Description
[{“name”:”Item”,”normalizedValue”:”Control Transformer”,”rank”:2,”value”:”Control Transformer”},{“name”:”Input Voltage – Transformer”,”normalizedValue”:”240/480V AC”,”rank”:3,”value”:”240/480V AC”},{“name”:”Mounting – Transformer”,”normalizedValue”:”Foot, Plate”,”rank”:7,”value”:”Foot; Plate”},{“name”:”Hz – Electrical”,”normalizedValue”:”50/60 Hz”,”rank”:8,”value”:”50/60 Hz”},{“name”:”Color”,”normalizedValue”:”Black”,”rank”:13,”value”:”Black”},{“name”:”Height”,”normalizedValue”:”5.29 in”,”value”:”5.29 in”},{“name”:”Output Voltage – Transformer”,”normalizedValue”:”120/240V AC”,”value”:”120/240V AC”},{“name”:”Enclosure Style – Transformer”,”normalizedValue”:”Open”,”value”:”Open”},{“name”:”Enclosure Finish”,”normalizedValue”:”Epoxy Resin Varnish”,”value”:”Epoxy Resin Varnish”},{“name”:”Standards”,”normalizedValue”:”cUL Listed, UL Listed”,”value”:”cUL Listed, UL Listed”},{“name”:”VA Rating – Transformer”,”normalizedValue”:”200 VA”,”value”:”200 VA”},{“name”:”Width”,”normalizedValue”:”4-1/2 in”,”value”:”4 1/2 in”},{“name”:”Protective Device”,”normalizedValue”:”Primary Fuse”,”value”:”Primary Fuse”},{“name”:”Phase – Electrical”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”20 yr”,”value”:”20 yr”},{“name”:”Temp. Rise”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Depth”,”normalizedValue”:”4.14 in”,”value”:”4.14 in”},{“name”:”Includes”,”normalizedValue”:”Factory Installed 2 Pole Class CC Primary Fuse Block”,”value”:”Factory Installed 2 Pole Class CC Primary Fuse Block”},{“name”:”Weight”,”normalizedValue”:”5.75 lb”,”value”:”5.75 lb”},{“name”:”Features”,”normalizedValue”:”Encapsulated design protects core \u0026 coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”,”value”:”Encapsulated design protects core \u0026 coil assembly from potentially damaging contaminants; Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency; Integrally molded terminal blocks with isolation barriers to prevent arc over”},{“name”:”Carton Quantity”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Primary Voltage”,”normalizedValue”:”240 X 480 V”,”value”:”240 X 480 V”},{“name”:”Certified Listed”,”normalizedValue”:”UL ListedcUL Listed”,”value”:”UL ListedcUL Listed”},{“name”:”Pallet Quantity”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Application”,”normalizedValue”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”,”value”:”Acme’s TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized… without sacrificing secondary voltage stability beyond practical limits.The transformer’s windings and internal terminations are encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Acme’s TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety.”},{“name”:”For Fuse Class”,”normalizedValue”:”CC”,”value”:”CC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.