Description
[{“name”:”Type”,”normalizedValue”:”3 Relay And 6 Universal Outputs With Occupancy Sensor”,”rank”:1,”value”:”3 Relay And 6 Universal Outputs With Occupancy Sensor”},{“name”:”Voltage”,”normalizedValue”:”24V AC”,”rank”:2,”value”:”24V AC”},{“name”:”Includes”,”normalizedValue”:”Backplate”,”rank”:2,”value”:”Backplate”},{“name”:”For Use With”,”normalizedValue”:”AHU, RTU, Heat Pump, Fancoil Unit”,”rank”:3,”value”:”AHU, RTU, Heat Pump, Fancoil Unit”},{“name”:”Connection”,”normalizedValue”:”Wire Clamp 14-22 AWG”,”rank”:3,”value”:”Wire Clamp 14-22 AWG”},{“name”:”Inputs”,”normalizedValue”:”3″,”rank”:4,”value”:”3″},{“name”:”Outputs”,”normalizedValue”:”6″,”rank”:5,”value”:”6″},{“name”:”Agency Compliance”,”normalizedValue”:”UL”,”value”:”UL”},{“name”:”Dimensions”,”normalizedValue”:”5-1/2 x 4-3/16 x 1-1/8″,”value”:”5-1/2 x 4-3/16 x 1-1/8″},{“name”:”Display”,”normalizedValue”:”64 x 128 Pixel Dot Matrix LCD”,”value”:”64 x 128 Pixel Dot Matrix LCD”},{“name”:”Features”,”normalizedValue”:”Advanced Application Library”,”value”:”Advanced Application Library”},{“name”:”Item”,”normalizedValue”:”BACnet Controller”,”value”:”BACnet Controller”},{“name”:”Control Type”,”normalizedValue”:”Push Button”,”value”:”Push Button”},{“name”:”Maximum Operating Humidity”,”normalizedValue”:”95 %”,”value”:”95 %”},{“name”:”Control Output”,”normalizedValue”:”Floating Fan Coil and Zoning, Two RTU/Heat Pump with Optional Economizer”,”value”:”Floating Fan Coil and Zoning, Two RTU/Heat Pump with Optional Economizer”},{“name”:”Standards”,”normalizedValue”:”ANSI/ASHRAE BACnet Standard 135-2008, BACnet Testing Laboratory listed, FCC Class A, Part 15, Subpart B and complies with Canadian ICES-003 Class B, SASO PCP Registration KSA R-103260, UL 916 Energy Management Equipment”,”value”:”ANSI/ASHRAE BACnet Standard 135-2008, BACnet Testing Laboratory listed, FCC Class A, Part 15, Subpart B and complies with Canadian ICES-003 Class B, SASO PCP Registration KSA R-103260, UL 916 Energy Management Equipment”},{“name”:”Number of Poles”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Temperature Sensitivity”,”normalizedValue”:”+/- 0.9 deg F”,”value”:”+/- 0.9 Degrees F”},{“name”:”Mounting Direction”,”normalizedValue”:”Horizontal”,”value”:”Horizontal”},{“name”:”Remote Control Functions”,”normalizedValue”:”Temperature Control”,”value”:”Temperature Control”},{“name”:”Occupancy Sensor”,”normalizedValue”:”Includes Onboard Occupancy Sensor”,”value”:”Includes Onboard Occupancy Sensor”},{“name”:”Amperage”,”normalizedValue”:”1 A”,”value”:”1 A”},{“name”:”Lead Wire Gauge”,”normalizedValue”:”14 ga, 22 ga”,”value”:”14 ga, 22 ga”},{“name”:”Number of Relay Inputs”,”normalizedValue”:”0″,”value”:”0″},{“name”:”Thermostat Type”,”normalizedValue”:”Low Voltage”,”value”:”Low Voltage”},{“name”:”Number of Cooling Stages – Conventional System”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Housing Material”,”normalizedValue”:”Plastic”,”value”:”Plastic”},{“name”:”Number of Relay Inputs/Outputs”,”normalizedValue”:”0/3″,”value”:”0/3″},{“name”:”Display Type”,”normalizedValue”:”Digital”,”value”:”Digital”},{“name”:”Backlit Screen”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Overall Height”,”normalizedValue”:”5-1/2 in”,”value”:”5 1/2 in”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Sensor Length”,”normalizedValue”:”30 ft”,”value”:”30 ft”},{“name”:”Application”,”normalizedValue”:”Heat or Cool”,”value”:”Heat or Cool”},{“name”:”Operating Temperature Range”,”normalizedValue”:”32 to 125 deg F”,”value”:”32 Degrees F to 125 Degrees F”},{“name”:”Number of Heating Stages – Heat Pump System”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Temperature Scale”,”normalizedValue”:”Fahrenheit/Celsius”,”value”:”Fahrenheit/Celsius”},{“name”:”Enclosure Color”,”normalizedValue”:”White”,”value”:”White”},{“name”:”Number of Pipes”,”normalizedValue”:”2, 4″,”value”:”2, 4″},{“name”:”Overall Width”,”normalizedValue”:”4-3/16 in”,”value”:”4 3/16 in”},{“name”:”Minimum Operating Humidity”,”normalizedValue”:”0 %”,”value”:”0 %”},{“name”:”Electrical Connection Type”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Housing Type”,”normalizedValue”:”Flame Retardent Housing”,”value”:”Flame Retardent Housing”},{“name”:”Dehumidification Control”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Number of Heating Stages – Conventional System”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Backlit Type”,”normalizedValue”:”Motion Activated”,”value”:”Motion Activated”},{“name”:”Switch Type”,”normalizedValue”:”SPST”,”value”:”SPST”},{“name”:”Housing Color”,”normalizedValue”:”White”,”value”:”White”},{“name”:”Wireless”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Humidification Control”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”125 deg F”,”value”:”125 Degrees F”},{“name”:”Overall Depth”,”normalizedValue”:”1-1/8 in”,”value”:”1 1/8 in”},{“name”:”Number of Switches”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Sensor Location”,”normalizedValue”:”Remote”,”value”:”Remote”},{“name”:”Number of Cooling Stages – Heat Pump System”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Terminal Designations”,”normalizedValue”:”-A,+B,AO6,AO7,AO8,BO5,COM,DAT,FAN-H,FAN-L,FAN-M,GND,RBO4,RS,WST”,”value”:”-A,+B,AO6,AO7,AO8,BO5,COM,DAT,FAN-H,FAN-L,FAN-M,GND,RBO4,RS,WST”},{“name”:”Number of Relay Outputs”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Sensor Type”,”normalizedValue”:”Thermistor, Type II”,”value”:”Thermistor, Type II”},{“name”:”Humidification/Dehumidification Control”,”normalizedValue”:”No, No”,”value”:”No, No”},{“name”:”Contact Rating”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Screen Height”,”normalizedValue”:”1 1/8 in”,”value”:”1 1/8 in”},{“name”:”Dual Transformer Compatible”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Compatible System Type”,”normalizedValue”:”Air Handling Units, Fan Coil Units”,”value”:”Air Handling Units, Fan Coil Units”},{“name”:”Network Protocol Compatibility”,”normalizedValue”:”BACnet MS, TP”,”value”:”BACnet MS/TP”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.