Control Transformer, 50 VA, Not Rated, 120V AC, 208V AC, 277V AC

$94,75

Control Transformer, Input Voltage – Transformer 208V AC, 277V AC, Output Voltage – Transformer 120V AC, VA Rating – Transformer 50 VA, Protective Device None, Enclosure Style – Transformer Open, Mounting – Transformer Foot, Plate, Phase – Electrical 1, Hz – Electrical 50 Hz, 60 Hz, Temp. Rise Not Rated, Enclosure Finish Epoxy Resin Varnish

Out of stock

SKU: GRG4446095 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Control Transformer”,”rank”:2,”value”:”Control Transformer”},{“name”:”Input Voltage – Transformer”,”normalizedValue”:”208V AC, 277V AC”,”rank”:3,”value”:”208V AC, 277V AC”},{“name”:”Output Voltage – Transformer”,”normalizedValue”:”120V AC”,”rank”:4,”value”:”120V AC”},{“name”:”VA Rating – Transformer”,”normalizedValue”:”50 VA”,”rank”:5,”value”:”50 VA”},{“name”:”Phase – Electrical”,”normalizedValue”:”1″,”rank”:6,”value”:”1″},{“name”:”Mounting – Transformer”,”normalizedValue”:”Foot, Plate”,”rank”:7,”value”:”Foot, Plate”},{“name”:”Hz – Electrical”,”normalizedValue”:”50, 60″,”rank”:8,”value”:”50 Hz, 60 Hz”},{“name”:”Temp. Rise”,”normalizedValue”:”Not Rated”,”rank”:14,”value”:”Not Rated”},{“name”:”Height”,”normalizedValue”:”3.78 in”,”rank”:15,”value”:”3.78 in”},{“name”:”Width”,”normalizedValue”:”3 in”,”rank”:16,”value”:”3 in”},{“name”:”Depth”,”normalizedValue”:”3.14 in”,”rank”:17,”value”:”3.14 in”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”20 yr”,”value”:”20 yr”},{“name”:”Item – Transformer”,”normalizedValue”:”Control Transformer”,”value”:”Control Transformer”},{“name”:”Protective Device”,”normalizedValue”:””,”value”:”None”},{“name”:”Standards”,”normalizedValue”:”cUL Listed, UL Listed”,”value”:”cUL Listed, UL Listed”},{“name”:”Enclosure Finish”,”normalizedValue”:”Epoxy Resin Varnish”,”value”:”Epoxy Resin Varnish”},{“name”:”Mounting – Transformer”,”normalizedValue”:”Foot, Plate”,”value”:”Foot, Plate”},{“name”:”Enclosure Style – Transformer”,”normalizedValue”:”Open”,”value”:”Open”},{“name”:”Includes”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Output Voltage”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Input Voltage”,”normalizedValue”:”208V AC, 277V AC”,”value”:”208V AC, 277V AC”},{“name”:”Weight”,”normalizedValue”:”2.7 lb”,”value”:”2.7 lb”},{“name”:”Features”,”normalizedValue”:”Encapsulated design protects core \u0026 coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”,”value”:”Encapsulated design protects core \u0026 coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”},{“name”:”Frequency Rating”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Certified Listed”,”normalizedValue”:”UL ListedcUL Listed”,”value”:”UL ListedcUL Listed”},{“name”:”Application”,”normalizedValue”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encapsulant encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”,”value”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encapsulant encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”},{“name”:”Construction”,”normalizedValue”:”Encapsulated”,”value”:”Encapsulated”},{“name”:”Secondary Voltage”,”normalizedValue”:”120 V”,”value”:”120 V”},{“name”:”Carton Quantity”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Pallet Quantity”,”normalizedValue”:”168″,”value”:”168″},{“name”:”Primary Voltage”,”normalizedValue”:”208/277 V”,”value”:”208/277 V”},{“name”:”Power Rating”,”normalizedValue”:”50 VA”,”value”:”50 VA”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Temperature Rise”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Overall Height”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Enclosure Style”,”normalizedValue”:”Open”,”value”:”Open”},{“name”:”Overall Width”,”normalizedValue”:”2.79 in”,”value”:”2.79 in”},{“name”:”Overall Depth”,”normalizedValue”:”3.23 in”,”value”:”3.23 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Control Transformer, 50 VA, Not Rated, 120V AC, 208V AC, 277V AC”