Commercial Electric Tankless Water Heater, General Purpose, 100 Degrees to 140 Degrees F, 208VAC

$15937,99

Electric Tankless Water Heater, Operating Voltage 208V AC, Phase Three, Maximum Flow Rate 40 gpm, Minimum Flow Activation 1.5 gpm, Overall Height 24 in, Overall Width 30 in, Overall Depth 13.5 in, Power Consumption 54,000 W, Maximum Delivered Temperature 140 Degrees F, Minimum Delivered Temperature 80 Degrees F, Current 150 A, Market Commercial, Industrial, Application Low Duty Cycle, Control Type Digital Display with Keypad, Cord Conductor Gauge 1/0 AWG Wire, Default Temperature 120 Degrees F

Out of stock

SKU: GRG3480550 Category:

Description

[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Water Heater Design”,”normalizedValue”:”Point-of-Use”,”rank”:2,”value”:”Point-of-Use”},{“name”:”Min. Flow Activation”,”normalizedValue”:”1.5 gpm”,”rank”:11,”value”:”1.50 gpm”},{“name”:”Water Heater Application”,”normalizedValue”:”General Purpose”,”rank”:12,”value”:”General Purpose”},{“name”:”Commercial / Residential”,”normalizedValue”:”Commercial”,”rank”:13,”value”:”Commercial”},{“name”:”Item”,”normalizedValue”:”Electric Tankless Water Heater”,”rank”:15,”value”:”Electric Tankless Water Heater”},{“name”:”Depth”,”normalizedValue”:”10-9/32 in”,”value”:”10-9/32\””},{“name”:”Residential / Commercial”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Temp. Rise @ 6.0 GPM”,”normalizedValue”:”61 deg F”,”value”:”61 Degrees F”},{“name”:”Wire Size”,”normalizedValue”:”1/0 AWG”,”value”:”1/0 AWG”},{“name”:”Mounting”,”normalizedValue”:”Vertical”,”value”:”Vertical”},{“name”:”Temp. Rise @ 20.0 GPM”,”normalizedValue”:”18 Degrees F”,”value”:”18 Degrees F”},{“name”:”Max. Flow Rate”,”normalizedValue”:”40 gpm”,”value”:”40 gpm”},{“name”:”Temp. Range”,”normalizedValue”:”100 Degrees to 140 Degrees F”,”value”:”100 Degrees to 140 Degrees F”},{“name”:”Features”,”normalizedValue”:”Fine Tuned Control Board with Temp/Pressure/Flow Algortithm, Speed to Temperature, Low Hysteresis, Low Pressure Drop, Minimal Diagnostics, and Temperature Overshoot, Dry Fire Safety Sensor, Temp Accuracy: +/-1 Degrees at Steady State Flow”,”value”:”Fine Tuned Control Board with Temp/Pressure/Flow Algortithm, Speed to Temperature, Low Hysteresis, Low Pressure Drop, Minimal Diagnostics, and Temperature Overshoot, Dry Fire Safety Sensor, Temp Accuracy: +/-1 Degrees at Steady State Flow”},{“name”:”Water Connection”,”normalizedValue”:”1-1/4\” NPT”,”value”:”1-1/4\” NPT”},{“name”:”Width”,”normalizedValue”:”26-11/64 in”,”value”:”26-11/64\””},{“name”:”Temp. Rise @ 4.0 GPM”,”normalizedValue”:”92 deg F”,”value”:”92 Degrees F”},{“name”:”Elements”,”normalizedValue”:”Lead-Free Replaceable Cartridge Insert”,”value”:”Lead-Free Replaceable Cartridge Insert”},{“name”:”Pressure Range”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Temp. Rise @ 8.0 GPM”,”normalizedValue”:”46 deg F”,”value”:”46 Degrees F”},{“name”:”Temp. Rise @ 2.5 GPM”,”normalizedValue”:”147 deg F”,”value”:”147 Degrees F”},{“name”:”Phase”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Amps AC”,”normalizedValue”:”150 A”,”value”:”150″},{“name”:”Default Temperature”,”normalizedValue”:”120 deg F”,”value”:”120 Degrees F”},{“name”:”Voltage”,”normalizedValue”:”208VAC”,”value”:”208VAC”},{“name”:”NEMA Rating”,”normalizedValue”:”4x”,”value”:”4x”},{“name”:”Standards”,”normalizedValue”:”UL 499, CSA”,”value”:”UL 499, CSA”},{“name”:”Height”,”normalizedValue”:”17-27/64 in”,”value”:”17-27/64\””},{“name”:”Temp. Rise @ 1.5 GPM”,”normalizedValue”:”245 deg F”,”value”:”245 Degrees F”},{“name”:”Overall Depth”,”normalizedValue”:”13-1/2 in”,”value”:”13.5 in”},{“name”:”Overall Width”,”normalizedValue”:”30 in”,”value”:”30 in”},{“name”:”Overall Height”,”normalizedValue”:”24 in”,”value”:”24 in”},{“name”:”Operating Voltage”,”normalizedValue”:”208V AC”,”value”:”208V AC”},{“name”:”Water Connection Location”,”normalizedValue”:”Bottom”,”value”:”Bottom”},{“name”:”Market”,”normalizedValue”:”Commercial, Industrial”,”value”:”Commercial, Industrial”},{“name”:”Minimum Water Pressure”,”normalizedValue”:”35 psi”,”value”:”35 psi”},{“name”:”Maximum Flow Rate”,”normalizedValue”:”40 gpm”,”value”:”40 gpm”},{“name”:”Control Type”,”normalizedValue”:”Digital Display with Keypad”,”value”:”Digital Display with Keypad”},{“name”:”Power Consumption”,”normalizedValue”:”54,000 W”,”value”:”54,000 W”},{“name”:”Element Material”,”normalizedValue”:”Non-Ferrous Metal”,”value”:”Non-Ferrous Metal”},{“name”:”Maximum Water Pressure”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Maximum Delivered Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Temperature Rise @ Flow”,”normalizedValue”:”12 Degrees F @ 30 gpm, 14 Degrees F @ 26 gpm, 16 Degrees F @ 23 gpm, 18 Degrees F @ 20 gpm, 61 Degrees F @ 6 gpm, 74 Degrees F @ 5 gpm, 92 Degrees F @ 4 gpm”,”value”:”12 Degrees F @ 30 gpm, 14 Degrees F @ 26 gpm, 16 Degrees F @ 23 gpm, 18 Degrees F @ 20 gpm, 61 Degrees F @ 6 gpm, 74 Degrees F @ 5 gpm, 92 Degrees F @ 4 gpm”},{“name”:”Minimum Delivered Temperature”,”normalizedValue”:”80 deg F”,”value”:”80 Degrees F”},{“name”:”Housing Material”,”normalizedValue”:”Stainless Steel”,”value”:”304 Stainless Steel”},{“name”:”Application”,”normalizedValue”:”Low Duty Cycle”,”value”:”Low Duty Cycle”},{“name”:”Current”,”normalizedValue”:”150 A”,”value”:”150 A”},{“name”:”Minimum Flow Activation”,”normalizedValue”:”1.5 gpm”,”value”:”1.5 gpm”},{“name”:”Energy Factor”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”Cord Conductor Gauge”,”normalizedValue”:”1/0 AWG Wire”,”value”:”1/0 AWG Wire”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Commercial Electric Tankless Water Heater, General Purpose, 100 Degrees to 140 Degrees F, 208VAC”