Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”60″,”rank”:4,”value”:”60″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”600 V”,”rank”:7,”value”:”600 V”},{“name”:”Max. Ohms”,”normalizedValue”:”60,000,000″,”rank”:8,”value”:”60 megaohm”},{“name”:”Jaw Capacity”,”normalizedValue”:”0.7 in”,”rank”:9,”value”:”0.7 in (18 mm)”},{“name”:”Safety Rating”,”normalizedValue”:”CAT III 300V, CAT II 600V”,”rank”:11,”value”:”CAT II 600V, CAT III 300V”},{“name”:”Display”,”normalizedValue”:”Backlit LCD”,”rank”:13,”value”:”Backlit LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”0.7 in”,”rank”:14,”value”:”0.7 in”},{“name”:”Max. DC Amps”,”normalizedValue”:”60″,”rank”:15,”value”:”60″},{“name”:”Max. AC Volts”,”normalizedValue”:”600 V”,”rank”:16,”value”:”600 V”},{“name”:”Calibration Frequency”,”normalizedValue”:”50 to 60 Hz”,”rank”:19,”value”:”50 to 60 Hz”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Special Features”,”normalizedValue”:”0.7\” (17mm) jaw size allows measurements in tight locations, 6000 count backlit LCD display, Built-in non-contact voltage detector (NCV) with LED indicator, Data Hold, Low Battery indicator, Auto Power Off, Full range overload protection, Variable Frequency Control (VFC): Low pass filter for accurate measurements of variable frequency drive signals”,”value”:”0.7\” (17mm) jaw size allows measurements in tight locations, 6000 count backlit LCD display, Built-in non-contact voltage detector (NCV) with LED indicator, Data Hold, Low Battery indicator, Auto Power Off, Full range overload protection, Variable Frequency Control (VFC): Low pass filter for accurate measurements of variable frequency drive signals”},{“name”:”Frequency Counter”,”normalizedValue”:”10 Hz to 60 KHz”,”value”:”10 Hz to 60 KHz”},{“name”:”Peak Hold”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Temp.”,”normalizedValue”:”32 to 104 deg F”,”value”:”32 Degrees to 104 Degrees F”},{“name”:”Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0%”,”value”:”+/-2.0%”},{“name”:”Bar Graph”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Calibration Certificate”,”normalizedValue”:”No”,”value”:”Not Included”},{“name”:”Capacitance”,”normalizedValue”:”62 mF”,”value”:”62 mF”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Type”,”normalizedValue”:”AAA”,”value”:”AAA”},{“name”:”Max. Conductor Size”,”normalizedValue”:”300 kcmil”,”value”:”300 kcmil”},{“name”:”Standards”,”normalizedValue”:”CE, cULus”,”value”:”CE, cULus”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Inrush”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Includes”,”normalizedValue”:”(2) AAA Batteries, Carrying Case, Test Leads”,”value”:”(2) AAA Batteries, Carrying Case, Test Leads”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-2.50%”,”value”:”+/-2.50%”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”+/-2.00%”,”value”:”+/-2.00%”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-0.10%”,”value”:”+/-0.10%”},{“name”:”Overall Height”,”normalizedValue”:”1.3 in”,”value”:”1.3 in”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”60 A”,”value”:”60 A”},{“name”:”Inrush Current Measurable”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-10.00%”,”value”:”+/-10.00%”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Inrush AC Current, Resistance”,”value”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Inrush AC Current, Resistance”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”1 mA”,”value”:”1 mA”},{“name”:”Capacitance Measurement Resolution”,”normalizedValue”:”1 pF”,”value”:”1 pF”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”0.1 mA”,”value”:”0.1 mA”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”60 kHz”,”value”:”60 kHz”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”1,000 A”,”value”:”1,000 A”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”1 mV”,”value”:”1 mV”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Bar Graph Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum DC Current Measurement”,”normalizedValue”:”6 A”,”value”:”6 A”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-1.50%”,”value”:”+/-1.50%”},{“name”:”Instrument Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Capacitance Measurement”,”normalizedValue”:”6.2 nF”,”value”:”6.2 nF”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”10 Hz”,”value”:”10 Hz”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”300MCM”,”value”:”300MCM”},{“name”:”Display Type”,”normalizedValue”:”Backlit LCD”,”value”:”Backlit LCD”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”62 mF”,”value”:”62 mF”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Overall Width”,”normalizedValue”:”2.4 in”,”value”:”2.4 in”},{“name”:”Battery Size”,”normalizedValue”:”AAA”,”value”:”AAA”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”6 V”,”value”:”6 V”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”0.1 mV”,”value”:”0.1 mV”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.001 Hz”,”value”:”0.001 Hz”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”600 mA”,”value”:”600 mA”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Resistance Measurement”,”normalizedValue”:”600 ohm”,”value”:”600 ohm”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”60 megaohm”,”value”:”60 megaohm”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:”0.1 ohm”,”value”:”0.1 ohm”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-0.70%”,”value”:”+/-0.70%”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.