Description
[{“name”:”Item”,”normalizedValue”:”Control Transformer”,”rank”:2,”value”:”Control Transformer”},{“name”:”Input Voltage – Transformer”,”normalizedValue”:”240/480V AC”,”rank”:3,”value”:”240/480V AC”},{“name”:”Mounting – Transformer”,”normalizedValue”:”Foot, Plate”,”rank”:7,”value”:”Foot; Plate”},{“name”:”Hz – Electrical”,”normalizedValue”:”50/60 Hz”,”rank”:8,”value”:”50/60 Hz”},{“name”:”Color”,”normalizedValue”:”Black”,”rank”:13,”value”:”Black”},{“name”:”Enclosure Finish”,”normalizedValue”:”Epoxy Resin Varnish”,”value”:”Epoxy Resin Varnish”},{“name”:”Depth”,”normalizedValue”:”3.32 in”,”value”:”3.32 in”},{“name”:”Protective Device”,”normalizedValue”:”Primary and Secondary Fuse”,”value”:”Primary and Secondary Fuse”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”20 yr”,”value”:”20 yr”},{“name”:”Width”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Height”,”normalizedValue”:”4.04 in”,”value”:”4.04 in”},{“name”:”VA Rating – Transformer”,”normalizedValue”:”50 VA”,”value”:”50 VA”},{“name”:”Temp. Rise”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Enclosure Style – Transformer”,”normalizedValue”:”Open”,”value”:”Open”},{“name”:”Phase – Electrical”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Output Voltage – Transformer”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Standards”,”normalizedValue”:”cUL Listed, UL Listed”,”value”:”cUL Listed, UL Listed”},{“name”:”Includes”,”normalizedValue”:”Factory Installed Primary Fuse Block and Secondary Fuse Clips”,”value”:”Factory Installed Primary Fuse Block and Secondary Fuse Clips”},{“name”:”Weight”,”normalizedValue”:”2.7 lb”,”value”:”2.7 lb”},{“name”:”Primary Voltage”,”normalizedValue”:”240 X 480 V”,”value”:”240 X 480 V”},{“name”:”Pallet Quantity”,”normalizedValue”:”168″,”value”:”168″},{“name”:”Features”,”normalizedValue”:”Encapsulated design protects core \u0026 coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”,”value”:”Encapsulated design protects core \u0026 coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”},{“name”:”Application”,”normalizedValue”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”,”value”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”},{“name”:”Certified Listed”,”normalizedValue”:”UL ListedcUL Listed”,”value”:”UL ListedcUL Listed”},{“name”:”Carton Quantity”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.