Description
[{“name”:”Item”,”normalizedValue”:”Defrost Control Timer”,”rank”:1,”value”:”Defrost Control Timer”},{“name”:”Voltage”,”normalizedValue”:”120/240V AC”,”rank”:2,”value”:”120/240V AC”},{“name”:”Amps”,”normalizedValue”:”40″,”rank”:3,”value”:”40 A”},{“name”:”Contact Type”,”normalizedValue”:”1 NC, 1 NO”,”rank”:4,”value”:”1 NO/1 NC”},{“name”:”Max. On/Off Cycles”,”normalizedValue”:”48 Per Day”,”rank”:5,”value”:”48 Per Day”},{“name”:”Defrost Time (Minutes)”,”normalizedValue”:”15 to 1425″,”rank”:6,”value”:”15 to 1425″},{“name”:”Enclosure Material”,”normalizedValue”:”Plastic”,”rank”:7,”value”:”Plastic”},{“name”:”Termination Type”,”normalizedValue”:”Temperature or Pressure, Time”,”rank”:8,”value”:”Temperature or Pressure, Time”},{“name”:”Defrost Initiation”,”normalizedValue”:”Time”,”value”:”Time”},{“name”:”Wiring Option”,”normalizedValue”:”Screw box lug terminals up to one #8 AWG wire”,”value”:”Screw box lug terminals up to one #8 AWG wire”},{“name”:”Has Realtime Clock Face CVL”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Voltage Selection Type”,”normalizedValue”:”Auto Voltage”,”value”:”Auto Voltage”},{“name”:”Enclosure Type”,”normalizedValue”:”Outdoor type 3R plastic”,”value”:”Outdoor type 3R plastic”},{“name”:”Resistive Load Ratings”,”normalizedValue”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz”},{“name”:”Packaging Applications”,”normalizedValue”:”Hospitals; Universities; Convenience Stores; Restaurants; Food Storage Warehouses; Food Processing Facilities; Food Service Facilities; Nursing Homes; Medium and Low-Temperature Commercial Refrigeration Systems; Healthcare Facilities”,”value”:”Hospitals; Universities; Convenience Stores; Restaurants; Food Storage Warehouses; Food Processing Facilities; Food Service Facilities; Nursing Homes; Medium and Low-Temperature Commercial Refrigeration Systems; Healthcare Facilities”},{“name”:”Time Initiation”,”normalizedValue”:”Time”,”value”:”Time”},{“name”:”Solutions”,”normalizedValue”:”Refrigeration”,”value”:”Refrigeration”},{“name”:”On Off Operations”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Motor Load Ratings”,”normalizedValue”:”1 HP, 16 FLA, 96 LRA @ 120 VAC; 2 HP, 12 FLA, 72 LRA @ 240 VAC”,”value”:”1 HP, 16 FLA, 96 LRA @ 120 VAC; 2 HP, 12 FLA, 72 LRA @ 240 VAC”},{“name”:”Mechanism Type”,”normalizedValue”:”Electromechanical”,”value”:”Electromechanical”},{“name”:”Wire Size Max”,”normalizedValue”:”#8 AWG”,”value”:”#8 AWG”},{“name”:”Minimum On Off Time”,”normalizedValue”:”15 min”,”value”:”15 min”},{“name”:”Operating Humidity”,”normalizedValue”:”0-95% RH, Non-condensing”,”value”:”0-95% RH, Non-condensing”},{“name”:”Operating Temperature Max”,”normalizedValue”:”104°C”,”value”:”104°C”},{“name”:”Backup Protection Time”,”normalizedValue”:””,”value”:”None”},{“name”:”Applications”,”normalizedValue”:”Walk-in Refrigeration Cooler/Freezer”,”value”:”Walk-in Refrigeration Cooler/Freezer”},{“name”:”Has Captive Trippers CVL”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UL Cerfication File Number”,”normalizedValue”:”#E10694″,”value”:”#E10694″},{“name”:”Input Voltage Ranges”,”normalizedValue”:”120/240 VAC, 60 Hz”,”value”:”120/240 VAC, 60 Hz”},{“name”:”Application Compatibilities”,”normalizedValue”:”Commercial Refrigeration; Walk-in Freezer; Walk-in Cooler”,”value”:”Commercial Refrigeration; Walk-in Freezer; Walk-in Cooler”},{“name”:”LED Defrost Indicator”,”normalizedValue”:”Red”,”value”:”Red”},{“name”:”Time Termination”,”normalizedValue”:”Temperature; Pressure; Time”,”value”:”Temperature; Pressure; Time”},{“name”:”Operating Temperature Min”,”normalizedValue”:”-40°C”,”value”:”-40°C”},{“name”:”Electrical Life”,”normalizedValue”:”50, 000 operations at full load”,”value”:”50, 