedValue”:”Type K Thermocouple”,”value”:”Type K Thermocouple”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Parameters Measured”,”normalizedValue”:”DC Current, Temperature (K)”,”value”:”DC Current, Temperature (K)”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Jaw Style”,”normalizedValue”:”Open-Jaw”,”value”:”Open-Jaw”},{“name”:”AC Response Calculation”,”normalizedValue”:”Average”,”value”:”Average”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”IP Rating”,”normalizedValue”:”IP42″,”value”:”IP42″},{“name”:”Overall Width”,”normalizedValue”:”2-1/2 in”,”value”:”2.5 in”},{“name”:”Battery Size”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”Overall Height”,”normalizedValue”:”6-1/2 in”,”value”:”6.5 in”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bar Graph Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”2,000 A”,”value”:”2,000 A”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”2.50 in (25.4mm)”,”value”:”2.50 in (25.4mm)”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Instrument Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”0.1 A”,”value”:”0.1 A”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Inrush Current Measurable”,”normalizedValue”:”No”,”value”:”No”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”0.1 A”,”value”:”0.1 A”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”2% +/- 5 digits”,”value”:”2% +/- 5 digits”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.