Digital Clamp Meter, Color TFT, 600 A, 1.3 in (33 mm) Jaw Capacity, CAT IV 600V Safety Rating

$817,99

Digital Clamp Meter, Audible Continuity Yes, Safety Rating CAT IV 600V, AC Response Calculation TRMS, Maximum AC Current Measurement 600 A, Maximum AC Voltage Measurement 1,000 V, Maximum DC Current Measurement 600 A, Maximum DC Voltage Measurement 1,000 V, Current Leakage Testing No, Parameters Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature (IR), Intrinsically Safe No, Dustproof No, Waterproof No, Data Logging Yes

Out of stock

SKU: GRG3900053 Category:

Description

[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”600″,”rank”:4,”value”:”600″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”1,000 V”,”rank”:7,”value”:”1,000 V”},{“name”:”Max. Ohms”,”normalizedValue”:”6,000″,”rank”:8,”value”:”6000″},{“name”:”Jaw Capacity”,”normalizedValue”:”1.3 in”,”rank”:9,”value”:”1.3 in (33 mm)”},{“name”:”Temp. Range”,”normalizedValue”:”14 to 302 deg F”,”rank”:10,”value”:”14 Degrees to 302 Degrees F”},{“name”:”Safety Rating”,”normalizedValue”:”CAT IV 600V”,”rank”:11,”value”:”CAT IV 600V”},{“name”:”Display”,”normalizedValue”:”Color TFT”,”rank”:13,”value”:”Color TFT”},{“name”:”Jaw Opening”,”normalizedValue”:”1.3 in”,”rank”:14,”value”:”1.3 in”},{“name”:”Max. DC Amps”,”normalizedValue”:”600″,”rank”:15,”value”:”600″},{“name”:”Max. AC Volts”,”normalizedValue”:”1,000 V”,”rank”:16,”value”:”1,000 V”},{“name”:”Calibration Frequency”,”normalizedValue”:”50 to 60 Hz”,”rank”:19,”value”:”50 to 60 Hz”},{“name”:”Calibration Certificate”,”normalizedValue”:”No”,”value”:”Not Included”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Capacitance”,”normalizedValue”:”1,000 uF”,”value”:”1,000 uF”},{“name”:”Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”10 yr”,”value”:”10 yr”},{“name”:”Includes”,”normalizedValue”:”(3) Lithium Batteries, Soft Carrying Case, Test Leads”,”value”:”(3) Lithium Batteries, Soft Carrying Case, Test Leads”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Max. Conductor Size”,”normalizedValue”:”1.30 in (35.0mm)”,”value”:”1.30 in (35.0mm)”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Counter”,”normalizedValue”:”10 kHz”,”value”:”10 kHz”},{“name”:”Thermometer Type”,”normalizedValue”:”Infrared”,”value”:”Infrared”},{“name”:”Operating Temp.”,”normalizedValue”:”32 to 122 deg F”,”value”:”32 Degrees to 122 Degrees F”},{“name”:”Bar Graph”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Standards”,”normalizedValue”:”CE, cULus”,”value”:”CE, cULus”},{“name”:”Peak Hold”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Battery Type”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0%”,”value”:”+/-2.0%”},{“name”:”Special Features”,”normalizedValue”:”Diagnose complex systems with high and low voltage measurement capabilities, Easily reach difficult, dark locations thanks to narrow jaw and built-in worklights, Expand measurement capabilities to 3000 A AC with FLIR Flex Clamp accessories, Pinpoint exact hot spot locations with laser or crosshairs, Rely on the protection of CAT IV-600V, CAT III-1000V safety ratings, Safely check for live connections using non-contact temperature measurement, Scan entire targets for electrical issues with up to 160 × 120 thermal resolution, Simplify data and thermal imaging collection and produce instant reports by connecting via METERLiNK to a smartphone or tablet running the FLIR Tools app, Store electrical measurements and thermal images internally”,”value”:”Diagnose complex systems with high and low voltage measurement capabilities, Easily reach difficult, dark locations thanks to narrow jaw and built-in worklights, Expand measurement capabilities to 3000 A AC with FLIR Flex Clamp accessories, Pinpoint exact hot spot locations with laser or crosshairs, Rely on the protection of CAT IV-600V, CAT III-1000V safety ratings, Safely check for live connections using non-contact temperature measurement, Scan entire targets for electrical issues with up to 160 × 120 thermal resolution, Simplify data and thermal imaging collection and produce instant reports by connecting via METERLiNK to a smartphone or tablet running the FLIR Tools app, Store electrical measurements and thermal images internally”},{“name”:”Memory”,”normalizedValue”:”40,000 Readings”,”value”:”40,000 Readings”},{“name”:”Inrush”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-2.00%”,”value”:”+/-2.00%”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”1,000 uF”,”value”:”1,000 uF”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Battery Size”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Bar Graph Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Overall Height”,”normalizedValue”:”9-1/2 in”,”value”:”9.5 in”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”302 deg F”,”value”:”302 Degrees F”},{“name”:”Instrument Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Inrush Current Measurable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Battery Chemistry”,”normalizedValue”:”Li-Poly”,”value”:”Li-Poly”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”10 kHz”,”value”:”10 kHz”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature (IR)”,”value”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature (IR)”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”60 V”,”value”:”60 V”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”1.30 in (35.0mm)”,”value”:”1.30 in (35.0mm)”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-0.10%”,”value”:”+/-0.10%”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”60 V”,”value”:”60 V”},{“name”:”Thermal Imaging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Overall Width”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Display Type”,”normalizedValue”:”TFT LCD”,”value”:”TFT LCD”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”6,000 ohm”,”value”:”6,000 ohm”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Taiwan, Province of China”,”value”:”Taiwan, Province of China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Digital Clamp Meter, Color TFT, 600 A, 1.3 in (33 mm) Jaw Capacity, CAT IV 600V Safety Rating”