Commercial Electric Tankless Water Heater, General Purpose, 100 Degrees to 140 Degrees F, 480VAC

$16693,99

Electric Tankless Water Heater, Operating Voltage 480V AC, Phase Three, Maximum Flow Rate 40 gpm, Minimum Flow Activation 1 gpm, Overall Height 24 in, Overall Width 30 in, Overall Depth 13.5 in, Power Consumption 48,000 W, Maximum Delivered Temperature 140 Degrees F, Minimum Delivered Temperature 80 Degrees F, Current 58 A, Market Commercial, Industrial, Application Low Duty Cycle, Control Type Digital Display with Keypad, Cord Conductor Gauge 6 AWG Wire, Default Temperature 120 Degrees F

9999 in stock

SKU: GRG3480611 Category:

Description

[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Water Heater Design”,”normalizedValue”:”Point-of-Use”,”rank”:2,”value”:”Point-of-Use”},{“name”:”Min. Flow Activation”,”normalizedValue”:”1 gpm”,”rank”:11,”value”:”1 gpm”},{“name”:”Water Heater Application”,”normalizedValue”:”General Purpose”,”rank”:12,”value”:”General Purpose”},{“name”:”Commercial / Residential”,”normalizedValue”:”Commercial”,”rank”:13,”value”:”Commercial”},{“name”:”Item”,”normalizedValue”:”Electric Tankless Water Heater”,”rank”:15,”value”:”Electric Tankless Water Heater”},{“name”:”Mounting”,”normalizedValue”:”Vertical”,”value”:”Vertical”},{“name”:”Phase”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Temp. Range”,”normalizedValue”:”100 Degrees to 140 Degrees F”,”value”:”100 Degrees to 140 Degrees F”},{“name”:”Temp. Rise @ 20.0 GPM”,”normalizedValue”:”16 Degrees F”,”value”:”16 Degrees F”},{“name”:”Temp. Rise @ 8.0 GPM”,”normalizedValue”:”40 deg F”,”value”:”40 Degrees F”},{“name”:”Amps AC”,”normalizedValue”:”57.8 A”,”value”:”57.8″},{“name”:”Height”,”normalizedValue”:”17-27/64 in”,”value”:”17-27/64\””},{“name”:”Voltage”,”normalizedValue”:”480VAC”,”value”:”480VAC”},{“name”:”Features”,”normalizedValue”:”Fine Tuned Control Board with Temp/Pressure/Flow Algortithm, Speed to Temperature, Low Hysteresis, Low Pressure Drop, Minimal Diagnostics, and Temperature Overshoot, Dry Fire Safety Sensor, Temp Accuracy: +/-1 Degrees at Steady State Flow”,”value”:”Fine Tuned Control Board with Temp/Pressure/Flow Algortithm, Speed to Temperature, Low Hysteresis, Low Pressure Drop, Minimal Diagnostics, and Temperature Overshoot, Dry Fire Safety Sensor, Temp Accuracy: +/-1 Degrees at Steady State Flow”},{“name”:”Default Temperature”,”normalizedValue”:”120 deg F”,”value”:”120 Degrees F”},{“name”:”Elements”,”normalizedValue”:”Lead-Free Replaceable Cartridge Insert”,”value”:”Lead-Free Replaceable Cartridge Insert”},{“name”:”Temp. Rise @ 4.0 GPM”,”normalizedValue”:”81 deg F”,”value”:”81 Degrees F”},{“name”:”Width”,”normalizedValue”:”17-1/8 in”,”value”:”17-1/8\””},{“name”:”Wire Size”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”NEMA Rating”,”normalizedValue”:”4x”,”value”:”4x”},{“name”:”Temp. Rise @ 1.5 GPM”,”normalizedValue”:”218 deg F”,”value”:”218 Degrees F”},{“name”:”Temp. Rise @ 2.5 GPM”,”normalizedValue”:”131 deg F”,”value”:”131 Degrees F”},{“name”:”Depth”,”normalizedValue”:”10-9/32 in”,”value”:”10-9/32\””},{“name”:”Temp. Rise @ 6.0 GPM”,”normalizedValue”:”54 deg F”,”value”:”54 Degrees F”},{“name”:”Standards”,”normalizedValue”:”UL 499, CSA”,”value”:”UL 499, CSA”},{“name”:”Pressure Range”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Water Connection”,”normalizedValue”:”1-1/4\” NPT”,”value”:”1-1/4\” NPT”},{“name”:”Max. Flow Rate”,”normalizedValue”:”40 gpm”,”value”:”40 gpm”},{“name”:”Residential / Commercial”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Overall Height”,”normalizedValue”:”24 in”,”value”:”24 in”},{“name”:”Overall Width”,”normalizedValue”:”30 in”,”value”:”30 in”},{“name”:”Overall Depth”,”normalizedValue”:”13-1/2 in”,”value”:”13.5 in”},{“name”:”Housing Material”,”normalizedValue”:”Stainless Steel”,”value”:”304 Stainless Steel”},{“name”:”Maximum Delivered Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Minimum Flow Activation”,”normalizedValue”:”1 gpm”,”value”:”1 gpm”},{“name”:”Minimum Water Pressure”,”normalizedValue”:”35 psi”,”value”:”35 psi”},{“name”:”Market”,”normalizedValue”:”Commercial, Industrial”,”value”:”Commercial, Industrial”},{“name”:”Maximum Flow Rate”,”normalizedValue”:”40 gpm”,”value”:”40 gpm”},{“name”:”Temperature Rise @ Flow”,”normalizedValue”:”109 Degrees F @ 3 gpm, 11 Degrees F @ 30 gpm, 13 Degrees F @ 26 gpm, 14 Degrees F @ 23 gpm, 16 Degrees F @ 20 gpm, 55 Degrees F @ 6 gpm, 66 Degrees F @ 5 gpm, 82 Degrees F @ 4 gpm”,”value”:”109 Degrees F @ 3 gpm, 11 Degrees F @ 30 gpm, 13 Degrees F @ 26 gpm, 14 Degrees F @ 23 gpm, 16 Degrees F @ 20 gpm, 55 Degrees F @ 6 gpm, 66 Degrees F @ 5 gpm, 82 Degrees F @ 4 gpm”},{“name”:”Element Material”,”normalizedValue”:”Non-Ferrous Metal”,”value”:”Non-Ferrous Metal”},{“name”:”Application”,”normalizedValue”:”Low Duty Cycle”,”value”:”Low Duty Cycle”},{“name”:”Current”,”normalizedValue”:”58 A”,”value”:”58 A”},{“name”:”Cord Conductor Gauge”,”normalizedValue”:”6 AWG Wire”,”value”:”6 AWG Wire”},{“name”:”Maximum Water Pressure”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Control Type”,”normalizedValue”:”Digital Display with Keypad”,”value”:”Digital Display with Keypad”},{“name”:”Water Connection Location”,”normalizedValue”:”Bottom”,”value”:”Bottom”},{“name”:”Minimum Delivered Temperature”,”normalizedValue”:”80 deg F”,”value”:”80 Degrees F”},{“name”:”Energy Factor”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”Operating Voltage”,”normalizedValue”:”480V AC”,”value”:”480V AC”},{“name”:”Power Consumption”,”normalizedValue”:”48,000 W”,”value”:”48,000 W”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Commercial Electric Tankless Water Heater, General Purpose, 100 Degrees to 140 Degrees F, 480VAC”