Description
[{“name”:”Type”,”normalizedValue”:”BACnet”,”rank”:1,”value”:”BACnet”},{“name”:”Voltage”,”normalizedValue”:”24V AC”,”rank”:2,”value”:”24V AC”},{“name”:”Includes”,”normalizedValue”:”Backplate”,”rank”:3,”value”:”Backplate”},{“name”:”Connection”,”normalizedValue”:”Screw Terminals”,”rank”:4,”value”:”Screw Terminals”},{“name”:”For Use With”,”normalizedValue”:”Fan Coil Units”,”rank”:5,”value”:”Fan Coil Units”},{“name”:”Inputs”,”normalizedValue”:”Thermistors Type II or III”,”rank”:6,”value”:”Thermistors Type II or III”},{“name”:”Outputs”,”normalizedValue”:”Analog/Binary”,”rank”:7,”value”:”Analog/Binary”},{“name”:”Item”,”normalizedValue”:”Controller”,”rank”:8,”value”:”Controller”},{“name”:”Features”,”normalizedValue”:”Suitable for Standalone or BACnet MS/TP Operation, New or Retrofit, Full Color Display, Network Ready”,”value”:”Suitable for Standalone or BACnet MS/TP Operation, New or Retrofit, Full Color Display, Network Ready”},{“name”:”Display”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Agency Compliance”,”normalizedValue”:”UL 916 Energy Management Equipment, FCC Class A, Part 15, Subpart B, Canadian ICES-003 Class B, BACnet Testing Laboratory, SASO PCP Registration KSA R-103274″,”value”:”UL 916 Energy Management Equipment, FCC Class A, Part 15, Subpart B, Canadian ICES-003 Class B, BACnet Testing Laboratory, SASO PCP Registration KSA R-103274″},{“name”:”Dimensions”,”normalizedValue”:”1 in x 1-3/64 in”,”value”:”1 in x 1-3/64 in”},{“name”:”Control Type”,”normalizedValue”:”Push Button”,”value”:”Push Button”},{“name”:”Operating Temperature Range”,”normalizedValue”:”32 to 140 deg F”,”value”:”32 Degrees F to 140 Degrees F”},{“name”:”Dual Transformer Compatible”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Mounting Direction”,”normalizedValue”:”Vertical”,”value”:”Vertical”},{“name”:”Overall Height”,”normalizedValue”:”5-1/8 in”,”value”:”5 1/8 in”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Number of Relay Inputs”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Standards”,”normalizedValue”:”BACnet Testing Laboratory listed, FCC Class A, Part 15, SASO PCP Registration KSA R-103260, Subpart B and complies with Canadian ICES-003 Class B, UL 916 Energy Management Equipment”,”value”:”BACnet Testing Laboratory listed, FCC Class A, Part 15, SASO PCP Registration KSA R-103260, Subpart B and complies with Canadian ICES-003 Class B, UL 916 Energy Management Equipment”},{“name”:”Housing Color”,”normalizedValue”:”White”,”value”:”White”},{“name”:”Application”,”normalizedValue”:”Heat and Cool”,”value”:”Heat and Cool”},{“name”:”Network Protocol Compatibility”,”normalizedValue”:”BACnet MS, TP”,”value”:”BACnet MS/TP”},{“name”:”Temporary Temperature Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Occupancy Sensor”,”normalizedValue”:”Compatible with Occupancy Sensor”,”value”:”Compatible with Occupancy Sensor”},{“name”:”Backlit Type”,”normalizedValue”:”60 Seconds”,”value”:”60 Seconds”},{“name”:”Number of Heating Stages – Heat Pump System”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Temperature Adjustment”,”normalizedValue”:”Floating, Off, On”,”value”:”Floating, On/Off”},{“name”:”Maximum Temperature Control”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Number of Relay Outputs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Dehumidification Control”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Enclosure Color”,”normalizedValue”:”White”,”value”:”White”},{“name”:”Number of Pipes”,”normalizedValue”:”2, 4″,”value”:”2, 4″},{“name”:”Sensor Location”,”normalizedValue”:”Remote”,”value”:”Remote”},{“name”:”Humidification Control”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Temperature Limiting”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Temporary Program Override”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Electrical Connection Type”,”normalizedValue”:”Plug-In”,”value”:”Plug-In”},{“name”:”Number of Heating Stages – Conventional System”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Maximum Operating Humidity”,”normalizedValue”:”90 %”,”value”:”90 %”},{“name”:”Number of Cooling Stages – Heat Pump System”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Temperature Scale”,”normalizedValue”:”Fahrenheit/Celsius”,”value”:”Fahrenheit/Celsius”},{“name”:”Minimum Temperature Control”,”normalizedValue”:”40 deg F”,”value”:”40 Degrees F”},{“name”:”Smart Connectivity”,”normalizedValue”:”No Connectivity”,”value”:”No Connectivity”},{“name”:”Overall Width”,”normalizedValue”:”3-1/2 in”,”value”:”3 1/2 in”},{“name”:”Housing Material”,”normalizedValue”:”Plastic”,”value”:”Plastic”},{“name”:”Minimum Operating Humidity”,”normalizedValue”:”10 %”,”value”:”10 %”},{“name”:”Humidification/Dehumidification Control”,”normalizedValue”:”Yes”,”value”:”Yes, Yes”},{“name”:”Overall Depth”,”normalizedValue”:”1-1/8 in”,”value”:”1 1/8 in”},{“name”:”Programming Capability”,”normalizedValue”:”Not Programmable”,”value”:”Not Programmable”},{“name”:”Amperage”,”normalizedValue”:”1 A”,”value”:”1 A”},{“name”:”Contact Rating”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Changeover Type”,”normalizedValue”:”Automatic and Manual”,”value”:”Automatic and Manual”},{“name”:”Remote Control Functions”,”normalizedValue”:”On/Off and Temperature Control”,”value”:”On/Off and Temperature Control”},{“name”:”Backlit Screen”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Number of Relay Inputs/Outputs”,”normalizedValue”:”0/1″,”value”:”0/1″},{“name”:”Compatible System Type”,”normalizedValue”:”Fan Coil Units”,”value”:”Fan Coil Units”},{“name”:”Display Type”,”normalizedValue”:”Digital”,”value”:”Digital”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.