000 operations at full load”},{“name”:”Switch Type”,”normalizedValue”:”1 SPDT, 1 NC SPST”,”value”:”1 SPDT, 1 NC SPST”},{“name”:”Maximum On Off Time”,”normalizedValue”:”23 hours, 45 min”,”value”:”23 hours, 45 min”},{“name”:”UL Certification”,”normalizedValue”:”cULus”,”value”:”cULus”},{“name”:”Resistive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-240 VAC”,”value”:”40 A, 120-240 VAC”},{“name”:”Mounting Options”,”normalizedValue”:”Bracket”,”value”:”Bracket”},{“name”:”Market”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Operating Temperature Max (°F)”,”normalizedValue”:”104″,”value”:”104″},{“name”:”Has Captive Trippers”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Voltage Range(s)”,”normalizedValue”:”120/240 VAC, 60 Hz”,”value”:”120/240 VAC, 60 Hz”},{“name”:”Features”,”normalizedValue”:”Improved relay performance; Automatically detects and adjusts input voltages (120-240 VAC); Moisture resistant conformal-coated board; Time Initiated, Temperature, Pressure or Time Terminated; Captive trippers are field adjustable to 15-minute intervals; No tools required – snaps into alternative enclosures; Moisture resistant conformal-coated board; LED indicators for defrost and refrigeration cycles; Defrost cycles are programmed independently; Real-time clock face for quick, easy and accurate setting”,”value”:”Improved relay performance; Automatically detects and adjusts input voltages (120-240 VAC); Moisture resistant conformal-coated board; Time Initiated, Temperature, Pressure or Time Terminated; Captive trippers are field adjustable to 15-minute intervals; No tools required – snaps into alternative enclosures; Moisture resistant conformal-coated board; LED indicators for defrost and refrigeration cycles; Defrost cycles are programmed independently; Real-time clock face for quick, easy and accurate setting”},{“name”:”Defrost LED Indicator”,”normalizedValue”:”Red”,”value”:”Red”},{“name”:”Motor Load Ratings Ranges”,”normalizedValue”:”1 HP, 16 FLA, 96 LRA @ 120 VAC; 2 HP, 12 FLA, 72 LRA @ 240 VAC”,”value”:”1 HP, 16 FLA, 96 LRA @ 120 VAC; 2 HP, 12 FLA, 72 LRA @ 240 VAC”},{“name”:”Maximum ON/OFF Times”,”normalizedValue”:”23 hours, 45 min”,”value”:”23 hours, 45 min”},{“name”:”Operating Temperature Min (°F)”,”normalizedValue”:”-40″,”value”:”-40″},{“name”:”Resistive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”},{“name”:”Minimum ON/OFF Times”,”normalizedValue”:”15 min”,”value”:”15 min”},{“name”:”Has Real-time Clock Face”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Series”,”normalizedValue”:”DTAV40″,”value”:”DTAV40″},{“name”:”Current Rating – Maximum”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Defrost Time – Maximum”,”normalizedValue”:”24 hr”,”value”:”24 hr”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”3R”,”value”:”3R”},{“name”:”Standards”,”normalizedValue”:”RoHS, cULus”,”value”:”cULus, RoHS”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Horsepower @ 120V – Maximum”,”normalizedValue”:”1 HP”,”value”:”1 hp”},{“name”:”Defrost Time – Minimum”,”normalizedValue”:”15 min”,”value”:”15 min”},{“name”:”Initiation”,”normalizedValue”:”Time”,”value”:”Time”},{“name”:”Termination”,”normalizedValue”:”Pressure or Temperature or Time”,”value”:”Pressure or Temperature or Time”},{“name”:”Display Type”,”normalizedValue”:”Mechanical”,”value”:”Mechanical”},{“name”:”Contact Form”,”normalizedValue”:”SPST-NC”,”value”:”SPST-NC”},{“name”:”Horsepower @ 240V – Maximum”,”normalizedValue”:”2 HP”,”value”:”2 hp”},{“name”:”AC Voltage Rating”,”normalizedValue”:”120-240V AC”,”value”:”120-240V AC”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”On/Off Cycles – Maximum”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.