Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Clamp Meter”,”rank”:1,”value”:”Digital Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Max. AC Amps”,”normalizedValue”:”2,000″,”rank”:4,”value”:”2,000″},{“name”:”Clamp Meter Jaw Style”,”normalizedValue”:”Clamp On”,”rank”:6,”value”:”Clamp On”},{“name”:”Max. DC Volts”,”normalizedValue”:”1,000 V”,”rank”:7,”value”:”1,000 V”},{“name”:”Max. Ohms”,”normalizedValue”:”40,000,000″,”rank”:8,”value”:”40 megaohm”},{“name”:”Jaw Capacity”,”normalizedValue”:”2 in”,”rank”:9,”value”:”2.0 in (51 mm)”},{“name”:”Safety Rating”,”normalizedValue”:”CAT IV 600V”,”rank”:11,”value”:”CAT IV 600V”},{“name”:”Display”,”normalizedValue”:”Backlit”,”rank”:13,”value”:”Backlit”},{“name”:”Jaw Opening”,”normalizedValue”:”2 in”,”rank”:14,”value”:”2 in”},{“name”:”Max. DC Amps”,”normalizedValue”:”400″,”rank”:15,”value”:”400″},{“name”:”Max. AC Volts”,”normalizedValue”:”1,000 V”,”rank”:16,”value”:”1,000 V”},{“name”:”Calibration Frequency”,”normalizedValue”:”50 to 60 Hz”,”rank”:19,”value”:”50 to 60 Hz”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Battery Type”,”normalizedValue”:”9V”,”value”:”9V”},{“name”:”Capacitance”,”normalizedValue”:”50″,”value”:”50″},{“name”:”Frequency Counter”,”normalizedValue”:”100 KHz”,”value”:”100 KHz”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Includes”,”normalizedValue”:”Test Leads”,”value”:”Test Leads”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Current Accuracy”,”normalizedValue”:”+/-2.0% + 5 Digits”,”value”:”+/-2.0% + 5 Digits”},{“name”:”Max. Conductor Size”,”normalizedValue”:”200 kcmil or (2) 500 kcmil”,”value”:”200 kcmil or (2) 500 kcmil”},{“name”:”AC Response”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Special Features”,”normalizedValue”:”AC/DC Current via clamp with 0.1A resolution, Large Backlit display, Large jaw size for high Current measurements, Push button Zero adjust improves DC accuracy”,”value”:”AC/DC Current via clamp with 0.1A resolution, Large Backlit display, Large jaw size for high Current measurements, Push button Zero adjust improves DC accuracy”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Counts”,”normalizedValue”:”5,000″,”value”:”5,000″},{“name”:”Operating Temp.”,”normalizedValue”:”32 to 122 deg F”,”value”:”32 Degrees to 122 Degrees F”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Standards”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Overall Width”,”normalizedValue”:”2.9 in”,”value”:”2.9 in”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp-Jaw”,”value”:”Clamp-Jaw”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”2,000 A”,”value”:”2,000 A”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Capacitance Measurement Resolution”,”normalizedValue”:”10 uF”,”value”:”10 uF”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Display Type”,”normalizedValue”:”Backlit LCD”,”value”:”Backlit LCD”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Resistance Measurement”,”normalizedValue”:”400 ohm”,”value”:”400 ohm”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”1 mV”,”value”:”1 mV”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”50 uF”,”value”:”50 uF”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”4 V”,”value”:”4 V”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”0.1 A”,”value”:”0.1 A”},{“name”:”Minimum DC Current Measurement”,”normalizedValue”:”400 A”,”value”:”400 A”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-3.50%”,”value”:”+/-3.50%”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”100 kHz”,”value”:”100 kHz”},{“name”:”Instrument Counts”,”normalizedValue”:”5,000″,”value”:”5,000″},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”+/-2.00%”,”value”:”+/-2.00%”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.001 Hz”,”value”:”0.001 Hz”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:”0.1 ohm”,”value”:”0.1 ohm”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-3.00 %”,”value”:”+/-3.00 %”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Battery Size”,”normalizedValue”:”9V”,”value”:”9V”},{“name”:”Overall Height”,”normalizedValue”:”1-1/2 in”,”value”:”1.5 in”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”40 megaohm”,”value”:”40 megaohm”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”400 A”,”value”:”400 A”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum DC Voltage Measurement”,”normalizedValue”:”400 mV”,”value”:”400 mV”},{“name”:”Maximum Conductor Size”,”normalizedValue”:”750MCM”,”value”:”750MCM”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-1.20%”,”value”:”+/-1.20%”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Duty Cycle, Frequency, Resistance”,”value”:”AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Duty Cycle, Frequency, Resistance”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”2,000 A”,”value”:”2,000 A”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”0.1 uA, 0.1 A”,”value”:”0.1 uA, 0.1 A”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”5 Hz”,”value”:”5 Hz”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-2.00%”,”value”:”+/-2.00%”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”0.1 mV”,”value”:”0.1 mV”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Taiwan, Province of China”,”value”:”Taiwan, Province of China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.