Description
[{“name”:”Item”,”normalizedValue”:”Compact smart relay Zelio Logic – \”disco”,”rank”:1,”value”:”Compact smart relay Zelio Logic – \”disco”},{“name”:”Current Rating”,”normalizedValue”:”4 mA”,”rank”:7,”value”:”4 mA”},{“name”:”Power Consumption – Relay”,”normalizedValue”:”6 W”,”value”:”6 W”},{“name”:”Features”,”normalizedValue”:”Local Display; Reverse Polarity Protection”,”value”:”Local Display; Reverse Polarity Protection”},{“name”:”Standards”,”normalizedValue”:”IEC 61000-4-6 level 3, IEC 61000-4-3, IEC 60068-2-27 Ea, IEC 61000-4-11, IEC 61000-4-12, IEC 60068-2-6 Fc, IEC 61000-4-5, IEC 61000-4-2 level 3, IEC 61000-4-4 level 3″,”value”:”IEC 61000-4-6 level 3, IEC 61000-4-3, IEC 60068-2-27 Ea, IEC 61000-4-11, IEC 61000-4-12, IEC 60068-2-6 Fc, IEC 61000-4-5, IEC 61000-4-2 level 3, IEC 61000-4-4 level 3″},{“name”:”Coil Volts”,”normalizedValue”:”24V”,”value”:”24V”},{“name”:”Contact Form – Relay”,”normalizedValue”:”NO Relay Output”,”value”:”NO Relay Output”},{“name”:”Ip Degree of Protection”,”normalizedValue”:”IP20 IEC 60529 terminal block, IP40 IEC 60529 front panel”,”value”:”IP20 IEC 60529 terminal block), IP40 IEC 60529 front panel)”},{“name”:”Cycle Time”,”normalizedValue”:”6-90 ms”,”value”:”6-90 ms”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m)”,”value”:”6561.68 ft (2000 m)”},{“name”:”Lsb Value”,”normalizedValue”:”39 mV analogue input circuit”,”value”:”39 mV analogue input circuit”},{“name”:”Product or Component Type”,”normalizedValue”:”compact discovery packs”,”value”:”compact discovery packs”},{“name”:”Discrete Input Number”,”normalizedValue”:”12 IEC 61131-2 Type 1″,”value”:”12 IEC 61131-2 Type 1″},{“name”:”Current State 1 Guaranteed”,”normalizedValue”:”\u003e= 1.2 mA IB…IG used as discrete input circuit), \u003e= 2.2 mA I1…IA and IH…IR discrete input circuit)”,”value”:”\u003e= 1.2 mA IB…IG used as discrete input circuit), \u003e= 2.2 mA I1…IA and IH…IR discrete input circuit)”},{“name”:”Number or Control Scheme Lines”,”normalizedValue”:”120-120 ladder, 0-200 FBD”,”value”:”120-120 ladder, 0-200 FBD”},{“name”:”Discrete Input Current”,”normalizedValue”:”4 mA”,”value”:”4 mA”},{“name”:”Relative Humidity”,”normalizedValue”:”95-95 % without condensation or dripping water”,”value”:”95-95 % without condensation or dripping water”},{“name”:”Analogue Input Resolution”,”normalizedValue”:”8 bits”,”value”:”8 bits”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”1 msec”,”value”:”1 ms”},{“name”:”Range of Product”,”normalizedValue”:”Zelio Logic”,”value”:”Zelio Logic”},{“name”:”Analogue Input Range”,”normalizedValue”:”0…10 V, 0…24 V”,”value”:”0…10 V, 0…24 V”},{“name”:”Pollution Degree”,”normalizedValue”:”2 IEC 61131-2″,”value”:”2 IEC 61131-2″},{“name”:”Analogue Input Number”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Discrete Input Voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC”},{“name”:”Local Display”,”normalizedValue”:”with”,”value”:”with”},{“name”:”Environmental Characteristic”,”normalizedValue”:”EMC directive IEC 61000-6-2, EMC directive IEC 61000-6-3, EMC directive IEC 61000-6-4, EMC directive IEC 61131-2 zone B, low voltage directive IEC 61131-2″,”value”:”EMC directive IEC 61000-6-2, EMC directive IEC 61000-6-3, EMC directive IEC 61000-6-4, EMC directive IEC 61131-2 zone B, low voltage directive IEC 61131-2″},{“name”:”Input/Output Number”,”normalizedValue”:”20″,”value”:”20″},{“name”:”Backup Time”,”normalizedValue”:”10 years 25°C”,”value”:”10 