Control Transformer, 75 VA, Not Rated, 24V AC, 240/480V AC

$104,99

ICT .075KVA 240X480 – 24 F4

Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.

  • • Encapsulated design protects core & coil assembly from potentially damaging contaminants
  • • Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency
  • • Integrally molded terminal blocks with isolation barriers to prevent arc over
  • • Fuse blocks kits available and easily adaptable
  • • Series-parallel connecting links save wiring and labor costs

9999 in stock

SKU: GRG2134449 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Control Transformer”,”rank”:2,”value”:”Control Transformer”},{“name”:”Input Voltage – Transformer”,”normalizedValue”:”240/480V AC”,”rank”:3,”value”:”240/480V AC”},{“name”:”Mounting – Transformer”,”normalizedValue”:”Foot, Plate”,”rank”:7,”value”:”Foot; Plate”},{“name”:”Hz – Electrical”,”normalizedValue”:”50/60 Hz”,”rank”:8,”value”:”50/60 Hz”},{“name”:”Color”,”normalizedValue”:”Black”,”rank”:13,”value”:”Black”},{“name”:”Depth”,”normalizedValue”:”3.82 in”,”value”:”3.82 in”},{“name”:”Phase – Electrical”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Protective Device”,”normalizedValue”:”Primary and Secondary Fuse”,”value”:”Primary and Secondary Fuse”},{“name”:”Enclosure Finish”,”normalizedValue”:”Epoxy Resin Varnish”,”value”:”Epoxy Resin Varnish”},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Width”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Enclosure Style – Transformer”,”normalizedValue”:”Open”,”value”:”Open”},{“name”:”Temp. Rise”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”VA Rating – Transformer”,”normalizedValue”:”75 VA”,”value”:”75 VA”},{“name”:”Output Voltage – Transformer”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Standards”,”normalizedValue”:”cUL Listed, UL Listed”,”value”:”cUL Listed, UL Listed”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”20 yr”,”value”:”20 yr”},{“name”:”Includes”,”normalizedValue”:”Factory Installed Primary Fuse Block and Secondary Fuse Clips”,”value”:”Factory Installed Primary Fuse Block and Secondary Fuse Clips”},{“name”:”Weight”,”normalizedValue”:”3.4 lb”,”value”:”3.4 lb”},{“name”:”Carton Quantity”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Pallet Quantity”,”normalizedValue”:”168″,”value”:”168″},{“name”:”Primary Voltage”,”normalizedValue”:”240 X 480 V”,”value”:”240 X 480 V”},{“name”:”Certified Listed”,”normalizedValue”:”UL ListedcUL Listed”,”value”:”UL ListedcUL Listed”},{“name”:”Features”,”normalizedValue”:”Encapsulated design protects core & coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”,”value”:”Encapsulated design protects core & coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”},{“name”:”Application”,”normalizedValue”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”,”value”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Control Transformer, 75 VA, Not Rated, 24V AC, 240/480V AC”