Control Relay 600Vac 10Amp Iec +Options

$50,39

Control Relay 600Vac 10Amp Iec +Options

9999 in stock

SKU: GRG0847738 Category:

Description

[{“name”:”Coil Volts”,”normalizedValue”:”600VAC”,”rank”:2,”value”:”600VAC”},{“name”:”Item”,”normalizedValue”:”Control Relay 600Vac 10Amp Iec +Options”,”value”:”Control Relay 600Vac 10Amp Iec +Options”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1″,”value”:”EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1″},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Height”,”normalizedValue”:”58 mm”,”value”:”58 mm”},{“name”:”Depth”,”normalizedValue”:”57 mm”,”value”:”57 mm”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”10000 cyc/h”,”value”:”10000 cyc/h”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”24 V AC 50/60 Hz”,”value”:”24 V AC 50/60 Hz”},{“name”:”Product Certifications”,”normalizedValue”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”,”value”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”10 A 50°C”,”value”:”10 A 50°C”},{“name”:”Protective Treatment”,”normalizedValue”:”TC IEC 60068″,”value”:”TC IEC 60068″},{“name”:”Inrush Power In Va”,”normalizedValue”:”30-30 VA 20°C)”,”value”:”30-30 VA 20°C)”},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations contactor open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″,”value”:”vibrations contactor open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″},{“name”:”Pole Contact Composition”,”normalizedValue”:”2 NO + 2 NC”,”value”:”2 NO + 2 NC”},{“name”:”Mounting Support”,”normalizedValue”:”plate || rail”,”value”:”plate || rail”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14″,”value”:”690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14″},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”2 msec”,”value”:”2 ms”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Connections – Terminals”,”normalizedValue”:”spring terminals 1 0.75-1.5 mm²solid || spring terminals 1 0.75-1.5 mm²flexible without cable end”,”value”:”spring terminals 1 0.75-1.5 mm²solid || spring terminals 1 0.75-1.5 mm²flexible without cable end”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”drop-out 0.2…0.75 Uc 50°C) || operational 0.8…1.15 Uc 50°C)”,”value”:”drop-out 0.2…0.75 Uc 50°C) || operational 0.8…1.15 Uc 50°C)”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-50°C”,”value”:”-25-50°C”},{“name”:”Heat Dissipation”,”normalizedValue”:”1.3 to 1.3 W”,”value”:”1.3-1.3 W”},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Irms Rated Making Capacity”,”normalizedValue”:”110 A IEC 60947″,”value”:”110 A IEC 60947″},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 10 MOhm”,”value”:”\u003e 10 MOhm”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m) without derating”,”value”:”6561.68 ft (2000 m) without derating”},{“name”:”Device Short Name”,”normalizedValue”:”CA2K”,”value”:”CA2K”},{“name”:”Non Overlap Distance”,”normalizedValue”:”0.5 mm”,”value”:”0.5 mm”},{“name”:”Mechanical Durability”,”normalizedValue”:”10 Mcycles”,”value”:”10 Mcycles”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG IEC 60947 || 10 A gG VDE 0660″,”value”:”10 A gG IEC 60947 || 10 A gG VDE 0660″},{“name”:”Product Name”,”normalizedValue”:”TeSys CAK”,”value”:”TeSys CAK”},{“name”:”Contactor Application”,”normalizedValue”:”control circuit”,”value”:”control circuit”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102″,”value”:”V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-50-80°C”,”value”:”-50-80°C”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”\u003c= 690 V \u003c= 400 Hz”,”value”:”\u003c= 690 V \u003c= 400 Hz”},{“name”:”Hold-In Power Consumption In Va”,”normalizedValue”:”4.5-4.5 VA 20°C)”,”value”:”4.5-4.5 VA 20°C)”},{“name”:”Operating Time”,”normalizedValue”:”10…20 ms coil de-energisation and NO opening || 10…20 ms coil energisation and NO closing || 15…25 ms coil de-energisation and NC closing || 5…15 ms coil energisation and NC opening”,”value”:”10…20 ms coil de-energisation and NO opening || 10…20 ms coil energisation and NO closing || 15…25 ms coil de-energisation and NC closing || 5…15 ms coil energisation and NC opening”},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Utilisation Category”,”normalizedValue”:”DC-13 || AC-15″,”value”:”DC-13 || AC-15″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Control Relay 600Vac 10Amp Iec +Options”