Description
[{“name”:”Item – Relay”,”normalizedValue”:”Phase Monitor Relay”,”rank”:1,”value”:”Phase Monitor Relay”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”5A @ 250V”,”rank”:3,”value”:”5A @ 250V”},{“name”:”Number of Pins – Relay”,”normalizedValue”:”6″,”rank”:5,”value”:”6″},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail”,”rank”:7,”value”:”DIN Rail”},{“name”:”Standards”,”normalizedValue”:”C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed”,”value”:”C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed”},{“name”:”Housing Material”,”normalizedValue”:”plastic”,”value”:”Plastic”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Overall Height – Relay”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Body Height – Relay”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Item”,”normalizedValue”:”Control Relay”,”value”:”Control Relay”},{“name”:”Input Voltage”,”normalizedValue”:”24 to 240V AC/DC”,”value”:”24 to 240V AC/DC”},{“name”:”Contact Form”,”normalizedValue”:”DPDT”,”value”:”DPDT”},{“name”:”Phase Loss Sensitivity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Body Depth – Relay”,”normalizedValue”:”2.84 in”,”value”:”2.84 in”},{“name”:”Overall Depth”,”normalizedValue”:”2.84 in”,”value”:”2.84 in”},{“name”:”Restart”,”normalizedValue”:”Auto”,”value”:”Auto”},{“name”:”Body Height”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”5 A @ 250V”,”value”:”5 A @ 250V”},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”1,250 VA”,”value”:”1,250 VA”},{“name”:”Flat Pin Width”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Current Rating”,”normalizedValue”:”5 A”,”value”:”5 A”},{“name”:”Base Shape”,”normalizedValue”:”Square”,”value”:”Square”},{“name”:”Body Width”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Body Depth”,”normalizedValue”:”2.84 in”,”value”:”2.84 in”},{“name”:”Restart Time Delay”,”normalizedValue”:”1.5 sec”,”value”:”1.5 sec”},{“name”:”Contact Rating (DC)”,”normalizedValue”:”5 A @ 250V”,”value”:”5 A @ 250V”},{“name”:”Monitored Parameters”,”normalizedValue”:”Overtemperature, Phase Failure, Phase Sequence, Undertemperature”,”value”:”Overtemperature, Phase Failure, Phase Sequence, Undertemperature”},{“name”:”IP Rating”,”normalizedValue”:”IP30″,”value”:”IP30″},{“name”:”Number of Pins”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”30,000,000″,”value”:”30,000,000″},{“name”:”Maximum Switching Current”,”normalizedValue”:”5 A”,”value”:”5 A”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250V AC/DC”,”value”:”250V AC/DC”},{“name”:”Electrical Operating Durability”,”normalizedValue”:”100,000″,”value”:”100,000″},{“name”:”Power Consumption”,”normalizedValue”:”1,250 VA”,”value”:”1,250 VA”},{“name”:”Weight”,”normalizedValue”:”4.64 oz”,”value”:”4.64 oz”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”20.4-264 V AC || 20.4-264 V DC”,”value”:”20.4-264 V AC || 20.4-264 V DC”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”emission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments EN/IEC 61000-6-2″,”value”:”emission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments EN/IEC 61000-6-2″},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”3-phase control relay”},{“name”:”Electrical Durability”,”normalizedValue”:”10000 cycles”,”value”:”10000 cycles”},{“name”:”Overvoltage Category”,”normalizedValue”:”III IEC 60664-1″,”value”:”III IEC 60664-1″},{“name”:”Non-Dissipating Shock Wave”,”normalizedValue”:”4 kV”,”value”:”4 kV”},{“name”:”Run-Up Delay At Power-Up”,”normalizedValue”:”500 msec”,”value”:”500 ms”},{“name”:”Output Contacts”,”normalizedValue”:”2 NO”,”value”:”2 NO”},{“name”:”Relay Monitored Parameters”,”normalizedValue”:”phase sequence || motor temperature via PTC probe || phase failure detection”,”value”:”phase sequence || motor temperature via PTC probe || phase failure detection”},{“name”:”Control Circuit Frequency”,”normalizedValue”:”50…60 Hz +/- 10 %”,”value”:”50…60 Hz +/- 10 %”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals, 1 x 0.5…1 x 4 mm² AWG 20…AWG 11) solid without cable end || screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end || screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 24…AWG 12) flexible with cable end || screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end”,”value”:”screw terminals, 1 x 0.5…1 x 4 mm² AWG 20…AWG 11) solid without cable end || screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end || screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 24…AWG 12) flexible with cable end || screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end”},{“name”:”Switching Capacity In Va”,”normalizedValue”:”1,250 VA”,”value”:”1250 VA”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”400 V IEC 60664-1″,”value”:”400 V IEC 60664-1″},{“name”:”Maximum Resistance”,”normalizedValue”:”1500 Ohm temperature sensor 20°C”,”value”:”1500 Ohm temperature sensor 20°C”},{“name”:”Local Signalling”,”normalizedValue”:”for power ON LED (green) || for phase