Digital Clamp Meter, LCD, 1,000 A, 2.0 in (51 mm) Jaw Capacity

$379,99

Digital Clamp Meter, Audible Continuity Yes, Safety Rating CAT III 1000V, CAT IV 600V, AC Response Calculation TRMS, Maximum AC Current Measurement 600 A, Maximum AC Voltage Measurement 1,000 V, Maximum DC Current Measurement 1,000 A, Maximum DC Voltage Measurement 1,000 V, Current Leakage Testing No, Parameters Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K), Intrinsically Safe No, Dustproof No, Waterproof No, Data Logging Yes

9999 in stock

SKU: GRG9486477 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”1,000″,”rank”:4,”value”:”1,000″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”1,000 V”,”rank”:7,”value”:”1,000 V”},{“name”:”Max. Ohms”,”normalizedValue”:”60,000″,”rank”:8,”value”:”60,000″},{“name”:”Jaw Capacity”,”normalizedValue”:”2 in”,”rank”:9,”value”:”2.0 in (51 mm)”},{“name”:”Temp. Range”,”normalizedValue”:”-40 to 752 deg F”,”rank”:10,”value”:”-40 Degrees to 752 Degrees F”},{“name”:”Safety Rating”,”normalizedValue”:”CAT IV 600V, CAT III 1000V”,”rank”:11,”value”:”CAT III 1000V, CAT IV 600V”},{“name”:”Display”,”normalizedValue”:”LCD”,”rank”:13,”value”:”LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”2 in”,”rank”:14,”value”:”2 in”},{“name”:”Max. DC Amps”,”normalizedValue”:”1,000″,”rank”:15,”value”:”1,000″},{“name”:”Max. AC Volts”,”normalizedValue”:”1,000 V”,”rank”:16,”value”:”1,000 V”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Includes”,”normalizedValue”:”Carrying Case, K Type Banana Plug Thermocouple, Manual, Test Leads with Alligator Clips”,”value”:”Carrying Case, K Type Banana Plug Thermocouple, Manual, Test Leads with Alligator Clips”},{“name”:”Max. Conductor Size”,”normalizedValue”:”2.00 in (51.0mm)”,”value”:”2.00 in (51.0mm)”},{“name”:”Bar Graph”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Peak Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Type”,”normalizedValue”:”AAA”,”value”:”AAA”},{“name”:”Standards”,”normalizedValue”:”CE, cULus”,”value”:”CE, cULus”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Capacitance”,”normalizedValue”:”2,500 uF”,”value”:”2,500 uF”},{“name”:”Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Calibration Certificate”,”normalizedValue”:”No”,”value”:”Not Included”},{“name”:”Frequency Counter”,”normalizedValue”:”5 Hz to 999.9 Hz”,”value”:”5 Hz to 999.9 Hz”},{“name”:”Inrush”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Temp.”,”normalizedValue”:”14 to 122 deg F”,”value”:”14 Degrees to 122 Degrees F”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0% + 5 Digits”,”value”:”+/-2.0% + 5 Digits”},{“name”:”Special Features”,”normalizedValue”:”Amp Tip Function”,”value”:”Amp Tip Function”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Thermometer Type”,”normalizedValue”:”Type K Thermocouple”,”value”:”Type K Thermocouple”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K)”,”value”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K)”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-2.0% + 4LSD”,”value”:”+/-2.0% + 4LSD”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Inrush Current Measurable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Instrument Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”2,500 uF”,”value”:”2,500 uF”},{“name”:”Battery Size”,”normalizedValue”:”AAA”,”value”:”AAA”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-1.0% + 5LSD”,”value”:”+/-1.0% + 5LSD”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-0.8% + 5LSD (50 to 60 Hz)”,”value”:”+/-0.8% + 5LSD (50 to 60 Hz)”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”1,000 A”,”value”:”1,000 A”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-1.0% + 5LSD”,”value”:”+/-1.0% + 5LSD”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”60,000 ohm”,”value”:”60,000 ohm”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-1.8% + 5LSD (50 to 60 Hz) +/-2.0% + 5LSD (100 to 400 Hz)”,”value”:”+/-1.8% + 5LSD (50 to 60 Hz) +/-2.0% + 5LSD (100 to 400 Hz)”},{“name”:”Bar Graph Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”2.00 in (51.0mm)”,”value”:”2.00 in (51.0mm)”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-1.00% + 5 LSD (600 V Range); +/-2.00% + 4 LSD (600 A Range)”,”value”:”+/-1.00% + 5 LSD (600 V Range); +/-2.00% + 4 LSD (600 A Range)”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”+/-1.8% + 5LSD (DC 50 to 100 Hz)”,”value”:”+/-1.8% + 5LSD (DC 50 to 100 Hz)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Taiwan, Province of China”,”value”:”Taiwan, Province of China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Digital Clamp Meter, LCD, 1,000 A, 2.0 in (51 mm) Jaw Capacity”