Digital Clamp Meter, LCD, 1,500 A, 2.0 in (51 mm) Jaw Capacity, CAT IV 600V Safety Rating

$242,99

Digital Clamp Meter, Audible Continuity Yes, Safety Rating CAT IV 600V, AC Response Calculation TRMS, Maximum AC Current Measurement 1,500 A, Maximum AC Voltage Measurement 750 V, Maximum DC Current Measurement 1,500 A, Maximum DC Voltage Measurement 1,000 V, Current Leakage Testing No, Parameters Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Duty Cycle, Frequency, Inrush AC Current, Resistance, Temperature (K), Intrinsically Safe No, Dustproof No

9999 in stock

SKU: GRG2390306 Category:

Description

[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”1,500″,”rank”:4,”value”:”1,500″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”1,000 V”,”rank”:7,”value”:”1,000 V”},{“name”:”Max. Ohms”,”normalizedValue”:”40,000,000″,”rank”:8,”value”:”40 megaohm”},{“name”:”Jaw Capacity”,”normalizedValue”:”2 in”,”rank”:9,”value”:”2.0 in (51 mm)”},{“name”:”Temp. Range”,”normalizedValue”:”-148 to 1,832 deg F”,”rank”:10,”value”:”-148 Degrees to 1832 Degrees F”},{“name”:”Safety Rating”,”normalizedValue”:”CAT IV 600V”,”rank”:11,”value”:”CAT IV 600V”},{“name”:”Display”,”normalizedValue”:”LCD”,”rank”:13,”value”:”LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”2 in”,”rank”:14,”value”:”2 in”},{“name”:”Max. DC Amps”,”normalizedValue”:”1,500″,”rank”:15,”value”:”1,500″},{“name”:”Max. AC Volts”,”normalizedValue”:”750 V”,”rank”:16,”value”:”750 V”},{“name”:”Calibration Frequency”,”normalizedValue”:”50 to 60 Hz”,”rank”:19,”value”:”50 to 60 Hz”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Capacitance”,”normalizedValue”:”40 nF”,”value”:”40 nF”},{“name”:”Operating Temp.”,”normalizedValue”:”32 to 122 deg F”,”value”:”32 Degrees to 122 Degrees F”},{“name”:”Memory”,”normalizedValue”:”Max/Min”,”value”:”Max/Min”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Special Features”,”normalizedValue”:”2.0\” (52mm) jaw size for conductors up to 500MCM, Built-in non-contact Voltage detector with LED alert, Data Hold, Peak Hold, MIN/MAX, and Auto Power Off, Dual 40,000/4000 count, backlit LCD display, Inrush function captures transients during motor startups, Relative Mode for Capacitance Zero and Offset Adjustment”,”value”:”2.0\” (52mm) jaw size for conductors up to 500MCM, Built-in non-contact Voltage detector with LED alert, Data Hold, Peak Hold, MIN/MAX, and Auto Power Off, Dual 40,000/4000 count, backlit LCD display, Inrush function captures transients during motor startups, Relative Mode for Capacitance Zero and Offset Adjustment”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0% + 5 Digits”,”value”:”+/-2.0% + 5 Digits”},{“name”:”Thermometer Type”,”normalizedValue”:”Type K Thermocouple”,”value”:”Type K Thermocouple”},{“name”:”Frequency Counter”,”normalizedValue”:”40 MHz”,”value”:”40 MHz”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Max. Conductor Size”,”normalizedValue”:”500 kcmil”,”value”:”500 kcmil”},{“name”:”Battery Type”,”normalizedValue”:”9V”,”value”:”9V”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Includes”,”normalizedValue”:”Carrying Case, Test Leads, Type K Bead Wire Temperature Probe”,”value”:”Carrying Case, Test Leads, Type K Bead Wire Temperature Probe”},{“name”:”Counts”,”normalizedValue”:”4,000, 40,000″,”value”:”4,000, 40,000″},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Peak Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Standards”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”40 megaohm”,”value”:”40 megaohm”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”500MCM”,”value”:”500MCM”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”+/-2.50%”,”value”:”+/-2.50%”},{“name”:”Inrush Current Measurable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”0.01 A”,”value”:”0.01 A”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”40 Hz”,”value”:”40 Hz”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-0.30%”,”value”:”+/-0.30%”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-3.00%”,”value”:”+/-3.00%”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”41 deg F”,”value”:”41 Degrees F”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-2.80%”,”value”:”+/-2.80%”},{“name”:”Minimum DC Voltage Measurement”,”normalizedValue”:”400 mV”,”value”:”400 mV”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Minimum Resistance Measurement”,”normalizedValue”:”400 ohm”,”value”:”400 ohm”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”40 MHz”,”value”:”40 MHz”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”400 A”,”value”:”400 A”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”40 mF”,”value”:”40 mF”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”1,500 A”,”value”:”1,500 A”},{“name”:”Overall Width”,”normalizedValue”:”4.1 in”,”value”:”4.1 in”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Capacitance Measurement Resolution”,”normalizedValue”:”0.01 nF”,”value”:”0.01 nF”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Display Type”,”normalizedValue”:”Backlit LCD”,”value”:”Backlit LCD”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Duty Cycle, Frequency, Inrush AC Current, Resistance, Temperature (K)”,”value”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Duty Cycle, Frequency, Inrush AC Current, Resistance, Temperature (K)”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum DC Current Measurement”,”normalizedValue”:”400 A”,”value”:”400 A”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”0.01 mV”,”value”:”0.01 mV”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”0.01 mV”,”value”:”0.01 mV”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”750 V”,”value”:”750 V”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Overall Height”,”normalizedValue”:”1.9 in”,”value”:”1.9 in”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-0.50%”,”value”:”+/-0.50%”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-5.00%”,”value”:”+/-5.00%”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:”0.01 ohm”,”value”:”0.01 ohm”},{“name”:”Instrument Counts”,”normalizedValue”:”4,000/40,000″,”value”:”4,000/40,000″},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”0.01 A”,”value”:”0.01 A”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”400 V”,”value”:”400 V”},{“name”:”Battery Size”,”normalizedValue”:”9V”,”value”:”9V”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”1,500 A”,”value”:”1,500 A”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.001 Hz”,”value”:”0.001 Hz”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Digital Clamp Meter, LCD, 1,500 A, 2.0 in (51 mm) Jaw Capacity, CAT IV 600V Safety Rating”