Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Clamp Meter w/ NIST”,”rank”:1,”value”:”Clamp Meter w/ NIST”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Safety Rating”,”normalizedValue”:”CAT IV 600V, CAT III 1000V”,”rank”:11,”value”:”CAT III 1000V, CAT IV 600V”},{“name”:”Jaw Opening”,”normalizedValue”:”1.2 in”,”rank”:14,”value”:”1.2 in”},{“name”:”Calibration Frequency”,”normalizedValue”:”10 Hz to 1 kHz; 10 Hz to 50 kHz; 10 to 400 Hz; 50 to 400 Hz”,”rank”:19,”value”:”10 Hz to 1 kHz; 10 Hz to 50 kHz; 10 to 400 Hz; 50 to 400 Hz”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”400 Hz”,”value”:”400 Hz”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-0.70%”,”value”:”+/-0.70%”},{“name”:”Memory”,”normalizedValue”:”Max/Min/Avg”,”value”:”Max/Min/Avg”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Instrument Counts”,”normalizedValue”:”6,000″,”value”:”6,000″},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Dustproof”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Battery Size”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, DC Current, DC Voltage”,”value”:”AC Current, AC Voltage, DC Current, DC Voltage”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-1.00%”,”value”:”+/-1.00%”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp On”,”value”:”Clamp On”},{“name”:”Frequency Counter”,”normalizedValue”:”10 to 400 Hz”,”value”:”10 to 400 Hz”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Standards”,”normalizedValue”:”CE, FCC, UL Listed”,”value”:”CE, FCC, UL Listed”},{“name”:”IP Rating”,”normalizedValue”:”IP40″,”value”:”IP40″},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-22 deg F”,”value”:”-22 Degrees F”},{“name”:”Overall Width”,”normalizedValue”:”3.4 in”,”value”:”3.4 in”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Display Type”,”normalizedValue”:”Backlight LCD”,”value”:”Backlight LCD”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Battery Voltage”,”normalizedValue”:”1.5V”,”value”:”1.5V”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-0.03%”,”value”:”+/-0.03%”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Overall Height”,”normalizedValue”:”1.6 in”,”value”:”1.6 in”},{“name”:”Battery Chemistry”,”normalizedValue”:”Alkaline”,”value”:”Alkaline”},{“name”:”Special Features”,”normalizedValue”:”and relative mode to zero the meter, and thenshare them on the go, Capture the smallest voltage fluctuations when calibrating equipment using themillivolt function, document results, Easily clamp around wires with the generous jaw (30 mm) and ergonomic design, Eliminate errors from residual ghost voltage using LoZ (low impedance) mode, Gain quick insights with Data Hold, Identify trends and anomalies by data logging directly to the internal memory, Min/Max readings, on the ground, or anywhere on a job site, Reduce the Time Needed for Live/Dead Testing with Included 4mm PV Connector Test Leads, Take measurements, View readings right on your mobile device using the CM65’s METERLiNK(R) and the FLIR Tools(R) Mobile app – on the roof”,”value”:”and relative mode to zero the meter, and thenshare them on the go, Capture the smallest voltage fluctuations when calibrating equipment using themillivolt function, document results, Easily clamp around wires with the generous jaw (30 mm) and ergonomic design, Eliminate errors from residual ghost voltage using LoZ (low impedance) mode, Gain quick insights with Data Hold, Identify trends and anomalies by data logging directly to the internal memory, Min/Max readings, on the ground, or anywhere on a job site, Reduce the Time Needed for Live/Dead Testing with Included 4mm PV Connector Test Leads, Take measurements, View readings right on your mobile device using the CM65’s METERLiNK(R) and the FLIR Tools(R) Mobile app – on the roof”},{“name”:”Software Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:”6 kiloohm”,”value”:”6 kiloohm”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-1.50%”,”value”:”+/-1.50%”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”Yes – NIST with Data”,”value”:”Yes – NIST with Data”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”600 A”,”value”:”600 A”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”6 kiloohm”,”value”:”6 kiloohm”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”+/-1.50%”,”value”:”+/-1.50%”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Taiwan, Province of China”,”value”:”Taiwan, Province of China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.