years 25°C”},{“name”:”Analogue Input Type”,”normalizedValue”:”common mode”,”value”:”common mode”},{“name”:”Power Dissipation In W”,”normalizedValue”:”6 W without extension”,”value”:”6 W without extension”},{“name”:”Clock”,”normalizedValue”:”without”,”value”:”without”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Discrete Input Type”,”normalizedValue”:”resistive”,”value”:”resistive”},{“name”:”Electrical Durability”,”normalizedValue”:”AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1, AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1, DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1, DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1″,”value”:”AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1, AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1, DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1, DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1″},{“name”:”Current State 0 Guaranteed”,”normalizedValue”:”\u003c= 0.5 mA IB…IG used as discrete input circuit)”,”value”:”\u003c= 0.5 mA IB…IG used as discrete input circuit)”},{“name”:”Voltage State 1 Guaranteed”,”normalizedValue”:”\u003e= 15 V I1…IA and IH…IR discrete input circuit, \u003e= 15 V IB…IG used as discrete input circuit”,”value”:”\u003e= 15 V I1…IA and IH…IR discrete input circuit, \u003e= 15 V IB…IG used as discrete input circuit”},{“name”:”Temperature Probe Type”,”normalizedValue”:”NTC 10k 25°C, NTC 1000k 25°C, KTY81 210/220/221/222/250, Pt 500″,”value”:”NTC 10k 25°C, NTC 1000k 25°C, KTY81 210/220/221/222/250, Pt 500″},{“name”:”Reverse Polarity Protection”,”normalizedValue”:”with”,”value”:”with”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”19.2 to 30 V”,”value”:”19.2-30 V”},{“name”:”Disturbance Radiated/Conducted”,”normalizedValue”:”class B EN 55022-11 group 1″,”value”:”class B EN 55022-11 group 1″},{“name”:”Input Compatibility”,”normalizedValue”:”3-wire proximity sensors PNP discrete input”,”value”:”3-wire proximity sensors PNP discrete input”},{“name”:”Number of Outputs”,”normalizedValue”:”8 relay”,”value”:”8 relay”},{“name”:”Counting Frequency”,”normalizedValue”:”1 kHz discrete input”,”value”:”1 kHz discrete input”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”NO relay output”,”value”:”NO relay output”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 2 % 55°C analogue input circuit”,”value”:”+/- 2 % 55°C analogue input circuit”},{“name”:”Input Impedance”,”normalizedValue”:”12 kOhm IB…IG used as analogue input circuit, 12 kOhm IB…IG used as discrete input circuit, 7.4 kOhm I1…IA and IH…IR discrete input circuit”,”value”:”12 kOhm IB…IG used as analogue input circuit, 12 kOhm IB…IG used as discrete input circuit, 7.4 kOhm I1…IA and IH…IR discrete input circuit”},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”24 V”,”value”:”24 V”},{“name”:”Maximum Supply Current”,”normalizedValue”:”100 mA without extension)”,”value”:”100 mA without extension)”},{“name”:”Maximum Altitude Transport”,”normalizedValue”:”3048 m”,”value”:”3048 m”},{“name”:”Kit Composition”,”normalizedValue”:”SR2B201BD, cable PC SR2USB01 for connection to PC”,”value”:”SR2B201BD, cable PC SR2USB01 for connection to PC”},{“name”:”Output Thermal Current”,”normalizedValue”:”8 A for all 8 outputs relay output”,”value”:”8 A for all 8 outputs relay output”},{“name”:”Clock Drift”,”normalizedValue”:”12 min/year 0-55°C, 6 s/month 25-25°C”,”value”:”12 min/year 0-55°C, 6 s/month 25-25°C”},{“name”:”Mechanical