of relay (R2) LED (yellow) || for temperature of relay (R1) LED (yellow)”,”value”:”for power ON LED (green) || for phase of relay (R2) LED (yellow) || for temperature of relay (R1) LED (yellow)”},{“name”:”Operating Rate”,”normalizedValue”:”\u003c= 360 operations/hour full load”,”value”:”\u003c= 360 operations/hour full load”},{“name”:”Nominal Output Current”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”2 NO”,”value”:”2 NO”},{“name”:”Response Time”,”normalizedValue”:”\u003e 50 ms (input Y1 (contact Y1-T1) and push-button)”,”value”:”\u003e 50 ms (input Y1 (contact Y1-T1) and push-button)”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Maximum Power Consumption In W”,”normalizedValue”:”0.5 W DC”,”value”:”0.5 W DC”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)”,”value”:”IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)”},{“name”:”Mechanical Durability”,”normalizedValue”:”30000000 cycles”,”value”:”30000000 cycles”},{“name”:”Resistance Across Terminals”,”normalizedValue”:”602 mOhm”,”value”:”602 mOhm”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1″,”value”:”0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1″},{“name”:”Relay Type”,”normalizedValue”:”control relay”,”value”:”motor temperature control relay”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Tightening Torque”,”normalizedValue”:”0.6-1 N.m IEC 60947-1″,”value”:”0.6-1 N.m IEC 60947-1″},{“name”:”Shock Resistance”,”normalizedValue”:”15 gn 11 ms IEC 60255-21-1″,”value”:”15 gn 11 ms IEC 60255-21-1″},{“name”:”Voltage Range”,”normalizedValue”:”176…528 V”,”value”:”176…528 V”},{“name”:”Measurement Range”,”normalizedValue”:”208…480 V voltage AC || 0…20 Ohm short-circuit detection”,”value”:”208…480 V voltage AC || 0…20 Ohm short-circuit detection”},{“name”:”Product Certifications”,”normalizedValue”:”GL || UL, GOST || C-tick || CSA”,”value”:”GL || UL || GOST || C-tick || CSA”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1″,”value”:”AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1″},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”24…240 V, \u003c= 3.6 V temperature control circuit T1-T2 terminals open)”,”value”:”24…240 V, \u003c= 3.6 V temperature control circuit T1-T2 terminals open)”},{“name”:”Tripping Threshold”,”normalizedValue”:”3100 Ohm +/- 10 % temperature control circuit”,”value”:”3100 Ohm +/- 10 % temperature control circuit”},{“name”:”Operating Position”,”normalizedValue”:”any position without derating”,”value”:”any position without derating”},{“name”:”Measurement Voltage Limits”,”normalizedValue”:”176 to 528 V AC”,”value”:”176-528 V AC”},{“name”:”Relay Name”,”normalizedValue”:”RM35TM”,”value”:”RM35TM”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || \u003e 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || \u003e 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || \u003e 500 MOhm 500 V DC between supply and relay output IEC 60664-1 || \u003e 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 || \u003e 1 MOhm 500 V DC between supply and measurement IEC 60664-1″,”value”:”\u003e 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || \u003e 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || \u003e 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || \u003e 500 MOhm 500 V DC between supply and relay output IEC 60664-1 || \u003e 500 MOhm 500 V DC between measurement and relay output IEC 60255-5 || \u003e 1 MOhm 500 V DC between supply and measurement IEC 60664-1″},{“name”:”Short-Circuit Current”,”normalizedValue”:”0.007 A temperature sensing circuit T1-T2 terminals short circuited)”,”value”:”0.007 A temperature sensing circuit T1-T2 terminals short circuited)”},{“name”:”Supply Frequency”,”normalizedValue”:”50/60 Hz +/- 10 %”,”value”:”50/60 Hz +/- 10 %”},{“name”:”Power Consumption In Va”,”normalizedValue”:”0-4 VA 24…240 V AC”,”value”:”0-4 VA 24…240 V AC”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60664-1″,”value”:”3 IEC 60664-1″},{“name”:”Dielectric Test Voltage”,”normalizedValue”:”2 kV AC 50 Hz, 1 min”,”value”:”2 kV AC 50 Hz, 1 min”},{“name”:”Time Delay Type”,”normalizedValue”:”fixed 0.3 s”,”value”:”fixed 0.3 s”},{“name”:”Reset Threshold”,”normalizedValue”:”1650 Ohm +/- 10 % temperature control circuit”,”value”:”1650 Ohm +/- 10 % temperature control circuit”},{“name”:”Relative Humidity”,”normalizedValue”:”95-95 % 55-55°C IEC 60068-2-30″,”value”:”95-95 % 55-55°C IEC 60068-2-30″},{“name”:”Width”,”normalizedValue”:”35 mm”,”value”:”35 mm”},{“name”:”Product Specific Application”,”normalizedValue”:”for 3-phase supply”,”value”:”for 3-phase supply”},{“name”:”Reset Time”,”normalizedValue”:”10000 ms output”,”value”:”10000 ms output”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”20 ms 20.4 V”,”value”:”20 ms 20.4 V”},{“name”:”Mounting Support”,”normalizedValue”:”35 mm symmetrical DIN rail conforming to EN/IEC 60715″,”value”:”35 mm symmetrical DIN rail conforming to EN/IEC 60715″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.