Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”1,000 A”,”rank”:4,”value”:”1,000 A”},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”1,500 V”,”rank”:7,”value”:”1,500 V”},{“name”:”Max. Ohms”,”normalizedValue”:”600″,”rank”:8,”value”:”600 ohm”},{“name”:”Jaw Capacity”,”normalizedValue”:”1.3 in”,”rank”:9,”value”:”1.3 in (33 mm)”},{“name”:”Safety Rating”,”normalizedValue”:”CAT IV 600V, CAT III 1500V”,”rank”:11,”value”:”CAT III 1500V, CAT IV 600V”},{“name”:”Display”,”normalizedValue”:”Backlit LCD”,”rank”:13,”value”:”Backlit LCD”},{“name”:”Jaw Opening”,”normalizedValue”:”1.3 in”,”rank”:14,”value”:”1.3 in”},{“name”:”Max. DC Amps”,”normalizedValue”:”1,000 A”,”rank”:15,”value”:”1,000 A”},{“name”:”Max. AC Volts”,”normalizedValue”:”1,000 V”,”rank”:16,”value”:”1,000 V”},{“name”:”Calibration Frequency”,”normalizedValue”:”5 to 500 Hz”,”rank”:19,”value”:”5 to 500 Hz”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Includes”,”normalizedValue”:”Carrying Case, CAT III 1500V Rated, Fluke 393 FC CAT III 1500 V True-RMS Clamp Meter with iFlex, iFlex 18 in Flexible Current Probe, Right Angle Plugs with Safety Caps, Test Leads, TPAK Magnetic Hanging Strap”,”value”:”Carrying Case, CAT III 1500V Rated, Fluke 393 FC CAT III 1500 V True-RMS Clamp Meter with iFlex, iFlex 18 in Flexible Current Probe, Right Angle Plugs with Safety Caps, Test Leads, TPAK Magnetic Hanging Strap”},{“name”:”Capacitance”,”normalizedValue”:”1,000 uF”,”value”:”1,000 uF”},{“name”:”Memory”,”normalizedValue”:”Max/Min”,”value”:”Max/Min”},{“name”:”Frequency Counter”,”normalizedValue”:”5 Hz to 500 Hz”,”value”:”5 Hz to 500 Hz”},{“name”:”Inrush”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Temp.”,”normalizedValue”:”18 to 28 deg C”,”value”:”18 Degrees to 28 Degrees C”},{“name”:”Peak Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Special Features”,”normalizedValue”:”Designed for Technicians Who Work in High Voltage DC Environment: Solar Arrays, Wind Power, Electric Railways, Data Centers Battery Banks for Uninterruptible Power Supplies”,”value”:”Designed for Technicians Who Work in High Voltage DC Environment: Solar Arrays, Wind Power, Electric Railways, Data Centers Battery Banks for Uninterruptible Power Supplies”},{“name”:”Diode Test”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Thermometer Type”,”normalizedValue”:”Type K Thermocouple”,”value”:”Type K Thermocouple”},{“name”:”Standards”,”normalizedValue”:”IEC/EN61010-031″,”value”:”IEC/EN61010-031″},{“name”:”Calibration Certificate”,”normalizedValue”:”No”,”value”:”Not Included”},{“name”:”Max. Conductor Size”,”normalizedValue”:”34 mm”,”value”:”34 mm”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2 % + 5 Digits”,”value”:”+/-2 % + 5 Digits”},{“name”:”Battery Type”,”normalizedValue”:”AA Alkaline”,”value”:”(2) AA Alkaline”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Display Type”,”normalizedValue”:”Backlit LCD”,”value”:”Backlit LCD”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”0.1 V”,”value”:”0.1 V”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”0.1 V”,”value”:”0.1 V”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”1 % RD + 5 digits”,”value”:”1 % RD + 5 digits”},{“name”:”Capacitance Measurement Resolution”,”normalizedValue”:”100 uF”,”value”:”100 uF”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”1,000 A”,”value”:”1,000 A”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”Jaw: 2 % + 5 digits (10 Hz to 100 Hz) 2.5 % + 5 digits (100 Hz to 500 Hz)Flexible Probe: 3 % RD + 5 digits (10 Hz to 500 Hz)”,”value”:”Jaw: 2 % + 5 digits (10 Hz to 100 Hz) 2.5 % + 5 digits (100 Hz to 500 Hz)Flexible Probe: 3 % RD + 5 digits (10 Hz to 500 Hz)”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”0.1 A”,”value”:”0.1 A”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”0.5 % RD + 5 digits”,”value”:”0.5 % RD + 5 digits”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”2 % RD + 5 digits”,”value”:”2 % RD + 5 digits”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”600 ohm”,”value”:”600 ohm”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K)”,”value”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature (K)”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”28 deg F”,”value”:”28 Degrees F”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,500 V”,”value”:”1,500 V”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Size”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”IP Rating”,”normalizedValue”:”IP54″,”value”:”IP54″},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”1,000 uF”,”value”:”1,000 uF”},{“name”:”Inrush Current Measurable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”0.1 A”,”value”:”0.1 A”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”18 deg F”,”value”:”18 Degrees F”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:”0.1 ohm”,”value”:”0.1 ohm”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”1.33 in (34mm)”,”value”:”1.33 in (34mm)”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”1 % RD + 5 digits (20 Hz to 500 Hz)”,”value”:”1 % RD + 5 digits (20 Hz to 500 Hz)”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”1 % RD + 5 digits”,”value”:”1 % RD + 5 digits”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”1 % RD + 5 digits”,”value”:”1 % RD + 5 digits”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”1,000 A”,”value”:”1,000 A”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.1 Hz”,”value”:”0.1 Hz”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.