Durability”,”normalizedValue”:”10000000 cycles relay output”,”value”:”10000000 cycles relay output”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1″,”value”:”4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1″},{“name”:”Conversion Time”,”normalizedValue”:”smart relay cycle time analogue input circuit”,”value”:”smart relay cycle time analogue input circuit”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) semi-solid, screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) solid, screw terminals, 1 x 0.25…1 x 2.5 mm² AWG 24…AWG 14) flexible with cable end, screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) solid, screw terminals, 2 x 0.25…2 x 0.75 mm² AWG 24…AWG 18) flexible with cable end”,”value”:”screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) semi-solid, screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) solid, screw terminals, 1 x 0.25…1 x 2.5 mm² AWG 24…AWG 14) flexible with cable end, screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) solid, screw terminals, 2 x 0.25…2 x 0.75 mm² AWG 24…AWG 18) flexible with cable end”},{“name”:”Tightening Torque”,”normalizedValue”:”0.5 N.m”,”value”:”0.5 N.m”},{“name”:”Response Time”,”normalizedValue”:”10 ms from state 0 to state 1)relay output, 5 ms from state 1 to state 0)relay output”,”value”:”10 ms from state 0 to state 1)relay output, 5 ms from state 1 to state 0)relay output”},{“name”:”Pvc Free”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Permissible Voltage”,”normalizedValue”:”30 V analogue input circuit”,”value”:”30 V analogue input circuit”},{“name”:”Conversion Error”,”normalizedValue”:”+/- 5 % 25°C analogue input circuit, +/- 6.2 % 55°C analogue input circuit”,”value”:”+/- 5 % 25°C analogue input circuit, +/- 6.2 % 55°C analogue input circuit”},{“name”:”Operating Rate In Hz”,”normalizedValue”:”0.1 Hz at Ie)relay output, 10 Hz no load)relay output”,”value”:”0.1 Hz at Ie)relay output, 10 Hz no load)relay output”},{“name”:”Output Voltage Limits”,”normalizedValue”:”24…250 V AC relay output), 5…30 V DC relay output)”,”value”:”24…250 V AC relay output), 5…30 V DC relay output)”},{“name”:”Switching Capacity In Ma”,”normalizedValue”:”\u003e= 10 mA 12 V relay output)”,”value”:”\u003e= 10 mA 12 V relay output)”},{“name”:”Voltage State 0 Guaranteed”,”normalizedValue”:”\u003c= 5 V I1…IA and IH…IR discrete input circuit, \u003c= 5 V IB…IG used as discrete input circuit”,”value”:”\u003c= 5 V I1…IA and IH…IR discrete input circuit, \u003c= 5 V IB…IG used as discrete input circuit”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-40°C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2, -20-55°C IEC 60068-2-1 and IEC 60068-2-2″,”value”:”-20-40°C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2, -20-55°C IEC 60068-2-1 and IEC 60068-2-2″},{“name”:”Operating Distance”,”normalizedValue”:”10 m between stations, with screened cable (sensor not isolated) analogue input circuit”,”value”:”10 m between stations, with screened cable (sensor not isolated) analogue input circuit”},{“name”:”Overvoltage Category”,”normalizedValue”:”III IEC 60664-1″,”value”:”III IEC 60664-1″},{“name”:”Operating Temp. Range”,”normalizedValue”:”-20-40°C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55°C IEC 60068-2-1 and IEC 60068-2-2″,”value”:”-20-40°C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55°C IEC 60068-2-1 and IEC 60068-2-2″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.